Engineering PapersSearch

Engineering topics

Peckham, G. E.

Publications and source records attributed to Peckham, G. E..

At least 19 records

Validation of UARS Microwave Limb Sounder Ozone Measurements

This paper describes the validation of ozone data from the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS). The MLS ozone retrievals are obtained from the calibrated microwave radiances (emission spectra) in two separate bands, at frequencies near 205 and 183 GHz. Analyses described here focus on the MLS Version 3 data (the first set of files made publicly available). We describe results of simulations performed to assess the quality of the retrieval algorithms, in terms of both mixing ratio and radiance closure. From actual MLS observations, the 205-GHz ozone retrievals give better closure (smaller radiance residuals) than that from the 183-GHz measurements and should be considered more accurate from the calibration aspects. However, the 183-GHz data are less noise limited in the mesosphere and can provide the most useful scientific results in that region. We compare the retrieved 205-GHz ozone profiles in the middle-to lower stratosphere to ozonesonde measurements at a wide range of latitudes and seasons. Ground-based lidar data from Table Mountain, California, provide a good reference for comparisons at higher altitudes. Based on these analyses, comparisons with balloon-borne measurements and others, as well as a detailed budget of estimated uncertainties, MLS results appear to be generally of high quality, with some biases worth mentioning. Results for the lowermost stratosphere (approx. 50 to 100 bPa) are still in need of improvement. A set of estimated precision and accuracy values is derived for the MLS ozone data sets. We also comment on recent updates in the retrieval algorithms and their impact on ozone values.

Froidevaux, L.

Validation of UARS Microwave Limb Sounder 183 GHz H2O Measurements

The Upper Atmosphere Research Satellite (UARS) microwave limb sounder (MLS) makes measurements of thermal emission at 183.3 GHz which are used to infer the concentration of water vapor over a pressure range of 46-0.2hPa (approximately 20-60 km). We provide a validation of MLS H2O by analyzing the integrity of the measurements, by providing an error characterization, and by comparison with data from other instruments. It is estimated that version 3 MLS H2O retrievals are accurate to within 20-25% in the lower stratosphere and to within 8-13% in the upper stratosphere and lower mesosphere. The precision of a single profile is estimated to be approximately 0.15 parts per million by volume (ppmv) in the midstratosphere and 0.2 ppmv in the lower and upper stratosphere. In the lower mesosphere the estimate of a single profile precision is 0.25-0.45 ppmv. During polar winter conditions, H2O retrievals at 46 hPa can have a substantial contribution from climatology. The vertical resolution of MLS H2O retrievals is approximately 5 km.

Lahoz, W. A.

Calibration of the Microwave Limb Sounder on the Upper Atmosphere Research Satellite

The Microwave Limb Sounder (MLS) is a three-radiometer, passive, limb emission instrument onboard the Upper Atmosphere Research Satellite (UARS). Radiometric, spectral and field-of-view calibrations of the MLS instrument are described in this paper. In-orbit noise performance, gain stability, spectral baseline and dynamic range are described, as well as use of in-flight data for validation and refinement of prelaunch calibrations. Estimated systematic scaling uncertainties (3 sigma) on calibrated limb radiances from prelaunch calibrations are 2.6% in bands 1 through 3, 3.4% in band 4, and 6% in band 5. The observed systematic errors in band 6 are about 15%, consistent with prelaunch calibration uncertainties. Random uncertainties on individual limb radiance measurements are very close to the levels predicted from measured radiometer noise temperature, with negligible contribution from noise and drifts on the regular in-flight gain calibration measurements.

Jarnot, R. F.

Validation of UARS MLS 183 GHz H(sub 2)O Measurements

We provide a validation of MLS H(sub 2)O by analyzing the integrity of the measurements, by providing an error characterization and by comparison with data from other instruments. This paper concerns the data validation of middle atmosphere distributions of H(sub 2)O as measured by the Midrowave Limb Sounder (MLS).

thermal emission UARS energy balance of the middle

Tropical stratospheric water vapor measured by the microwave limb sounder (MLS)

The lower stratospheric variability of equatorial water vapor, measured by the Microwave Limb Sounder (MLS), follows an annual cycle modulated by the quasi-biennial oscillation. At levels higher in the stratosphere, water vapor measurements exhibit a semi-annual oscillatory signal with the largest amplitudes at 2.2 and 1hPa. Zonal-mean cross sections of MLS water vapor are consistent with previous satellite measurements from the limb infrared monitor of the stratosphere (LIMS) and the stratospheric Aerosol and Gas Experiment 2 (SAGE 2) instruments in that they show water vapor increasing upwards and the polewards from a well defined minimum in the tropics. The minimum values vary in height between the retrieved 46 and 22hPa pressure levels.

