Engineering PapersSearch

Engineering topics

Petrone, P.

Publications and source records attributed to Petrone, P..

Vacuum Nuller Testbed Performance, Characterization and Null Control

The Visible Nulling Coronagraph (VNC) can detect and characterize exoplanets with filled, segmented and sparse aperture telescopes, thereby spanning the choice of future internal coronagraph exoplanet missions. NASA/Goddard Space Flight Center (GSFC) has developed a Vacuum Nuller Testbed (VNT) to advance this approach, and assess and advance technologies needed to realize a VNC as a flight instrument. The VNT is an ultra-stable testbed operating at 15 Hz in vacuum. It consists of a MachZehnder nulling interferometer; modified with a "W" configuration to accommodate a hexpacked MEMS based deformable mirror (DM), coherent fiber bundle and achromatic phase shifters. The 2-output channels are imaged with a vacuum photon counting camera and conventional camera. Error-sensing and feedback to DM and delay line with control algorithms are implemented in a real-time architecture. The inherent advantage of the VNC is that it is its own interferometer and directly controls its errors by exploiting images from bright and dark channels simultaneously. Conservation of energy requires the sum total of the photon counts be conserved independent of the VNC state. Thus sensing and control bandwidth is limited by the target stars throughput, with the net effect that the higher bandwidth offloads stressing stability tolerances within the telescope. We report our recent progress with the VNT towards achieving an incremental sequence of contrast milestones of 10(exp 8) , 10(exp 9) and 10(exp 10) respectively at inner working angles approaching 2A/D. Discussed will be the optics, lab results, technologies, and null control. Shown will be evidence that the milestones have been achieved.

Lyon, R. G.

Segmented mirror coarse phasing with a dispersed fringe sensor: experiments on NGST's wavefront control testbed

A piston sensing and control algorithm for the segmented mirror coarse phasing using a dispersed fringe sensor (DFS) has been developed for Next Generation Space Telescope (NGST) wavefront sensing and control. The DFS can detect residual piston errors as large as order of a depth-of-focus and can phase the segment mirrors with an accuracy less than 0.1 micron, which is within the capture range of the fine phasing for NGST. A series of experiments has been carried out on the NGST's Wavefront Control Testbed (WCT) to validate the modeling results, evaluate the DFS performance, and systematically explore the factors that affect the DFS performance. This paper reports the testbed results for several critical issues of DFS performance, including DFS dynamic range, accuracy, fringe visibility, and the effects of segment mirror aberrations.

Space

Segmented mirror coarse phasing with white light interferometry: modeling and experiment on NGST's wavefront control testbed

A method of coarse phasing segmented mirrors using white light interferometry (WLI) has been developed for Next Generation Space Telescope (NGST) wavefront sensing and control. Using the broadband point spread function (PSF) of the segmented mirrors taken during a segment piston scan, the WLI can accurately detect small residual piston errors. WLI does not rely on any extra optics and uses only the final imaging camera. With its high sensitivity to small segment piston error WLI can be used as a complementary phasing algorithm to the dispersed fringe sensor (DFS) for NGST. The paper will present the results from modeling and experiment on the NGST's Wavefront Control Testbed (WCT).

Space

NGST wavefront control

Explore the source record for details and available documents.

wavefront control space telescopes NGST

Polarization of microwave noise source radiation in the 30 GHz to 300 GHz range

Radiation spectra have been obtained in order to calculate the frequency bandwidth and polarization of three microwave noise sources. Results were obtained in the 1-10-mm wavelength region using a lamellar grating Fourier transform spectrometer and a helium-cooled bolometer detector. A secondary transmission region was found to have an input current as well as a polarization dependence, despite the directional output of the waveguide antenna.

Poutous, M. K.