Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selective modulation of electronic transport in VO 2 induced by 10 keV helium ion irradiation

Vanadium dioxide (VO 2 ) manifests an abrupt metal–insulator transition (MIT) from monoclinic to rutile phases, with potential use for tunable electronic and optical properties and spiking neuromorphic devices. Understanding pathways to modulate electronic transport in VO 2 , as well as its response to irradiation (e.g., for space applications), is critical to better enable these applications. In this work, we investigate the selective modulation of electronic transport in VO 2 films subject to different 10 keV helium ion (He + ) fluences. Under these conditions, the resistivity in the individual monoclinic and rutile phases varied by 50%–200%, while the MIT transformation temperature remains constant within 4 °C independent of irradiation fluence. Importantly, different trends in the resistivity of the monoclinic and rutile phases were observed both as a function of total He fluence as well as in films grown on different substrates (amorphous SiO 2 /Si vs single crystal Al 2 O 3 ). Through a combination of measurements including majority carrier sign via Seebeck, low frequency noise, and TEM, our investigation supports the presence of different kinds of point defects (V in; O in), which may arise due to grain boundary defect interactions. Our work suggests the utility of He irradiation for the selective modulation of VO 2 transport properties for neuromorphic, in contrast to other established but non-selective methods, like doping.

36 MATERIALS SCIENCE↗

ABC -Auxetics: An Implicit Design Approach for Negative Poisson's Ratio Materials

A novel methodology is introduced for designing auxetic (negative Poisson's ratio) structures based on topological principles and is demonstrated by investigating a new class of auxetics based on two-dimensional (2D) textile weave patterns. Conventional methodology for designing auxetic materials typically involves determining a single deformable block (a unit cell) of material whose shape results in auxetic behavior. Consequently, patterning such a unit cell in a 2D (or 3D) domain results in a larger structure that exhibits overall auxetic behavior. Such an approach naturally relies on some prior intuition and experience regarding which unit cells may be auxetic. Second, tuning the properties of the resulting structures is typically limited to parametric variations of the geometry of a specific type of unit cell. Thus, most of the currently known auxetic structures belong to a selected few classes of unit cell geometries that are explicitly defined in accordance with a specified topological (i.e., grid structure). Herein, a new class of auxetic structures is demonstrated that, while periodic, can be generated implicitly, i.e., without reference to a specific unit cell design. The approach leverages weave-based parameters (A–B–C), resulting in a rich design space for auxetics that is previously unexplored.

36 MATERIALS SCIENCE↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

Compatibility of ethylene vinyl acetate (EVA)/ethylene vinyl alcohol (EVOH)/EVA films with gamma, electron-beam, and X-ray irradiation

Many polymer-based medical devices are sterilized by gamma irradiation. To reduce the use of cobalt-60 gamma-ray sources, transition from gamma ray to alternative irradiation technologies was proposed, namely electron beam (e-beam) and X-ray. A major impediment for such a transition is the knowledge gap in material compatibility with the different radiation sources. In this study, multi-layer films consisting of ethylene vinyl acetate (EVA) and ethylene vinyl alcohol (EVOH) components were irradiated to target doses of 30, 45, and 60 kGy by gamma-ray, e-beam, and X-ray sources. Effects of irradiation were evaluated on 12 material properties, and statistical comparisons between gamma irradiation and alternative technologies were conducted using the two one-sided t-test (or “equivalence test”) and classic t-test. Melting temperature and UV absorbance below 300 nm showed dose dependencies, while other investigated properties such as discoloration and mechanical durability did not change with dose up to 60 kGy. Based on these results, there is no material compatibility issue associated with the transition from gamma to e-beam or to X-ray as source of sterilization radiation of the studied multi-layer film.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanistic origins of corrosion protection of aluminum alloys by graphene/polyetherimide nanocomposite coatings

