Engineering Papers⌕ Search

Engineering topics

Phillips, Mark C.

Publications and source records attributed to Phillips, Mark C..

At least 37 records · Page 2

Early- and late-time dynamics of laser-produced plasmas by combining emission and absorption spectroscopy

Optical emission spectroscopy and laser absorption spectroscopy are two highly complementary techniques for diagnosing plasmas, specifically in the determination of important parameters such as temperature and density. In this work, we characterized a laser-produced plasma by combining emission and tunable absorption spectroscopy. Plasmas are produced by focusing pulses from a frequency quadrupled Nd:YAG laser onto a glass target containing a minor concentration of aluminum in an ambient atmosphere of ~100 Torr N 2 . Here, emission spectroscopy is used to investigate the line behavior of Al and Ca, electron density, and excitation temperature at times = 5 μs, while absorption spectroscopy is used to investigate the line behavior of Al and Ca, species density, and kinetic temperature at times = 5-100 μs. A comparison is made between the excitation temperature measured from emission using the Boltzmann plot method and the kinetic temperature measured from absorption; the implications of this comparison on local thermodynamic equilibrium and line-of-sight averaging are discussed. By combining the two methods of optical emission and laser absorption spectroscopy, a comprehensive characterization of the plasma over the entire lifetime of its evolution is possible, leading to a greater understanding of the plasma behavior including particle condensation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toroidal multipass absorption device

A toroidal optical device can include a ring mirror defining a toroidal optical cavity symmetric about an axis and an optical coupler situated inside the toroidal optical cavity. The optical coupler can be situated to direct an input light first received from outside the toroidal optical cavity propagating inside the toroidal optical cavity, to multiply reflect from the ring mirror inside the toroidal optical cavity. A method includes producing one or more additional ring mirrors defining a toroidal optical cavity symmetric about a sagittal axis using a first ring mirror as a master form, and affixing an optical coupler inside the optical cavity to at least one of the one or more additional ring mirrors.

Bernacki, Bruce E.↗

Burst-mode dual-comb spectroscopy

We introduce a new modality of dual-comb spectroscopy that enables a simplified and powerful new approach for time-resolved measurements with increased acquisition rates. This "burst mode" form of dual-comb spectroscopy (BM-DCS) relies on the multiplexing of each probe pulse into a short train of pulses. With this approach we demonstrate a time-resolved series of absorption-based spectroscopic measurements of a laser-induced plasma using only a single laser ablation shot and identify 22 Nd lines not previously reported in the literature. The transmission spectra spanned 3.1 THz and were acquired at an effective acquisition rate of 25 kHz with 40 ms time-resolution. This simple modification to 100 MHz level dual-comb systems provides a flexible approach for studying transient and low duty-cycle events such as laser-induced plasmas, combustion, and explosive reactions.

(280.5395) Plasma Diagnostics, broadband laser spe↗

Time-resolved absorption spectroscopic characterization of ultrafast laser-produced plasmas under varying background pressures

Time-resolved tunable laser absorption spectroscopy is used to characterize the physical properties of ultrafast laser-produced plasmas. The plasmas were produced from an Inconel target, with = 0.4 wt. % Al, using ~ 35 fs, ~800 nm laser pulses at varying Ar background pressures from 1-100 Torr. The absorption spectrum of atomic Al is measured with high spectral and temporal resolution when the probe laser is stepped across the selected Al transition at 394.4 nm. Spectral fitting is used to infer linewidths, kinetic temperature, Al column density, and pressure broadening coefficient. The late time physical properties of plasmas are compared for various pressure levels. Our studies highlight that a significant lower state population exists even at early times of ultrafast laser-produced plasma evolution and lower state population persistence decreases with increasing ambient pressure. We also show that the fundamental optical properties, such as pressure-broadening, can be measured using ultrafast laser-produced plasmas combined with laser absorption spectroscopy.

laser absorption spectroscopy, laser produced plas↗

Standoff detection of chemical plumes from high explosive open detonations using a swept-wavelength external cavity quantum cascade laser

A swept-wavelength external cavity quantum cascade laser (ECQCL) is used to perform standoff detection of combustion gases in a plume generated from an outdoor high-explosive (HE) open detonation. The swept-ECQCL system was located at a standoff distance of 830 m from a 41kg charge of LX-14(polymer-bonded high explosive) and was used to measure the infrared transmission/absorption through the post-detonation plume as it propagated through the beam path. The swept-ECQCL was operated continuously to record broadband absorption spectra at 200hz rate over a spectral range from 2050 to 2230 cm -1 (4.48 - 4.88 μm). Fitting of measured spectra was used to determine time-resolved column densities of CO, CO 2 , H 2 O, and N 2 O. Analysis of visible video imagery was used to provide timing correlations and to estimate plume dimensions, from which gas mixing ratios were estimated. Measured emission factors and modified combustion efficiency show good agreement with previously reported values.

