Effects of truncation of a predominantly compression load spectrum on the life of a notched graphite/epoxy laminate
Constant amplitude and transport wing spectrum compressive loading tests were used to explore the fatigue behavior of a notched, graphite/epoxy T300/5208 laminate specimen. Results indicate that (1) the amount of buckling near the notch allowed in the tests significantly affected fatigue life; (2) load spectrum truncation at either high or low ends produced lives greater than those obtained for the baseline complete-spectrum test, but with greater impact at the high-load end; and (3) the predictions of the Palmgren-Miner cumulative damage theory were found to always be far longer than those obtained in the spectrum loading tests.