Engineering PapersSearch

Engineering topics

Peters, P. N.

Publications and source records attributed to Peters, P. N..

27 records · Page 2

Results of apparent atomic oxygen reactions on Ag, C, and Os exposed during the Shuttle STS-4 orbits

Films selected for anticipated reaction with atomic oxygen, namely carbon, silver, and osmium, were exposed during the Shuttle STS-4 mission. A silver film within 5 nm of 225 nm thick was converted to a transparent blue-green interference film within 5 nm of 355 nm thick. Both carbon and osmium films 10-30 nm thick apparently formed volatile oxides and disappeared, except where well shielded. A calculated total of approximately 7 x 10 to the 19th oxygen atoms per sq cm struck the surfaces, which could have removed on the order of 3 microns of material if only 10 percent reacted. The absence of apparent effects on adjacent thin and thick gold films is offered as evidence that sputtering is not responsible.

Peters, P. N.

Induced Environment Contamination Monitor (IECM), air sampler - Results from the Space Transport System (STS-2) flight

An investigation involving sampling the rapidly changing environment of the Shuttle cargo bay is considered. Four time-integrated samples and one rapid acquisition sample were collected to determine the types and quantities of contaminants present during ascent and descent of the Shuttle. The sampling times for the various bottles were controlled by valves operated by the Data Acquisition and Control System (DACS) of the IECM. Many of the observed species were found to be common solvents used in cleaning surfaces. When the actual volume sampled is taken into account, the relative mass of organics sampled during descent is about 20 percent less than during ascent.

Peters, P. N.

Germanium coated microbridge and method

A superconducting microbridge is provided for use in superconducting quantum interference devices wherein a pair of spaced layers of superconductive material are connected by a weak link bridge to establish an electrical junction. The superconductive layers and bridge are coated with a semiconductor material shunting the bridge at room temperatures to prevent the destruction of the device by minute electrical currents while the coating acts as a dielectric permitting normal electrical behavior of the microbridge at cryogenic temperatures.

Holderman, L. B.

Germanium-overcoated niobium Dayem bridges

Overcoating constriction microbridges with semiconducting germanium provides additional thermal conductivity at liquid-helium temperatures to reduce the effects of self-heating in these Josephson junctions. Microwave-induced steps were observed in the I-V characteristics of an overcoated Dayem bridge fabricated in a 15-nm-thick niobium film; at least 20 steps could be counted at 4.2 K. No steps were observed in the I-V characteristics of the bridge prior to overcoating. In addition, the germanium overcoat can protect against electrical disturbances at room temperature.

Holdeman, L. B.

Ellipsometer for measurement in ultrahigh vacuum

Ellipsometer, used with ultrahigh vacuum, allows measurement of varied angles of incidence. Vacuum chamber, directly incorporated into optical bench systems, allows varied angle measurements to be taken through same region of a window.

Walter, H. U.

Superconducting quantum-interference devices

Published document discusses devices which are based on weak-link Josephson elements that join superconductors. Links can take numerous forms, and circuitry utilizing links can perform many varied functions with unprecedented sensitivity. Theoretical review of Josephson's junctions include tunneling junctions, point contact devices, microbridges, and proximity-effect devices.

Peters, P. N.

An ellipsometer with variable angle of incidence for studies in ultrahigh vacuum

The windows for the vacuum chamber are incorporated into the optical bench system by means of flexible bellows which allow measurements to be made over a large range of angle of incidence, one of which is chosen so that maximum sensitivity is obtained. The principal angle of incidence was determined, and straightforward corrections for strain birefringence of vacuum chamber windows were made. Atomically clean surfaces of sodium chloride and lithium fluoride were investigated to verify the performance of the system. Submonolayer and monolayer coverage of water on these surfaces could be detected. On cleavage planes of NaCl, a first monolayer of adsorbed water is complete at about one torr only.

Walter, H. U.

Auger measurements on T-027 samples exposed during the Skylab 2 mission

Auger electron spectroscopy measurements performed on Skylab 2 indicate a low rate of deposition of permanent, continuous film contamination on nickel and gold surfaces positioned on the antisolar side of the spacecraft. These measurements and supportive evidence indicate that for the particular locations and orientations of these samples permanent films of less than 3 nm (30 A) thickness were deposited during an exposure of 40 hours at a temperature of approximately -32 C.

Peters, P. N.