47 OTHER INSTRUMENTATION↗

Unraveling Spatio-Temporal Chemistry Evolution in Laser Ablation Plumes and Its Relation to Initial Plasma Conditions

The chemistry evolution in a laser ablation plume depends strongly on its initial physical conditions. In this article, we investigate the impact of plasma generation conditions on the interrelated phenomena of expansion dynamics, plasma chemistry, and physical conditions. Plasmas are produced from a uranium metal target in air using nanosecond, femtosecond, and femtosecond filament-assisted laser ablation. Time-resolved two-dimensional spectral imaging was performed for evaluating the spatio-temporal evolu-tion of atoms, diatoms, polyatomic molecules, and nanoparticles in situ. Emission spectral features reveal that molecular formation occurs at early times in both femtosecond and filament ablation plumes, although with different temporal decay. In contrast, mo-lecular formation is found to occur at much later times in nanosecond plasma evolution. Spectral modeling is used to infer tem-poral behavior of plasma excitation temperature, and results highlighted that nanosecond plume temperatures decay rapidly while plumes generated by filament ablation show slowest decay. In this work, we find U atoms and UO molecules co-exist in ultrafast laser produced plasmas even at early times after plasma onset owing to favorable temperatures for molecular formation. Regardless of irradiation conditions, plume emission features showed presence of higher oxides (i.e. UxOy), although with different temporal histories. Our study provides insight into the impact of plasma generation conditions on chemistry evolution in plasmas produced from traditional focused femtosecond, nanosecond, and filament-assisted laser ablation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of ambient gas confinement, plasma chemistry, and focusing conditions on emission features of femtosecond laser-produced plasmas

Ultrafast laser ablation coupled with optical emission spectroscopy is currently under development for standoff detection of elements and their isotopes for a wide range of application areas. In this work, we explore the role of ambient air pressure during the interaction of an ultrafast laser beam with two metallic targets (brass and uranium) with significantly different oxygen gas-phase reactivity. Plasma plumes were generated by focusing ~800 nm, ~35 fs pulses from an ultrafast laser system using a long focal length lens with f = 1 m. Two-dimensional spectral imaging was performed over the pressure range of 30 mTorr-700 Torr air to evaluate emission dynamics, plasma chemistry, signal-to-background ratio, and characteristic parameters (i.e. excitation temperature, electron density). An increase in ambient air pressure during ultrafast laser ablation leads to plume confinement and subsequent changes in the emission dynamics due to plasma chemistry as well as changes in plasma generation conditions (i.e. focused fs laser ablation versus filament ablation). Ablation crater morphologies were also investigated via scanning electron microscopy. Results indicate atomic emission intensity and signal-to-background ratios peak at moderate pressure levels (~50-100 Torr air) for both targets studied, although plasma chemistry influences uranium emission signatures. The emission features of the uranium plasma at pressures = 10 Torr showed the presence of atoms and oxide molecules which are co-located within the plume. We also find filament ablation leads to wider, more shallow craters compared to focused laser ablation. Our study provides unique insight into the interplay between plume dynamics, confinement, and oxygen chemistry of fs laser-produced plasmas and how these phenomena evolve with changing ambient air pressure.

Laser-produced plasma↗

Hyperfine structures and isotopic shifts of uranium transitions using tunable laser spectroscopy of laser ablation plumes

We report isotopic shifts and hyperfine structures of selected U transitions employing tunable spectroscopy viz: laser-induced fluorescence and laser absorption spectroscopy of laser ablation plumes. The laser-produced plasmas were produced during ns laser ablation on a natural U metal which contains 0.7% 235U. Our results show that isotopic shifts between 238U and 235U are entangled with hyperfine structures of 235U. The isotopic ratio obtained using laser-induced fluorescence is affected by optical saturation effect. Time-resolved laser absorption spectroscopy is carried out for evaluating the optical absorption and estimating the hyperfine constants.

