Recommendations for harmonized reporting of radiation Dosimetry by adoption of Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER)

Here, in radiobiology, radiation physics, and related areas, there is growing interest in transitioning from cesium-based irradiators to X-ray technologies. Therefore, it makes it imperative for reproducibility purposes, for researchers to provide specifications regarding device parameters, machine calibration details, and experimental setup when innovative X-ray technology is being employed. Several groups have already identified a glaring lack in completeness of critical information on experimental setups, equipment, and physical parameters in published radiation biology studies. The Alternative Technologies Meta Study Report by Brookhaven National Laboratory (BNL) examined 456 manuscripts published between 2017-2021. Only 64 of the reviewed studies (14.0%) consistently reported methods that could allow for replication of their studies. However, 85% provided information on the manufacturer, the irradiator model and the absorbed radiation dose. Approximately 66% provided information on the energy spectra and the dose rate, but only one third disclosed the filter used. Less than 15% of the reviewed studies reported information on calibration and field geometry, specifically field size and distance from source, which are critical parameters in determining the absorbed radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

General Overview of Mobile Sources Used for Well Logging and Industrial Radiography Applications

Mobile sources is a term most commonly used to describe radioactive sources that are used in applications requiring frequent transportation. Such radioactive sources are in common use world-wide where typical applications include radiographic non-destructive evaluation (NDE) and oil and gas well logging, among others requiring lesser amounts of radioactivity. This report provides a general overview of mobile sources used for well logging and industrial radiography applications including radionuclides used, equipment, and alternative technologies. Information presented here has been extracted from a larger study on common mobile radiation sources and their use.

47 OTHER INSTRUMENTATION↗

Modeling Cell Survival Fraction and Other Dose-Response Relationships for Immunodeficient C.B-17 SCID Mice Exposed to 320-kV X Rays

US homeland security concerns related to potential misuse of γ-ray-emitting radiation sources employed in radiobiological research (eg, shielded cesium-137 irradiators) led to recommendations by the National Research Council to conduct studies into possibly replacing γ-ray irradiators used in research involving small rodent and other models with X-ray instruments. A limiting factor is suitability of the X-ray photon energy spectra. The objective of our research was to demonstrate the suitability of the radiation energy spectrum of 320-kV X rays after filtration (HVL = 4 mm Cu) for in-vivo cytotoxicity studies in immunodeficient C.B-17 SCID mice. By using a previously-published Hazard Function (HF) model to characterize dose-response relationships for in vivo bone marrow and spleen cell survival fractions and also to characterize the acute lethality risk (hematopoietic syndrome mode) we demonstrate that the filtered 320-kV X-ray beam appears suitable for such studies. A key finding for C.B-17 SCID mice when compared to results previously obtained for immunocompetent C.B-17 mice is that the immunodeficient mice appear to be more radioresistant, implicating a possible role of the immune system capacity in radiosensitivity of mammals.

Scott, Bobby R.↗

Radiobiological Studies Using Cs-137 Gamma or 320 kV X Rays

There are numerous self-shielded research irradiators used in various facilities throughout the United States. The irradiators employ radioactive sources containing either 137 Cs or 60 Co and the irradiators are used for a variety of radiobiological investigations involving cellular and/or animal models. A report from the National Academy of Sciences described security issues associated with particular radiation sources and the desire for their replacement with suitable X-ray irradiators. One possible replacement would be a 320 kV X-ray irradiator. The participants in this research successfully performed in vivo radiobiological studies involving mice exposed to filtered (HVL ≈ 4 mm Cu) 320 kV X rays. Two publications (one published and one submitted at the publishing of this report) documenting key findings are provided in Appendices A and B of this report. The 320 kV X rays were found suitable for in vivo (in mice) cell survival studies and are expected to be suitable for bone marrow transplantation studies using mice but this needs to be experimentally validated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Cs-137 γ Rays and 320-kV X-Rays in a Mouse Bone Marrow Transplantation Model

US homeland security concerns regarding the potential misuse of some radiation sources used in radiobiological research, for example, cesium-137 ( 137 Cs), have resulted in recommendations by the National Research Council to conduct studies into replacing these sources with suitable X-ray instruments. The objective of this research is to compare the effectiveness of an X-RAD 320 irradiator (PXINC 2010) with a 137 Cs irradiator (Gammacell-1000 Unit) using an established bone marrow chimeric model. Using measured radiation doses for each instrument, we characterized the dose–response relationships for bone marrow and splenocyte ablation, using a cytotoxicity-hazard model. Our results show that the X-RAD 320 photon energy spectrum was suitable for ablating bone marrow at the 3 exposure levels used, similar to that of 137 Cs photons. However, the 320-kV X-rays were not as effective as the much higher energy γ rays at depleting mouse splenocytes. Furthermore, the 3 X-ray levels used were less effective than the higher energy γ rays in allowing the successful engraftment of donor bone marrow, potentially as a result of the incomplete depletion of the spleen cells. More defined studies are warranted for determining whether bone marrow transplantation in mice can be successfully achieved using 320-kV X-rays. A higher X-ray dose then used is likely needed for transplantation success.

320-kV X-rays↗