Engineering Papers⌕ Search

Engineering topics

Peeters, S. J. M.

Publications and source records attributed to Peeters, S. J. M..

At least 19 records

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study on the accidental background of the JSNS$^2$ experiment

JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that searches for sterile neutrinos via the observation of $\overline{v}$ μ → $\overline{v}$ e appearance oscillations using muon decay-at-rest neutrinos. The JSNS 2 experiment performed data taking from 2021. In this manuscript, a study of the accidental background is presented. The rate of the accidental background is (9.29 ± 0.39) x 10 –8 /spill with 0.75 MW beam power and comparable to the expected number of signal events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Event-by-event direction reconstruction of solar neutrinos in a high light-yield liquid scintillator

The direction of individual B 8 solar neutrinos has been reconstructed using the SNO + liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with the solar angle. The observation was aided by a period of low primary fluor concentration that resulted in a slower scintillator decay time. This is the first time that event-by-event direction reconstruction in high light-yield liquid scintillator has been demonstrated in a large-scale detector. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A laserball calibration device for the SNO+ scintillator phase

Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence of Antineutrinos from Distant Reactors Using Pure Water at SNO+

The SNO+ Collaboration reports the first evidence of reactor antineutrinos in a Cherenkov detector. The nearest nuclear reactors are located 240 km away in Ontario, Canada. Here, this analysis uses events with energies lower than in any previous analysis with a large water Cherenkov detector. Two analytical methods are used to distinguish reactor antineutrinos from background events in 190 days of data and yield consistent evidence for antineutrinos with a combined significance of 3.5 σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of the correlated background for a sterile neutrino search using the first dataset of the JSNS$^2$ experiment

JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of ν¯ μ → ν¯ e appearance oscillations using muon decay-at-rest neutrinos. Before dedicated data taking in the first-half of 2021, we performed a commissioning run for 10 days in June 2020. Using the data obtained in this commissioning run, in this paper, we present an estimate of the correlated background which imitates the ν¯ e signal in a sterile neutrino search. In addition, in order to demonstrate future prospects of the JSNS 2 experiment, possible pulse shape discrimination improvements towards reducing cosmic ray induced fast neutron background are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The JSNS 2 detector

The JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV 2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this study, we describe the JSNS detector design, construction, and operation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electromagnetic backgrounds and potassium-42 activity in the DEAP-3600 dark matter detector

The DEAP-3600 experiment is searching for weakly interacting massive particles dark matter with a 3.3 × 10 3 kg single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is kilo electron volt–scale 40 Ar nuclear recoils producing 128 nm LAr scintillation photons observed by photomultiplier tubes. The largest backgrounds in DEAP-3600 are electronic recoils (ERs) induced by β and γ rays originating from internal and external radioactivity in the detector material. A background model of the ER interactions in DEAP-3600 was developed and is described in this work. The model is based on several components which are expected from radioisotopes in the LAr, from ex situ material assay measurements, and from dedicated independent in situ analyses. This prior information is used in a Bayesian fit of the ER components to a 247.2 d dataset to model the radioactivity in the surrounding detector materials. Pulse-shape discrimination separates ER and NR events. However, detailed knowledge of the ER background and activity of detector components sets valuable constraints on NR backgrounds including neutrons and alphas. In addition, the activity of 42 Ar in LAr in DEAP-3600 is determined by measuring the daughter decay of 42 K. Finally, this cosmogenically activated trace isotope is a relevant background at higher energies for other rare event searches using atmospheric argon, e.g., DarkSide-20k, GERDA, or LEGEND. The specific activity of 42 Ar in the atmosphere is found to be 40.4 ± 5.9 μ Bq/kg of argon.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraints on neutrino lifetime from the Sudbury Neutrino Observatory

The long baseline between Earth and the Sun makes solar neutrinos an excellent test beam for exploring possible neutrino decay. The signature of such decay would be an energy-dependent distortion of the traditional survival probability which can be fit for using well-developed and high-precision analysis methods. Here a model including neutrino decay is fit to all three phases of $^{8}\mathrm{B}$ solar neutrino data taken by the Sudbury Neutrino Observatory (SNO). This fit constrains the lifetime of neutrino mass state ${{\nu}}_{2}$ to be > $8.08\times{}{10}^{{-}5}\text{ }\text{ }\mathrm{s}/\mathrm{eV}$ at 90% confidence. An analysis combining this SNO result with those from other solar neutrino experiments results in a combined limit for the lifetime of mass state ${{\nu}}_{2}$ of > $1.92\times{}{10}^{{-}3}\text{ }\text{ }\mathrm{s}/\mathrm{eV}$ at 90% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. Finally, the characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of the DEAP-3600 dark matter detector

The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is 10 –46 cm 2 for a 100 GeV/c 2 WIMP mass with a fiducial exposure of 3 tonne-years. In conclusion, this paper describes the physical properties and construction of the DEAP-3600 detector.

79 ASTRONOMY AND ASTROPHYSICS↗