Engineering Papers⌕ Search

Engineering topics

Pozzi, Sara A.

Publications and source records attributed to Pozzi, Sara A..

Application of the Cohn-alpha Method on Bare Highly Enriched Uranium Using Organic Scintillators [Poster]

The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of fragment-correlated γ-ray emission from 252 Cf(sf)

This paper presents recent experimental results on the yield of prompt fission γ rays from the spontaneous fission of 252 Cf. We use an ionization chamber to tag fission events and measure the masses and kinetic energies of the fission fragments and trans-stilbene organic scintillators to measure the neutrons and γ rays emitted by the fission fragments. The combination of the ionization chamber and trans-stilbene scintillators allows us to determine the properties of neutrons and γ rays in coincidence with the fragments. The yield of γ rays is known to be influenced by the angular momenta (AM) of the fission fragments. We present experimental evidence indicating that the total γ-ray multiplicity, i.e., the sum of both fragments' emission, saturates at sufficiently high internal fragment excitation energies. We also observe distinct behaviors for the yield of γ rays from the light and heavy fragments, which for certain mass and total kinetic energy (TKE) regions are weakly or anticorrelated, indicating the presence of complex AM generation modes. We also observed a mass- and TKE-dependent anisotropy of the γ rays, which challenges and expands on the conventional notion that the fragments' AM are always aligned perpendicularly to the fission axis. Furthermore, the dependence of the anisotropy on mass and TKE indicates a dependence of these properties on the specific fission channels, thus providing an insight into the deformations and dynamics in fission and their connection with experimentally observable quantities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma-ray Spectroscopy in Low-Power Nuclear Research Reactors

Gamma-ray spectroscopy is an effective technique for radioactive material characterization, routine inventory verification, nuclear safeguards, health physics, and source search scenarios. Gamma-ray spectrometers typically cannot be operated in the immediate vicinity of nuclear reactors due to their high flux fields and their resulting inability to resolve individual pulses. Low-power reactor facilities offer the possibility to study reactor gamma-ray fields, a domain of experiments hitherto poorly explored. In this work, we present gamma-ray spectroscopy experiments performed with various detectors in two reactors: The EPFL zero-power research reactor CROCUS, and the neutron beam facility at the Ohio State University Research Reactor (OSURR). We employed inorganic scintillators (CeBr3), organic scintillators (trans-stilbene and organic glass), and high-purity germanium semiconductors (HPGe) to cover a range of typical—and new—instruments used in gamma-ray spectroscopy. The aim of this study is to provide a guideline for reactor users regarding detector performance, observed responses, and therefore available information in the reactor photon fields up to 2 MeV. The results indicate several future prospects, such as the online (at criticality) monitoring of fission products (like Xe, I, and La), dual-particle sensitive experiments, and code validation opportunities.

Pakari, Oskari V. (ORCID:0000000337048190)↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary verification of the MCNP perturbation and fixed-source tally sensitivity tools

Integral benchmark experiments are vital in the adjustment and validation of the nuclear data that govern predictive simulations across the nuclear community. The nuclear data sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®) transport code are currently limited; however, expanding sensitivity capabilities will allow benchmark experiments to be designed to resolve compensating errors and adjust nuclear data where previously prohibitively difficult. This paper provides details of a preliminary verification for the use of (i.) the recently revised perturbation and (ii.) developmental fixed-source sensitivity tools within MCNP to calculate sensitivities of tallied responses (such as current integrated over a surface, F1, and flux averaged over a cell, F4) to nuclear data in fixed-source simulations. Energy-binned and energy-integrated sensitivities calculated with these tools are compared against sensitivities calculated using a central-difference approximation. Here, the verification is completed for four configurations of a benchmarked system using a 4.5-kg plutonium sphere surrounded by varying amounts of copper and/or polyethylene. The results show that sensitivities calculated with the perturbation and fixed-source sensitivity tools agree with the central-difference-based approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Examination of Digital-Delay Rossi-$\alpha$ for 252 Cf-Driven Highly Enriched Uranium Using Organic Scintillators

Neutron noise techniques constitute several analysis methods applicable to non-destructive assay. One technique is the Rossi-α method to calculate the prompt neutron decay constant (α) or its inverse, the prompt neutron period (1/α), for assemblies of fissionable material. This work evaluates a high-data-throughput measurement at the National Criticality Experiments Research Center (NCERC) with organic scintillators measuring a subcritical assembly of highly enriched uranium (HEU) metal (93% 235 U). The assembly comprises hemi shells stacked together to form fully closed shells and is driven by a Cf source at the center. The assembly is a total of 59.85 kg HEU and a k eff of 0.99, according to MCNP6.2 KCODE simulations. Measurements were acquired with a three-by-four array of 5.08-cm-diameter by 5.08-cm-length trans-stilbene crystals 166 cm from the assembly center. Two types of coincident binning methods are used to build the Rossi-α distribution of coincident neutron detections: A) type 1 binning, also known as any-and-all forward time differences, and B) type 1 binning with a digital-delay technique that is analogous to Orndoff’s use of delay cabling in early Rossi-alpha measurements. Method B) disregards same-detector coincidences and once all nearest time coincidences are collected between all detectors after a trigger, a time delay of 0.75 µs is implemented. The measured prompt neutron decay constants for both techniques are calculated from single exponential fits and the two methods are compared. Method A) shows an apparent timing discontinuity near 500 ns time differences. This timing discontinuity interferes with the fitting method used to calculate the prompt neutron decay constant. Method B) mitigates the artificial timing discontinuity and removes the disagreement of the fit. Future work will model the time-dependent detector response to discern why this timing discontinuity occurs, discern how Method B) reduces the amplitude of this timing discontinuity, and apply this method to critical assembly measurements to ultimately confirm the recommendation to use Method B) for high-data-throughput measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Photoneutrons from Depleted Uranium and Comparison Study Using MCNPX-PoliMi

