This report requests a non-explosive hazard classification of trace explosives in solution. UN Series 1 and 2 explosive hazard classification tests were performed on a simulated worst-case waste stream of five (5) percent by weight of explosive (CL-20) dissolved in a solvent solution (acetone) for transport and storage. The explosive hazard classification test results reported the sample to be non-explosive and the report provides the necessary data for the Department of Transportation to determine and assign the appropriate hazard class for five (5) percent or less of trace explosive in solvent solutions when being shipped and/or stored. Based on the test results, this report requests that the Department of Transportation assign a hazard class of 3, Desensitized explosive liquid, n.o.s. for this type of substance.
Impact sensitivity testing was performed using a modified Bureau of Mines (MBOM) impactor manufactured by Safety Management Services, Inc. Type-12 tooling was utilized on this machine with a 2.5kg impactor and matching intermediate mass. This particular machine is capable of a maximum drop height of 115cm with 0.1 cm increments, though 1 cm increments are typically used. Sample material was placed (35 ± 2mg) onto 1 inch squares of Norton brand 180A Garnet sandpaper. Positive results were detected visually or audibly by the operator as smoke, flash, report, charring/tearing of the sandpaper, etc. The test was conducted using the Bruceton technique to calculate the height at which there is a 50% chance of initiation (H 50 ).
Impact sensitivity testing was performed using a modified Bureau of Mines (MBOM) impactor manufactured by Safety Management Services, Inc., shown in Figure 1. Type-12 tooling was utilized on this machine with a 2.5kg impactor and matching intermediate mass. This particular machine is capable of a maximum drop height of 115cm with 0.1cm increments, though 1cm increments are typically used. Sample material was placed (35 ± 2mg) onto 1 inch squares of Norton brand 180A Garnet sandpaper. Positive results were detected visually or audibly by the operator as smoke, flash, report, charring/tearing of the sandpaper, etc.
Abstract not provided.
Based upon the presented sensitivity data for the examined calcium nitrate mixtures using sugar and sawdust, contact handling/mixing of these materials does not present hazards greater than those occurring during handling of dry PETN powder. The aluminized calcium nitrate mixtures present a known ESD fire hazard due to the fine aluminum powder fuel. These mixtures may yet present an ESD explosion hazard, though this has not been investigated at this time. The detonability of these mixtures will be investigated during Phase III testing.