Evaluation and characterization of hybrid arrays

An Infrared Camera was built for astronomical observations and for testing arrays for satellite based work. The detectors are sensitive to mid infrared wavelengths. The camera was tested at the University of Arizona 61 and 90 inch telescopes and the NASA IRTF. These tests have demonstrated a sensitivity consistent with photon shot noise with an approximately 10% quantum efficiency for each pixel when the camera was used with a 1.6% spectral filter or when used with a Fabry-Perot having a resolving power of 2000. Initial measurements of read out noise, dark current, cross talk, and hysteresis were made. The detector chip in current use is a hybrid array manufactured by the Hughes Aircraft Company. Because part of the goal was to develop and advance technology, it was decided to work with a switched MOSFET array. This architecture is very promising, and the detector parameters will be quantified carefully.

Arens, J. F.↗

High spatial resolution observations of NGC 7027 with a 10 micron array camera

First observations of a planetary nebula with an infrared charge injection device (CID) array camera are reported. The 10 micron images of NGC 7027 have spatial resolution comparable to that of the highest resolution (less than 2 arcsec) radio aperture-synthesis maps of this source. A much closer correspondence between the mid-infrared and radio appearance of NGC 7027 was found than was known previously, confirming that warm dust is coextensive and well mixed with the gas in the ionized zone. Using maps at three wavelengths, the spatial dependence of the shape of the 8-13 micron spectrum within the nebula is examined. The dip at 9.60 microns is shallowest in regions of enhanced optical extinction (as determined from new images near 4000 and 9000 A obtained with an optical charge coupled device). The 9.60 micron emission is strongest in these same positions. It is shown that the results may be explained not by silicate absorption, but by a combination of emission from two distinct grain populations, one of which is also partly responsible for the variation in extinction across the nebula.

Arens, J. F.↗

Infrared camera for 10-micron astronomy

An infrared imaging photometer employing a monolithic 32 x 32 pixel bismuth doped silicon charge injection device array is described. The device is primarily useful in the 8-13-micron atmospheric window. The detector is sufficiently sensitive to provide good performance on ground-based telescopes and promises to be very good for low background space flight operation.

Arens, J. F.↗