High-energy photon interrogation is a nondestructive technique that is used to detect special nuclear materials and characterize nuclear waste. The development of such systems is complex and requires Monte Carlo simulations to optimize system performance. Monte Carlo simulations rely on various scattering, absorption, and photonuclear cross-section data. While the scattering and absorption cross-section data have been extensively studied and validated with experiments, the results obtained from photonuclear simulations are often found to underpredict measured results, indicating uncertainties in the photonuclear cross sections themselves. Thus, there is a need for new measured results that can be used to quantify underpredictions in simulations using photonuclear cross-section data. In the present work, we interrogated depleted uranium with a 9-MV electron linac and detected photoneutrons with trans-stilbene organic scintillators. The measurement of photoneutrons with organic scintillators is challenging due to the presence of the intense photon flux, which causes issues such as pulse pile-up, detector saturation, and poor signal-to-background ratio. To mitigate these challenges, we used iron and polyethylene shielding of varying thicknesses around the depleted uranium target and a neural network–based digital pulse processing algorithm to recover neutron and photon information from piled-up events. Our goal was to compare the measured photoneutron count rate with the simulated rate obtained using the MCNPX-PoliMi transport code. For a light output window of 0.28 to 2.67 MeVee (1.66- to 6.85-MeV proton recoil energy), we found that the simulated count rate obtained using the ENDF/B-VII photonuclear cross-section library underpredicts the measured rate by 32.8% 3.2%. Additionally, we compared the simulated and measured photoneutron light output distributions. For the least thicknesses of shielding, the simulation was found to underpredict measurements in the 0.70- to 2.67-MeVee light output window. For the greatest thicknesses of shielding, the simulation was found to underpredict the measurement across the entire light output window of 0.28 to 2.67 MeVee.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Correlations between energy and $\gamma$-ray emission in 239 Pu($n, f$)

Here, we study $\gamma$-ray emission following $^{239}\mathrm{Pu}(n,\mathrm{f})$ over an incident neutron energy range of $2 < E_i < 40$ MeV. We present the first experimental evidence for positive correlations between the total angular momentum generated in fission and the excitation energy of the compound nucleus prior to fission. The $\gamma$-ray multiplicity increases linearly with incident energy below the 2\textsuperscript{nd}-chance fission threshold with a slope of $0.085 \pm 0.010$~MeV$^{-1}$. This linear trend appears to hold for the average excitation energy of the compound nucleus between $9 < \langle E_x \rangle < 19$ MeV. Most of the multiplicity increase comes from an enhancement around a $\gamma$-ray energy of 0.7 MeV, which we interpret as stretched quadrupole $\gamma$ rays that indicate an increase in total fission-fragment angular momentum with excitation energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating List-Mode Data Sensitivities to Nuclear Data with MCNP6

Nuclear data are a vital component of predictive simulations used in applications like experiment design, stockpile stewardship, nuclear nonproliferation/safeguards, health physics, and criticality safety. A singular simulation requires the coalescence of different areas of nuclear data such as cross sections, angular distributions, and energy distributions of emitted neutrons for different materials and energy ranges. Improving nuclear data and thus reducing the uncertainty in simulated parameters could enable smaller, better-informed safety factors and ultimately reduce operational and procedural costs. There is a constant effort to garner a better understanding of the physical quantities represented by nuclear data through experiments. Integral experiment benchmarks use simulated and measured results to validate current nuclear data values. In the past, benchmarks primarily focused on the effective multiplication factor (k eff ); however, this limited scope has caused compensating errors and areas of nuclear data that lack validation. Compensating errors are inaccuracies in nuclear data that are obfuscated by cancellation when observing integrated values such as k eff . Diverse integral benchmark experiments that look for quantities of interest other than k eff and include multiple responses minimize the possibility of compensating errors and provides validation to areas of nuclear data previously lacking experimental validation. Benchmark experiments can be optimized during the design process to be highly dependent on specific areas of nuclear data. The dependence of a response in an experiment to a specific area/type of nuclear data is defined as sensitivity. A larger sensitivity means that nuclear data uncertainties will play a larger role in the response(s) resulting in larger bias. Currently, the sensitivity capabilities of the Monte Carlo N-Particle (MCNP ®1 ) transport code are limited to responses of k eff and tallied values (e.g., flux, surface current). As a part of the EUCLID project, this work explores estimating list-mode nuclear data sensitivities that can be used to design experiments aimed to constrain and reduce compensating errors in nuclear data by focusing on responses other than k eff . Tallied values are ideal quantities that are estimated with detectors during experiments. List-mode data (a list of neutron collection times) are the direct output of detector systems in subcritical neutron noise experiments. Expanding MCNP sensitivity capabilities to include the sensitivity of responses estimated from list-mode data, such as the prompt neutron decay constant (α) and multiplicity estimates (S and D), enables more direct comparison of simulated and measured experimental quantities. Additionally, deterministic tools such as SENSMG are capable of obtaining sensitivities to a wide variety of responses; however, these tools cannot handle complex geometries due to the assumptions made in discretizing the phase-space variables of the Boltzman transport equation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