Engineering PapersSearch

Engineering topics

Peters, H. E.

Publications and source records attributed to Peters, H. E..

Atomic hydrogen maser active oscillator cavity and bulb design optimization

The performance characteristics and reliability of the active oscillator atomic hydrogen maser depend upon oscillation parameters which characterize the interaction region of the maser, the resonant cavity and atom storage bulb assembly. With particular attention to use of the cavity frequency switching servo (1) to reduce cavity pulling, it is important to maintain high oscillation level, high atomic beam flux utilization efficiency, small spin exchange parameter and high cavity quality factor. It is also desirable to have a small and rigid cavity and bulb structure and to minimize the cavity temperature sensitivity. Curves for a novel hydrogen maser cavity configuration which is partially loaded with a quartz dielectric cylinder and show the relationships between cavity length, cavity diameter, bulb size, dielectric thickness, cavity quality factor, filling factor and cavity frequency temperature coefficient are presented. The results are discussed in terms of improvement in maser performance resulting from particular design choices.

Peters, H. E.

Magnetic state selection in atomic frequency and time standards

Atomic standards such as those based upon cesium and hydrogen rely upon magnetic state selection to obtain population inversion in the hyperfine transition levels. Use of new design approaches and improved magnetic materials has made it possible to fabricate improved state selectors of small size, and thus the efficiency of utilization of beam flux is greatly improved and the size and weight of the standard is reduced. The sensitivity to magnetic perturbations is also decreased, so that the accuracy and stability of the standard is improved. Several new state selector designs are illustrated and the application to standards utilizing different atomic species is analyzed.

Peters, H. E.

An improved method for measuring the magnetic inhomogeneity shift in hydrogen masers

The reported method makes it possible to conduct all maser frequency measurements under conditions of low magnetic field intensity for which the hydrogen maser is most stable. Aspects concerning the origin of the magnetic inhomogeneity shift are examined and the available approaches for measuring this shift are considered, taking into account certain drawbacks of currently used methods. An approach free of these drawbacks can be based on the measurement of changes in a parameter representing the difference between the number of atoms in the involved states.

Reinhardt, V. S.

The concertina hydrogen maser

A description is presented of a promising approach for measuring the wall shift in a hydrogen maser with a net uncertainty of one or two parts in 100 trillion. The hydrogen maser principles are briefly examined and the wall shift is discussed, taking into account the interaction of the atom with the wall, the wall shift relationship, and previous wall shift measurement techniques. The essential principles of a 'concertina' variable volume bulb maser are considered along with variable volume maser wall shift errors, design details, and the fabrication of the storage bulb.

Peters, H. E.

Atomic frequency standard relativistic Doppler shift experiment

An experiment has been performed to measure possible space anisotropy as it would effect the frequency of a cesium atomic beam standard clock in a laboratory on earth due to motion relative to external coordinate frames. The cesium frequency was measured as a function of orientation with respect to an atomic hydrogen maser standard. Over a period of 34 days 101 measurements were made. The results are consistent with a conclusion that no general orientation dependance attributable to spacial anisotropy was observed. It is shown that both the airplane clock results, and the null results for the atomic beam clock, are consistent with Einstein general or special relativity, or with the Lorentz transformations alone.

Peters, H. E.

Characteristics of advanced hydrogen maser frequency standards

Measurements with several operational atomic hydrogen maser standards have been made which illustrate the fundamental characteristics of the maser as well as the analysability of the corrections which are made to relate the oscillation frequency to the free, unperturbed, hydrogen standard transition frequency. Sources of the most important perturbations, and the magnitude of the associated errors, are discussed. A variable volume storage bulb hydrogen maser is also illustrated which can provide on the order of 2 parts in 10 to the 14th power or better accuracy in evaluating the wall shift. Since the other basic error sources combined contribute no more than approximately 1 part in 10 to the 14th power uncertainty, the variable volume storage bulb hydrogen maser will have net intrinsic accuracy capability of the order of 2 parts in 10 to the 14th power or better. This is an order of magnitude less error than anticipated with cesium standards and is comparable to the basic limit expected for a free atom hydrogen beam resonance standard.