(020.3260) Isotope shifts↗

Expansion dynamics and chemistry evolution in ultrafast laser filament produced plasmas

Laser ablation in conjunction with optical emission spectroscopy is a potential non-contact, standoff detection method for all elements in the periodic table and certain isotopes such as radionuclides. Currently, significant development efforts are on-going to use ultrafast laser filaments for remote sensing. The application of filaments is of particular interest in extending the range of stand-off capability associated with elemental and isotopic detection via laser-induced breakdown spectroscopy. In this study, we characterize the expansion dynamics and chemical evolution of filament-produced uranium (U) plasmas. Laser filaments are generated in the laboratory by loosely focusing 35 femtosecond (fs), 6 milli Joule (mJ) pulses in air. Two-dimensional spectrally-integrated and time-resolved imaging was performed to study hydrodynamics and evolution of U atomic and UO molecular emission in filament-produced U plasmas. Our results highlight that filament ablation of U plasmas gives a cylindrical plasma plume morphology with an appearance of plume splitting into slow and fast moving components at later times of its evolution. Emission from the slow-moving region shows no distinct spectral features (i.e. broadband-like) and is contributed in part by nanoparticles generated during ultrafast laser ablation. Additionally, we find U atoms and U oxide molecules (i.e. UO, UxOy) co-exist in the filament produced plasma, which can be attributed to the generation of low-temperature plasma conditions during filament ablation

(140.3440) Laser-induced breakdown, (280.5395) Pla↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ measurement of pyrolysis and combustion gases from biomass burning using swept wavelength external cavity quantum cascade lasers

Broadband high-speed absorption spectroscopy using swept-wavelength external cavity quantum cascade lasers (ECQCLs) is applied to measure multiple pyrolysis and combustion gases in biomass burning experiments. Two broadly-tunable swept-ECQCL systems were used, with the first tuned over a range of 2089-2262 cm -1 (4.42 – 4.79 µm) to measure spectra of CO 2 , H 2 O, and CO. The second was tuned over a range of 920-1150 cm -1 (8.70 – 10.9 µm) to measure spectra of ammonia (NH 3 ), ethene (C 2 H 4 ), and methanol (MeOH). Absorption spectra were measured continuously at a 100 Hz rate throughout the burn process, including inhomogeneous flame regions, and analyzed to determine time-resolved gas concentrations and temperature. The results provide in-situ, dynamic information regarding gas-phase species as they are generated, close to the biomass fuel source.

09 BIOMASS FUELS↗

Time-resolved imaging of atoms and molecules in laser-produced uranium plasmas

Gas-phase oxidation of uranium (U), plume chemistry, and its impact on optical emission features of the uranium plasma are investigated. Plasmas were produced via nanosecond laser ablation of a natural uranium target in a chamber where uranium oxidation was controlled by varying the oxygen partial pressure within argon cover gas. Monochromatic imaging of uranium atoms and monoxide molecules was performed using narrowband optical filters, which clearly reveals the spatio-temporal evolution of these species in the plasma. Uranium oxides are found to be formed at the plasma edges, where lower temperatures favor molecular recombination. Segregation between the distribution of uranium atoms and monoxide species is observed at later times of plasma evolution, and is more apparent at lower oxygen partial pressures. At higher oxygen partial pressures, significant variation in plume morphology is noticed for UO species, which is attributed to higher rate of oxide (UxOy) formation at the plume edges. The monochromatic images of U atoms and molecules and corresponding spectral features at various oxygen partial pressures presented here provide a unique insight into gas-phase, high-temperature uranium oxidation, and its chemistry and have implications for a wide range of nuclear applications, from stand-off detection of radioisotopes to forensics and safeguards.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Characterization of high-explosive detonations using broadband infrared external cavity quantum cascade laser absorption spectroscopy

Infrared laser absorption spectroscopy provides a powerful tool for probing physical and chemical properties of high explosive detonations. A broadly-tunable swept-wavelength external cavity quantum cascade laser (ECQCL) operating in the mid-wave infrared (MWIR) spectral region is used to measure transmission through explosive fireballs generated from 14 g charges of 4 different explosive types detonated in an enclosed chamber. Analysis of time-resolved transmission and emission at a 2 µs sampling rate shows the evolution of fireball infrared opacity in the first 10 ms after detonation. Broadband high-resolution absorption spectra acquired over the spectral range 2050-2300 cm -1 (4.35-4.88 µm) at a 100 Hz rate are used to measure properties of fireball evolution over longer time scales out to 100 s. Path-integrated concentrations of combustion products CO, CO 2 , H 2 O, and N 2 O are measured and show evolutions over multiple time scales and significant differences between explosive types. Spectral analysis is used to characterize gas temperature and to measure broadband attenuation from absorption and scattering of particulates. In conclusion, analysis of the results provides information on the MWIR optical properties, gaseous detonation/combustion products, and particulates throughout the explosive process including initial detonation, fireball expansion and cooling, and diffusive mixing in the chamber.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Plume dynamics and gas-phase molecular formation in transient laser-produced uranium plasmas