Light-weighting vehicular components through adoption of light-metal structural alloys holds promise for reducing the fuel consumption of internal combustion engine vehicles and increasing the range of battery electric vehicles. However, the alloyed microstructure and surface precipitates of aluminum alloys render these materials susceptible to corrosion under modest excursions from neutral pH. Traditional chromium-based anodic passivation layers are subject to increasingly stringent environmental regulations, whereas options for sacrificial cathodic films are sparse for electropositive metals. While hybrid nanocomposite coatings have shown initial promise, mechanistic underpinnings remain poorly understood. Here, a fully imidized polyetherimide (PEI) resin is utilized as the continuous phase with inclusion of unfunctionalized exfoliated graphite (UFG). A comprehensive investigation of the mechanisms of corrosion protection reveals key fundamental design principles underpinning corrosion inhibition. First, strong interfacial adhesion, which for PEI is facilitated by binding of imide carbonyl moieties to Lewis acidic sites on Al surfaces. Second, the miscibility of ion-impervious nanoscopic UFG fillers and stabilization of a substantial interphase region at UFG/PEI boundaries that result in minimizing the free volume at the filler/polymer interface. Finally, extended tortuosity of ion diffusion pathways imbued by the below-percolation-threshold 2D fillers. These three design principles help govern and modulate ion transport from electrolyte/coating interfaces to the coating/metal interface and are crucial for the extended preservation of barrier properties. The results suggest an approach to systematically activate multiple modes of corrosion inhibition through rational design of hybrid nanocomposite coatings across hard-to-abate sectors where light metal alloys are likely to play an increasingly prominent role.

36 MATERIALS SCIENCE↗

A reference-area-free strain mapping method using precession electron diffraction data

Here, in this work, we developed a method using precession electron diffraction data to map the residual elastic strain at the nano-scale. The diffraction pattern of each pixel was first collected and denoised. Template matching was then applied using the center spot as the mask to identify the positions of the diffraction disks. Statistics of distances between the selected diffracted disks enable the user to make an informed decision on the reference and to generate strain maps. Strain mapping on an unstrained single crystal sapphire shows the standard deviation of strain measurement is 0.5%. With this method, we were able to successfully measure and map the residual elastic strain in VO 2 on sapphire and martensite in a Ni 50.3 Ti 29.7 Hf 20 shape memory alloy. This approach does not require the user to select a “strain-free area” as a reference and can work on datasets even with the crystals oriented away from zone axes. This method is expected to provide a robust and more accessible alternative means of studying the residual strain of various material systems that complements the existing algorithms for strain mapping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystallographic variant mapping using precession electron diffraction data

In this work, we developed three methods to map crystallographic variants of samples at the nanoscale by analyzing precession electron diffraction data using a high-temperature shape memory alloy and a VO2 thin film on sapphire as the model systems. The three methods are (I) a user-selecting-reference pattern approach, (II) an algorithm-selecting-reference-pattern approach, and (III) a k-means approach. In the first two approaches, Euclidean distance, Cosine, and Structural Similarity (SSIM) algorithms were assessed for the diffraction pattern similarity quantification. We demonstrated that the Euclidean distance and SSIM methods outperform the Cosine algorithm. We further revealed that the random noise in the diffraction data can dramatically affect similarity quantification. Denoising processes could improve the crystallographic mapping quality. With the three methods mentioned above, we were able to map the crystallographic variants in different materials systems, thus enabling fast variant number quantification and clear variant distribution visualization. The advantages and disadvantages of each approach are also discussed. We expect these methods to benefit researchers who work on martensitic materials, in which the variant information is critical to understand their properties and functionalities.

Crystallographic variant mapping↗

Cation reordering instead of phase transitions: Origins and implications of contrasting lithiation mechanisms in 1D ζ- and 2D α-V 2 O 5

Substantial improvements in cycle life, rate performance, accessible voltage, and reversible capacity are required to realize the promise of Li-ion batteries in full measure. Here, we have examined insertion electrodes of the same composition (V 2 O 5 ) prepared according to the same electrode specifications and comprising particles with similar dimensions and geometries that differ only in terms of their atomic connectivity and crystal structure, specifically two-dimensional (2D) layered α-V 2 O 5 that crystallizes in an orthorhombic space group and one-dimensional (1D) tunnel-structured ζ-V 2 O 5 crystallized in a monoclinic space group. By using particles of similar dimensions, we have disentangled the role of specific structural motifs and atomistic diffusion pathways in affecting electrochemical performance by mapping the dynamical evolution of lithiation-induced structural modifications using ex situ scanning transmission X-ray microscopy, operando synchrotron X-ray diffraction measurements, and phase-field modeling. We find the operation of sharply divergent mechanisms to accommodate increasing concentrations of Li-ions: a series of distortive phase transformations that result in puckering and expansion of interlayer spacing in layered α-V 2 O 5 , as compared with cation reordering along interstitial sites in tunnel-structured ζ-V 2 O 5 . By alleviating distortive phase transformations, the ζ-V 2 O 5 cathode shows reduced voltage hysteresis, increased Li-ion diffusivity, alleviation of stress gradients, and improved capacity retention. The findings demonstrate that alternative lithiation mechanisms can be accessed in metastable compounds by dint of their reconfigured atomic connectivity and can unlock substantially improved electrochemical performance not accessible in the thermodynamically stable phase.

