All The Catalytic Active Sites of MoS 2 for Hydrogen Evolution
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Peterson, David.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Ionization cooling of intense muon beams requires the operation of high-gradient, normal-conducting RF structures within multi-Tesla magnetic fields. The application of strong magnetic fields has been shown to lead to an increase in vacuum RF breakdown. This phenomenon imposes operational (i.e. gradient) limitations on cavities in ionization cooling channels, and has a bearing on the design and operation of other RF structures as well, such as photocathodes and klystrons. We present recent results from Fermilab's MuCool Test Area (MTA), in which 201 and 805 MHz cavities were operated at high power both with and without the presence of multi-Tesla magnetic fields. We present an analysis of damage due to breakdown in these cavities, as well as measurements related to dark current and their relation to a conceptual model describing breakdown phenomena.
Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. Alumina of purities ranging from 96 to 99.8% was tested in a high pressure RF test cell at the MuCool Test Area at Fermilab. The results of breakdown studies with pure nitrogen gas, and oxygen-doped nitrogen gas indicate the peak surface electric field on the alumina ranges between 10 and 15 MV/m. How these results affect the design of a prototype cooling channel cavity will be discussed.
Bright muon sources require six dimensional cooling to achieve acceptable luminosities. Ionization cooling is the only known method able to do so within the muon lifetime. One proposed cooling channel, the Helical Cooling Channel, utilizes gas filled radio frequency cavities to both mitigate RF breakdown in the presence of strong, external magnetic fields, and provide the cooling medium. Engineering constraints on the diameter of the magnets within which these cavities operate dictate the radius of the cavities be decreased at their nominal operating frequency. To accomplish this, one may load the cavities with a larger dielectric material. A 99.5% alumina ring was inserted in a high pressure RF test cell and subjected to an intense proton beam at the MuCool Test Area at Fermilab. The results of the performance of this dielectric loaded high pressure RF cavity will be presented.
We report operational experience from the prototype RF module for the Muon Ionization Cooling Experiment (MICE) with final production couplers at Fermilab's MuCool Test Area. This is the last step in fully qualifying the RF modules for operation in the experiment at RAL.
Abstract not provided.
Characterising radiation from wildland fires is an important focus of fire science because radiation relates directly to the combustion process and can be measured across a wide range of spatial extents and resolutions. As part of a more comprehensive set of measurements collected during the 2012 Prescribed Fire Combustion and Atmospheric Dynamics Research (RxCADRE) field campaign, we used ground, airborne and spaceborne sensors to measure fire radiative power (FRP) from whole fires, applying different methods to small (2 ha) and large (.100 ha) burn blocks. For small blocks (n1/46), FRP estimated from an obliquely oriented long-wave infrared (LWIR) camera mounted on a boom lift were compared with FRP derived from combined data from tower-mounted radiometers and remotely piloted aircraft systems (RPAS). For large burn blocks (n1/43), satellite FRP measurements from the Moderate-resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) sensors were compared with near-coincident FRP measurements derived from a LWIR imaging system aboard a piloted aircraft. We describe measurements and consider their strengths and weaknesses. Until quantitative sensors exist for small RPAS, their use in fire research will remain limited. For oblique, airborne and satellite sensors, further FRP measurement development is needed along with greater replication of coincident measurements, which we show to be feasible.
Abstract not provided.
The exploration of large parameter spaces in search of problem solution and uncertainty quantifcation produces very large ensembles of data. Processing ensemble data will continue to require more resources as simulation complexity and HPC platform throughput increase. More tools are needed to help provide rapid insight into these data sets to decrease manual processing time by the analyst and to increase knowledge the data can provide. One such tool is Tecplot Chorus, whose strengths are visualizing ensemble metadata and linked images. This report contains the analysis and conclusions from evaluating Tecplot Chorus with an example problem that is relevant to Sandia National Laboratories. This report documents a preliminary evaluation of Tecplot Chorus for analyzing ensemble data from CTH simulations. The project that funded this report and evaluation is also evaluating and guiding development with SNL’s Slycat. Slycat and Tecplot Chorus each have their strengths, weaknesses, and overlapping capabilities. It is quite likely that, as the scale of ensemble data increases, both of these tools (and possibly others) will be needed for different processing goals. This report will focus on Tecplot Chorus and its application to an example ensemble of data supplied by David J. Peterson and John P. Korbin; this example is of a flyer plate impact and weld study henceforth referred to as CTH Impact Example. This evaluation also defines a workflow for analysts that can help reduce the time and resources for processing ensemble data.
Purpose: To evaluate factors associated with adverse cosmesis outcome in breast cancer patients randomized to accelerated partial breast irradiation (APBI) using 3-dimensional conformal radiation therapy or whole-breast irradiation in the RAPID (Randomized Trial of Accelerated Partial Breast Irradiation) trial. Methods and Materials: Subjects were trial participants with nurse-assessed global cosmetic scores at baseline and at 3 years. Adverse cosmesis was defined as a score of fair or poor. Cosmetic deterioration was defined as any adverse change in score from baseline to 3 years. The analysis is based on data from the previously reported interim analysis. Logistic regression models were used to assess the association of risk factors for these outcomes among all patients and those treated with APBI only. Results: Clinicopathologic characteristics were similar between subjects randomized to APBI (n=569) or whole-breast irradiation (n=539). For all subjects, factors associated with adverse cosmesis at 3 years were older age, central/inner tumor location, breast infection, smoking, seroma volume, breast volume, and use of APBI; factors associated with cosmetic deterioration were smoking, seroma volume, and use of APBI (P<.05). For APBI subjects, tumor location, smoking, age, and seroma volume were associated with adverse cosmesis (P<.05), and smoking was associated with cosmetic deterioration (P=.02). An independent association between the V95/whole-breast volume ratio and adverse cosmesis (P=.28) or cosmetic deterioration (P=.07) was not detected. On further exploration a V95/whole-breast volume ratio <0.15 was associated with a lower risk of cosmetic deterioration (p=.04), but this accounted for only 11% of patients. Conclusion: In the RAPID trial, a number of patient tumor and treatment-related factors, including the use of APBI, were associated with adverse cosmesis and cosmetic deterioration. For patients treated with APBI alone, the high-dose treatment volume was not independently associated with an adverse cosmetic outcome, and a useful clinical threshold could not be identified.
Not Available
Abstract Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon p-i-n diode used in the KATRIN neutrinomass experiment has such a dead layer. We have constructed a detailed Monte Carlo model for the passage of electrons from vacuum into a silicon detector, and compared the measured energy spectra to the predicted ones for a range of energies from 12 to 20 keV. The comparison provides experimental evidence that a substantial fraction of the ionization produced in the "dead" layer evidently escapes by discussion, with 46% being collected in the depletion zone and the balance being neutralized at the contact or by bulk recombination. The most elementary model of a thinner dead layer from which no charge is collected is strongly disfavored.
Pursuant to the Clean Air Act, the U.S. Environmental Protection Agency (EPA) announced in 2009 its intent to issue rules for controlling emissions from Navajo Generating Station that could affect visibility at the Grand Canyon and at several other national parks and wilderness areas. The final rule will conform to what EPA determines is the best available retrofit technology (BART) for the control of haze-causing air pollutants, especially nitrogen oxides. While EPA is ultimately responsible for setting Navajo Generating Station's BART standards in its final rule, it will be the U.S. Department of the Interior's responsibility to manage compliance and the related impacts. This study aims to assist both Interior and EPA by providing an objective assessment of issues relating to the power sector.
The Majorana Collaboration is building the Majorana Demonstrator, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The Majorana Demonstrator will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c² mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the Majorana Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.