The dynamics of expansion, thermodynamics, and chemical reactions in laser-produced plasmas is of general interest for all laser ablation applications. This study investigates the complex morphology and behavior of reactive species in nanosecond laser-produced uranium plasmas. Comparing plasma morphology in various inert and reactive ambient gases provides information about the role of gas-phase chemistry in plume hydrodynamics. Background gases including nitrogen and argon foster collisional interactions leading to more significant plume confinement and the increase in persistence of uranium species. On the other hand, environments containing reactive gases such as oxygen promote chemical reactions between the plasma and ambient species. By comparing the expansion dynamics of uranium plumes in nitrogen, air, and argon, we discover that chemical reactions modify the hydrodynamics of the plume at later times of its evolution in the air background. Furthermore, we observe that varying the concentration of oxygen in the fill gas promotes different reaction pathways that lead to the formation of uranium oxides. The reaction pathways from atoms to diatomic to polyatomic molecules strongly vary with ambient oxygen concentration. Lower oxygen concentrations enhance the formation of uranium monoxide from atomic uranium, whereas higher oxygen concentrations tend to depopulate both atomic uranium and uranium monoxide concentrations through the formation of more complex uranium oxides.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical conditions for UO formation in laser-produced uranium plumes

Laser-induced plasma spectroscopy is a powerful method for elemental detection and analysis, however the broadening and merging of densely packed spectral lines can make it especially challenging for studying high-Z elements such as uranium and other actinides. In order to understand the processes occurring in laser-induced plasma, it is necessary to evaluate the variation of its thermodynamic parameters. We performed spatiotemporal diagnostics of uranium species in plasma plumes produced by nanosecond near-infrared laser pulses in low- pressure environment. Spatially- and temporally-resolved emission spectroscopy experiments are supported by modeling of uranium emission and its persistence in the plume. Saha-Eggert equation as well as Boltzmann diagrams generated from numerous U I transitions are used to infer temperature. We report the rst measurements of uranium Stark broadening parameters for U I 499.01 nm and U II 500.82 nm transitions. The Stark widths of selected U transitions were measured by comparing their linewidths with the broadening of O I 777.19 nm line. Electron density was found to be on the order of 1016 cm??3, while the temperature was found to be in the range of 3000{8000 K. In addition to enhancing the fundamental understanding of high-Z plasmas under reduced-pressure environments, the knowledge of Stark broadening parameters could improve modeling capabilities and analytical performance of techniques that rely on emission plasma spectroscopy.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

Time-resolved dual-comb measurement of number density and temperature in a laser-induced plasma

We demonstrate time-resolved dual-comb spectroscopy of a laser-induced plasma and characterize the temporal evolution of the absorption excitation temperature and population number density for multiple Fe transitions. The spectrum of three excited-state transitions of Fe around 533 nm are simultaneously detected at different time delays following laser ablation of a stainless steel sample. This work probes late-time behavior of laser-induced ablation plumes during plasma cooling, significant for revealing important information on molecule and particle formation. The high spectral resolution and broadband capability of the dual-comb technique, combined with time-resolved measurement capability, will aid in characterization of plasma properties, species identification, and higher resolution spectroscopy including isotopic analysis.

(140.3440) Laser-induced breakdown, (280.5395) Pla↗

Real-time standoff detection of nitrogen isotopes in ammonia plumes using a swept external cavity quantum cascade laser

A swept-wavelength external cavity quantum cascade laser is used to measure time-resolved 15NH3 and 14NH3 concentrations and isotope ratios in a turbulent plume source located at 10 m standoff distance. Measurements show excellent agreement with expected values of isotope ratios for samples with natural and enriched 15N abundance. Detection sensitivity of 150 ppb*m is demonstrated for a 50 ms measurement interval, improving to 10 ppb*m with 10 s averaging, with isotopic precision as good as 0.8%.

Phillips, Mark C.↗

ELUCIDATING URANIUM MONOXIDE SPECTRAL FEATURES FROM A LASER-PRODUCED PLASMA

Uranium, because of its pyrophoricity, oxidizes rapidly in an oxygen-containing high-temperature environment. However, so far, the identification of UO emission from a laser-produced plasma system is limited to a spectral feature around 593.55 nm. The aim of this study is to elucidate UO emission features in the visible spectral regime from uranium plasmas generated in an oxygen-containing ambient environment. The plasmas are produced by focusing nanosecond laser pulses on a uranium metal target in a controlled ambient environment. Space- and time-resolved optical emission spectroscopic investigations are used for isolating U molecular emission structures from crowded U atomic line emission. Our studies highlight that the emission from a U plasma even in the presence of trace oxygen is accompanied by a strong background-like emission with partially resolved bands from uranium monoxide and higher oxides. We also report several UO spectral emission bands in the visible spectral region.

(300.2140) Emission Spectroscopy, (280.5395) Plasm↗