Closed form expressions for crack mouth displacements and stress intensity factors for chevron notched short bar and short rod specimens based on experimental compliance measurements

A set of equations are presented describing certain fracture mechanics parameters for chevron notch bar and rod specimens. They are developed by fitting compliance calibration data reported earlier. The equations present the various parameters in their most useful forms. The data encompass the entire range of the specimen geometries most commonly used. Their use will facilitate the testing and analysis of brittle metals, ceramics, and glasses.

Bubsey, R. T.

Compliance calibration of the short rod chevron-notch specimen for fracture toughness testing of brittle materials

The short rod chevron-notch specimen has the advantages of (1) crack development at the chevron tip during the early stage of test loading, and (2) convenient calculation of plane-strain fracture toughness from the maximum test load and from a calibration factor which depends only on the specimen geometry and manner of loading. For generalized application, calibration of the specimen over a range of specimen proportions and chevron-notch configurations is necessary. Such was the objective of this investigation, wherein calibration of the short rod specimen was made by means of experimental compliance measurements converted into dimensionless stress intensity factor coefficients.

Bubsey, R. T.

Fracture toughness of brittle materials determined with chevron notch specimens

Short bar, short rod, and four-point-bend chevron-notch specimens were used to determine the plane strain fracture toughness of hot-pressed silicon nitride and sintered aluminum oxide brittle ceramics. The unique advantages of this specimen type are: (1) the production of a sharp natural crack during the early stage of test loading, so that no precracking is required, and (2) the load passes through a maximum at a constant, material-independent crack length-to-width ratio for a specific geometry, so that no post-test crack measurement is required. The plane strain fracture toughness is proportional to the maximum test load and functions of the specimen geometry and elastic compliance. Although results obtained for silicon nitride are in good mutual agreement and relatively free of geometry and size effects, aluminum oxide results were affected in both these respects by the rising crack growth resistance curve of the material.

Shannon, J. L., Jr.

LVDT gage for fracture-toughness tests in liquid hydrogen

Linear-variable differential transformer replaces conventional resistance strain gages to measure crack-mouth-opening displacement. LVDT is superior in tests under liquid hydrogen, where boiling of hydrogen on resistive is suited to broad temperature range and hostile environments such as nuclear reactors.

Pierce, W. S.

Tension-mode loading for bend specimens in cryogens

Special fixture permits use of tension-loading apparatus in fracture-toughness tests on standard bend specimens. Specimen is held in place by spacer blocks and wire clips. Central, load-application roller bends specimen between lateral, reaction-load rollers.

Pierce, W. S.

Modified displacement gage for cryogenic testing

Modification of double-cantilever-beam resistance strain gage makes boiling of hydrogen on gage arms less of problem. Modified gages are encapsulated nickel/chromium alloy, and bridge-excitation voltage is reduced from 10 to 1.5 volts. Sensitivity is 1.0 millivolt per inch with 1.5 volt excitation.

Pierce, W. S.

Resonant-fatigue cracking apparatus

Apparatus produces controlled surface cracks in test specimens. It has been developed and is useful in production of surface cracks of controlled size and shape in fracture specimens. It consists of specially-designed stand-mounted clamping fixture, commercially available pneumatic actuator, and suitable sound-control mufflers.

Dorner, J. P.

Fracture toughness of brittle materials determined with chevron notch specimens

The use of chevron-notch specimens for determining the plane strain fracture toughness (K sub Ic) of brittle materials is discussed. Three chevron-notch specimens were investigated: short bar, short rod, and four-point-bend. The dimensionless stress intensity coefficient used in computing K sub Ic is derived for the short bar specimen from the superposition of ligament-dependent and ligament-independent solutions for the straight through crack, and also from experimental compliance calibrations. Coefficients for the four-point-bend specimen were developed by the same superposition procedure, and with additional refinement using the slice model of Bluhm. Short rod specimen stress intensity coefficients were determined only by experimental compliance calibration. Performance of the three chevron-notch specimens and their stress intensity factor relations were evaluated by tests on hot-pressed silicon nitride and sintered aluminum oxide. Results obtained with the short bar and the four-point-bend specimens on silicon nitride are in good agreement and relatively free of specimen geometry and size effects within the range investigated. Results on aluminum oxide were affected by specimen size and chevron-notch geometry, believed due to a rising crack growth resistance curve for the material. Only the results for the short bar specimen are presented in detail.

Shannon, J. L., Jr.

Surface-crack shape change in bending fatigue using an inexpensive resonant fatiguing apparatus

An inexpensive device for producing surface cracks of controlled size and shape is described along with results of its use which show how the shape of the surface crack changes as it grows in bending fatigue from a variety of crack starter shapes. The growth pattern for any crack is uniquely defined by the crack starter configuration and appears to be independent of alloy. Shape changes are substantial and all growth curves tend toward a common growth curve. Circular cracks tend to become elliptical with an associated increase in stress intensity factor. This increase accelerates the crack growth rate and proximity to the critical flaw size. Through-cracks produced by the extension of a surface crack in a bending stress field will have length ten times the section thickness. The results demonstrate the necessity of taking into account changing crack shape in the calculation of structural life when bending is a significant component of the stress field.

Pierce, W. S.

The influence of composition, annealing treatment, and texture on the fracture toughness of Ti-5Al-2.5Sn plate at cryogenic temperatures

The plane strain fracture toughness K sub Ic and conventional tensile properties of two commercially produced one-inch thick Ti-5Al-2.5Sn plates were determined at cryogenic temperatures. One plate was extra-low interstitial (ELI) grade, the other normal interstitial. Portions of each plate were mill annealed at 1088 K (1500 F) followed by either air cooling or furnace cooling. The tensile properties, flow curves, and K sub Ic of these plates were determined at 295 K (room temperature), 77 K (liquid nitrogen temperature), and 20 K (liquid hydrogen temperature).

Vanstone, R. H.