Peters, H. E.

NASA hydrogen maser accuracy and stability in relation to world standards

Frequency comparisons were made among five NASA hydrogen masers in 1969 and again in 1972 to a precision of one part in 10 to the 13th power. Frequency comparisons were also made between these masers and the cesium-beam ensembles of several international standards laboratories. The hydrogen maser frequency stabilities as related to IAT were comparable to the frequency stabilities of individual time scales with respect to IAT. The relative frequency variations among the NASA masers, measured after the three-year interval, were 2 + or - 2 parts in 10 to the 13th power. Thus time scales based on hydrogen masers would have excellent long-term stability and uniformity.

Peters, H. E.

Characteristics of advanced hydrogen maser frequency standards

In house research and development at Goddard Space Flight Center to provide advanced frequency and time standards for the most demanding applications is concentrated primarily in field operable atomic hydrogen masers. Some of the most important goals for the new maser designs have been improved long and short term stability, elimination of the need for auto tuning, increased maser oscillation level, improved hydrogen economy, increased operational life, minimization of operator control or monitoring, improvement in magnetic isolation or sensitivity, and reduction in size and weight. New design concepts which have been incorporated in these masers to achieve these goals are described. The basic maser assemblies and control systems have recently been completed; the masers are oscillating; and operational testing has begun. Data illustrating the improvements in maser performance was available and presented.

Peters, H. E.

NASA hydrogen maser accuracy and stability in relation to world standards

Frequency comparisons were made among five NASA hydrogen masers to a precision of one part in 10 to the 13th power. Frequency comparisons were also made between these masers and the cesium-beam ensembles of several international standards laboratories. The hydrogen maser frequency stabilities as related to the international time scale (IAT) were comparable to the frequency stabilities of individual time scales with respect to IAT. The relative frequency variations among the NASA masers were 2 plus or minus 2 parts in 10 to the 13th power after a three year interval. Charts are developed to show the results of the accuracy tests.

Peters, H. E.

Absolute frequency of an atomic hydrogen maser clock

An accurate determination was made of the unperturbed atomic hydrogen ground state hyperfine transition frequency (F=1,m=0 - F=0,m=0) in reference to present world wide realizations of internationally defined time interval. In relation to the international atomic time system, the composite value is 1,420,405,751.7755 plus or minus 0.0031 HZ.

Peters, H. E.

Hydrogen as an atomic beam standard

After a preliminary discussion of feasibility, new experimental work with a hydrogen beam is described. A space focused magnetic resonance technique with separated oscillatory fields is used with a monochromatic beam of cold hydrogen atoms which are selected from a higher temperature source. The first resonance curves and other experimental results are presented. These results are interpreted from the point of view of accuracy potential and frequency stability, and are compared with hydrogen maser and cesium beam capabilities.

Peters, H. E.

Topics in atomic hydrogen standard research and applications

Hydrogen maser based frequency and time standards have been in continuous use at NASA tracking stations since February 1970, while laboratory work at Goddard has continued in the further development and improvement of hydrogen masers. Concurrently, experimental work has been in progress with a new frequency standard based upon the hydrogen atom using the molecular beam magnetic resonance method. Much of the hydrogen maser technology is directly applicable to the new hydrogen beam standard, and calculations based upon realistic data indicate that the accuracy potential of the hydrogen atomic beam exceeds that of either the cesium beam tube or the hydrogen maser, possibly by several orders of magnitude. In addition, with successful development, the hydrogen beam standard will have several other performance advantages over other devices, particularly exceptional stability and long continuous operating life. Experimental work with a new laboratory hydrogen beam device has recently resulted in the first resonance transition curves, measurements of relative state populations, beam intensities, etc. The most important aspects of both the hydrogen maser and the hydrogen beam work are covered.

Peters, H. E.

An improved atomic hydrogen frequency and time standard

Use of a large bulb, long-multipole magnet, automatic tuner and aluminum cavity provides an improved hydrogen maser which is accurate over long periods of time and suitable for tracking station environments.

Mc Gunigal, T. E.