Carr, E. S.

Interhemispheric differences in polar stratospheric HNO3, H2O, ClO, and O3

Simultaneous global measurements of nitric acid (HNO3), water (H2O), chlorine monoxide (ClO), and ozone (O3) in the stratosphere have been obtained over complete annual cycles in both hemispheres by the Microwave Limb Sounder on the Upper Atmosphere Research Satellite. A sizeable decrease in gas-phase HNO3 was evident in the lower stratospheric vortex over Antarctica by early June 1992, followed by a significant reduction in gas-phase H2O after mid-July. By mid-August, near the time of peak ClO, abundances of gas-phase HNO3 and H2O were extremely low. The concentrations of HNO3 and H2O over Antarctica remained depressed into November, well after temperatures in the lower stratosphere had risen above the evaporation threshold for polar stratospheric clouds, implying that denitrification and dehydration had occurred. No large decreases in either gas-phase HNO3 or H2O were observed in the 1992-1993 Arctic winter vortex. Although ClO was enhanced over the Arctic as it was over the Antarctic, Arctic O3 depletion was substantially smaller than that over Antarctica. A major factor currently limiting the formation of an Arctic ozone 'hole' is the lack of denitrification in the northern polar vortex, but future cooling of the lower stratosphere could lead to more intense denitrification and consequently larger losses of Arctic ozone.

Santee, M. L.

Validation of UARS MLS Ozone Measurements

This paper describes the validation of ozone data from the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS). The MLS ozone retrievals are obtained from the calibrated microwave radiances (emission spectra) in two separate bands, at frequencies near 205 and 183 GHz.

Microwave Limb Sounder (MLS)

Interhemispheric Differences in Dentifrication and Related Processes Affecting Polar Ozone

The severe depletion of stratospheric ozone over Antarctica in late winter and early spring is caused by enhanced CLO abundances arising from heterogeneous reactions on polar stratospheric clouds (PSCs). CLO abundances comparable to those over Antarctica have also been observed throughout the Arctic Vortex, but the accompanying loss of Arctic ozone has been much less severe.

ozone depletion

Northern hemisphere mid-stratosphere vortex processes diagnosed from H2O, N2O and potential vorticity

Microwave Limb Sounder (MLS) H2O Cryogenic Limb Array Etalon Spectrometer (CLAES) N2O and potential vorticity calculated from UK Meteorological Office data are used to study mid-stratospheric vortex processes in the northern hemisphere winter of 1991-1992. Areas of moist air (at approx. 20 hPa) and N2O-poor air (at approx. 10hPa) are well-correlated with high values of potential vorticity and there is little or no large scale mixing across the vortex edge. We find evidence for the descent of relatively dry mesospheric air to the 840 K (approx. 10 hPa) level, as well as descent of moist air from the upper stratosphere to the 655 K (approx. 20 hPa) level. A reduction in the areas of the vortex and both the moist and H2O-poor regions is observed and there is evidence of moist and N2O-poor air parcels being extruded from the vortex.

Lahoz, W. A.

Springtime stratospheric water vapour in the Southern Hemisphere as measured by MLS

The effects of the break-up of the Antarctic vortex on the water vapor distribution are studied using MLS measurements of water vapor made during September 1991 and November 1991. In early November at 22 hPa a moist area is found within the polar vortex, consistent with an observed descent of order 10 km and strong radiative cooling. As the vortex erodes (beginning of November 1991), parcels of moist air become detached from the edge of the vortex and mix rapidly (within 2-3 days) with drier mid-latitude air. When the vortex breaks up (mid-November), larger parcels of moist air from both the edge and the inner vortex migrate to mid-latitudes. These parcels have a longer lifetime than those produced by vortex erosion, probably because they are correlated with higher potential vorticity gradients. The break-up of the vortex is accompanied by a mean adiabatic equatorward transport resulting in a significant increase in midstratospheric water vapor values at mid-latitudes in late spring.

