Miniaturized physiological data telemetry system

Portable digital physiological data telemetry system uses less power, is more compact, and provides better data integrity than two previous systems designed to similar specifications. It has 13 data channels and two-way voice communication.

Portnoy, W. M.

Reliability study of refractory gate gallium arsenide MESFETS

Refractory gate MESFET's were fabricated as an alternative to aluminum gate devices, which have been found to be unreliable as RF power amplifiers. In order to determine the reliability of the new structures, statistics of failure and information about mechanisms of failure in refractory gate MESFET's are given. Test transistors were stressed under conditions of high temperature and forward gate current to enhance failure. Results of work at 150 C and 275 C are reported.

Yin, J. C. W.

A miniaturized digital telemetry system for physiological data transmission

A physiological date telemetry system, consisting basically of a portable unit and a ground base station was designed, built, and tested. The portable unit to be worn by the subject is composed of a single crystal controlled transmitter with AM transmission of digital data and narrowband FM transmission of voice; a crystal controlled FM receiver; thirteen input channels follwed by a PCM encoder (three of these channels are designed for ECG data); a calibration unit; and a transponder control system. The ground base station consists of a standard telemetry reciever, a decoder, and an FM transmitter for transmission of voice and transponder signals to the portable unit. The ground base station has complete control of power to all subsystems in the portable unit. The phase-locked loop circuit which is used to decode the data, remains in operation even when the signal from the portable unit is interrupted.

Portnoy, W. M.

Electrocardiogram signal analyzer

Algorithm based on Taylor series expansion of Fourier transform has been developed and used for detection of cardiac arrhythmias in real-time electrocardiogram signal.

Portnoy, W. M.

A multichannel physiological data/voice telemetry system

A seven channel physiological telemetry system was designed, constructed, and tested for a space environment to transfer physiological and voice information to and from an astronaut. Three ECG leads were monitored simultaneously, and two-way voice communication was achieved. The portable unit operated properly under ground based station (GBS) control. The major design problem was associated with the constraints of a wide bandwidth FM transmitter with crystal control combined with the tri-state logic format used. However, by using an ''indirect FM'' scheme and incorporating additional waveshaping circuits at the GBS, proper operation of the system was obtained. In the present form, the telemetry system has capability for seven channels of low level (2.5 mv peak maximum) physiological signals with bandwidths between 0.03 Hz and 100 Hz. Additional signal conditioning and modification of the instrumentation amplifier gains are required for other signals.

Portnoy, W. M.

Insulated ECG electrodes

Insulated, capacitively coupled electrode does not require electrolyte paste for attachment. Other features of electrode include wide range of nontoxic material that may be employed for dielectric because of sputtering technique used. Also, electrode size is reduced because there is no need for external compensating networks with FET operational amplifier.

Portnoy, W. M.

The development of insulated electrocardiogram electrodes

An integrated system was developed, consisting of an insulated electrode and an impedance transformer, which can be used for the acquisition of electrocardiographic data. The electrode consists of a thin layer of dielectric material deposited onto a silicon substrate. The impedance transformer is an operational amplifier used in the unity gain configuration. Both electrode and impedance transformer are contained in a plastic housing identical to that used with the NASA Apollo-type electrode. The lower cut off frequency of the electrode system is between 0.01 and 1.0 Hz, depending on the dielectric used and its thickness. Clinical quality electrocardiograms were obtained with these electrodes.

Portnoy, W. M.