25 ENERGY STORAGE↗

Effects of X-Rays, Electron Beam, and Gamma Irradiation on Chemical and Physical Properties of EVA Multilayer Films

Gamma-ray irradiation, using the cobalt-60 isotope, is the most common radiation modality used for medical device and biopharmaceutical products sterilization. Although X-ray and electron-beam (e-beam) sterilization technologies are mature and have been in use for decades, impediments remain to switching to these sterilization modalities because of lack of data on the resulting radiation effects for the associated polymers, as well as a lack of education for manufacturers and regulators on the viability of these sterilization alternatives. For this study, the compatibility of ethylene vinyl acetate (EVA) multilayer films with different ionizing radiation sterilization (X-ray, e-beam, and gamma irradiation) is determined by measuring chemical and physical film properties using high performance liquid chromatography, differential scanning calorimetry, Fourier-Transform InfraRed spectroscopy (FTIR), surface energy measurement, and electron spin resonance techniques. The results indicate that the three irradiation modalities induce no differences in thermal properties in the investigated dose range. Gamma and X-Ray irradiations generate the same level of reactive species in the EVA multilayer film, whereas e-beam generates a reduced quantity of reactive species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Supplementing Gamma Sterilization with X-Ray and E-Beam Technologies: An International Industry and Academia Collaboration

Ionizing-technology–based industries are growing rapidly around the world. The expansion is driven mostly by the technology’s myriad applications, including polymer crosslinking, medical device sterilization, food pasteurization, and phytosanitary treatment. Ionization also is used in the manufacture of some healthcare products such as medical devices and biopharmaceuticals. Industrial sterilization methods render single-use products and manufacturing components safe and ready for their intended use. ISO11137-1 describes the validation and routine control of a sterilization process for medical devices and mentions the three types of radiation considered under this scope: gamma, X-ray, and electron beam (e-beam)

gamma sterilization, electron beam sterilization, ↗

Effect of crystallite geometries on electrochemical performance of porous intercalation electrodes by multiscale operando investigation

Lithium-ion batteries are yet to realize their full promise because of challenges in the design and construction of electrode architectures that allow for their entire interior volumes to be reversibly accessible for ion storage. Electrodes constructed from the same material and with the same specifications, which differ only in terms of dimensions and geometries of the constituent particles, can show surprising differences in polarization, stress accumulation and capacity fade. Here, using operando synchrotron X-ray diffraction and energy dispersive X-ray diffraction (EDXRD), we probe the mechanistic origins of the remarkable particle geometry-dependent modification of lithiation-induced phase transformations in V2O5 as a model phase-transforming cathode. A pronounced modulation of phase coexistence regimes is observed as a function of particle geometry. Specifically, a metastable phase is stabilized for nanometre-sized spherical V2O5 particles, to circumvent the formation of large misfit strains. Spatially resolved EDXRD measurements demonstrate that particle geometries strongly modify the tortuosity of the porous cathode architecture. Greater ion-transport limitations in electrode architectures comprising micrometre-sized platelets result in considerable lithiation heterogeneities across the thickness of the electrode. These insights establish particle geometry-dependent modification of metastable phase regimes and electrode tortuosity as key design principles for realizing the promise of intercalation cathodes. Designing electrode architectures for Li-ion batteries that can be reversibly accessible for ion storage can be challenging. Using operando techniques the mechanistic origin of lithiation-induced phase transformations in a V2O5 model cathode is now clarified.