Harwood, R. S.

The microwave limb sounder for the Upper Atmosphere Research Satellite

The Microwave Limb Sounder was designed to map the concentrations of trace gases from the stratosphere to the lower thermosphere, to improve understanding of the photochemical reactions which take place in this part of the atmosphere. The instrument will measure the intensity of thermal radiation from molecules in the atmosphere at frequencies corresponding to rotational absorption bands of chlorine monoxide, ozone, and water vapor. Molecular concentration profiles will be determined over a height range of 15 to 80 km (20 to 45 km for C10). The 57 deg inclination orbit proposed for the Upper Atmosphere Research Satellite will allow global coverage.

Waters, J. W.

Microwave Atmospheric-Pressure Sensor

Report describes tests of microwave pressure sounder (MPS) for use in satellite measurements of atmospheric pressure. MPS is multifrequency radar operating between 25 and 80 GHz. Determines signal absorption over vertical path through atmosphere by measuring strength of echoes from ocean surface. MPS operates with cloud cover, and suitable for use on current meteorological satellites.

Flower, D. A.

Experimental validation of a millimeter wave radar technique to remotely sense atmospheric pressure at the Earth's surface

Experiments with a millimeter wave radar operating on the NASA CV-990 aircraft which validate the technique for remotely sensing atmospheric pressure at the Earth's surface are described. Measurements show that the precise millimeter wave observations needed to deduce pressure from space with an accuracy of 1 mb are possible, that sea surface reflection properties agree with theory and that the measured variation of differential absorption with altitude corresponds to that expected from spectroscopic models.

Flower, D. A.

The design of optimum remote-sensing instruments

Remote-sensing instruments allow values for certain properties of a target to be retrieved from measurements of radiation emitted, reflected or transmitted by the target. The retrieval accuracy is affected by random variations in the many target properties which affect the measurements. A method is described, by which statistical properties of the target and theoretical models of its electromagnetic behavior can be used to choose values for the instrument parameters which maximize the retrieval accuracy. The technique is applicable to a wide range of remote-sensing instruments.

Peckham, G. E.

Optimizing a remote sensing instrument to measure atmospheric surface pressure

Atmospheric surface pressure can be remotely sensed from a satellite by an active instrument which measures return echoes from the ocean at frequencies near the 60 GHz oxygen absorption band. The instrument is optimized by selecting its frequencies of operation, transmitter powers and antenna size through a new procedure baesd on numerical simulation which maximizes the retrieval accuracy. The predicted standard deviation error in the retrieved surface pressure is 1 mb. In addition the measurements can be used to retrieve water vapor, cloud liquid water and sea state, which is related to wind speed.

Peckham, G. E.

A microwave pressure sounder

A technique for the remote measurement of atmospheric surface pressure will be described. Such measurements could be made from a satellite in polar orbit and would cover many areas for which conventional meteorological data are not available. An active microwave instrument is used to measure the strength of return echoes from the ocean surface at a number of frequencies near the 60 GHz oxygen absorption band. Factors which affect the accuracy with which surface pressure can be deduced from these measurements will be discussed and an instrument designed to test the method by making measurements from an aircraft will be described.

Peckham, G. E.

Microwave measurement of atmospheric pressure

Proposed concept for measuring surface air pressure over ocean utilizes three pairs of microwave signals transmitted from orbiting satellite. Measurements are used for long range weather forecasting.

Flower, D. A.

A microwave pressure sounder for the remote measurement of atmospheric surface pressure

An instrument to measure atmospheric pressure at the Earth's surface from an orbiting satellite is considered. Surface pressure can be deduced from measurements of the transmission of an atmospheric column at several frequencies at the edges of the 60 GHz oxygen absorption band. An active microwave instrument proposed to make these measurements is the subject of a joint UK-US development program to demonstrate its capabilities. The results of an extensive analysis of the potential performance of the instrument are summarized.

Flower, D. A.