Luo, Yuting↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Semi-solid alkali metal electrodes enabling high critical current densities in solid electrolyte batteries

The need for higher energy density rechargeable batteries has generated interest in alkali metal electrodes paired with solid electrolytes. However, metal penetration and electrolyte fracture at low current densities have emerged as fundamental barriers. Here, we show that for pure metals in the Li-Na-K system, the critical current densities scale inversely to mechanical deformation resistance. Furthermore, we demonstrate two electrode architectures in which the presence of a liquid phase enables high current densities while preserving the shape retention and packaging advantages of solid electrodes. First, biphasic Na-K alloys show K + critical current densities (with K-β*-Al 2 O 3 electrolyte) that exceed 15 mA∙cm -2 . Second, introducing a wetting interfacial film of Na-K liquid between Li metal and Li 6.75 La 3 Zr 1.75 Ta 0.25 O 12 (LLZTO) solid electrolyte doubles the critical current density and permits cycling at areal capacities exceeding 3.5 mAh∙cm -2 . These design approaches hold promise for overcoming electro-chemo-mechanical stability issues that have heretofore limited performance of solid-state metal batteries.

25 ENERGY STORAGE↗

Transitioning from Cobalt-60 to X-Ray or E-Beam for Medical Sterilization: Filling Data and Education Gaps

The Office of Radiological Security (ORS) within the U.S. DOE’s National Nuclear Security Administration (NNSA) is charged to “work with government, law enforcement, and businesses across the globe to protect radioactive sources used for medical, research, and commercial purposes; remove and dispose of disused radioactive sources; and reduce the global reliance on high activity radioactive sources through the promotion of viable non-radioisotopic alternative technologies.” In this effort, the NNSA/ORS, along with the Office of Defense Nuclear Nonproliferation R&D, has been working with government and private entities that utilize gamma-ray irradiators in areas that include blood irradiation, radiotherapy, biology research, well logging, and radiation processing to consider alternative technologies that do not depend upon radioactive materials. In the medical device industry, nearly 50% of products are sterilized with ethylene oxide, 40.5% with cobalt-60 gamma-rays, 4.5% with electron-beam (e-beam), and <1% with X-ray.(1,2) The cobalt-60 irradiation facilities use an estimated 150 MCi of isotope to sterilize approximately 200 million cubic feet of product annually.(3) Due to growing safety regulations governing cobalt-60 use, continued advancements in e-beam and X-ray accelerator technology, and the greater irradiation durations and costs for cobalt-60 irradiation compared to e-beam and X-ray, switching to these non-radionuclide modalities is increasingly economically competitive. However, this breakdown of 40.5% cobalt-60 and 5.5% accelerator for product sterilization illustrates the difficulty that market forces and industry players have had in overcoming barriers in transitioning to non-nuclide alternatives. Besides those associated with construction of new e-beam and X-ray facilities, significant financial and regulatory obstacles are also associated with the irradiation and comprehensive testing of product constituent polymers and elastomers. The standards associated with product material performance testing are the Association for the Advancement of Medical Instrumentation (AAMI) Technical Information Report 17 (TIR 17), and its referenced American Society for Testing and Materials (ASTM) polymer testing standards. In the study now underway, and the subject of this article, the NNSA/ORS provided R&D funding to the Pacific Northwest National Laboratory (PNNL) in partnership with university researchers, leading medical product manufacturers, accelerator manufacturers, and contract sterilizers. The resulting Team Nablo (in memory of Sam Nablo) includes individuals representing PNNL, Becton Dickinson (BD), Johnson & Johnson, Stryker, Texas A&M University (TAMU), Steri-Tek, Mevex, Ion Beam Applications (IBA), and Sterigenics. The goals of this study are to 1) Identify specific polymer and/or elastomer-based medical products that are currently sterilized with gamma-rays, and for which there are data gaps and would be of greatest industry impact, 2) Work with relevant ASTM subcommittees for guidance and for potential standard revision, 3) Work with an appropriate Food & Drug Administration (FDA) office for potential collaboration on a guidance document for device manufacturers, 4) Measure the physical effects that product materials exhibit when they are given sterilization-level radiation doses from cobalt-60, e-beam or X-ray, and determine whether these effects would preclude the use of e-beam or X-ray for sterilization, 5) Communicate the resulting scientific datasets and findings via industry conferences, peer-reviewed journals, and relevant trade magazines, and 6) Post the resulting datasets on a publicly accessible website, which can be built on in future years. The end objective is to identify technical barriers preventing the adoption of X-ray and e-beam technologies, and share the results to encourage X-ray and e-beam adoption where feasible.

sterilization, alternate technologies, gamma, X-ra↗