Engineering Papers⌕ Search

Engineering topics

Paul, A

Publications and source records attributed to Paul, A.

SU-C-202-02: A Comprehensive Evaluation of Adaptive Daily Planning for Cervical Cancer HDR Brachytherapy

Purpose: To evaluate adaptive daily planning for cervical cancer patients who underwent high-dose-rate intra-cavitary brachytherapy (HDR-ICBT). Methods: This study included 22 cervical cancer patients who underwent 5 fractions of HDR ICBT. Regions of interest (ROIs) including high-risk clinical tumor volume (HR-CTV) and organs-at-risk (OARs) were manually contoured on daily CT images. All patients were treated with adaptive daily plans, which involved ROI delineation and dose optimization at each treatment fraction. Single treatment plans were retrospectively generated by applying the first treatment fraction’s dwell times adjusted for decay and dwell positions of the applicator to subsequent treatment fractions. Various existing similarity metrics were calculated for the ROIs to quantify interfractional organ variations. A novel similarity score (JRARM) was established, which combined both volumetric overlap metrics (DSC, JSC, and RVD) and distance metrics (ASD, MSD, and RMSD). Linear regression was performed to determine a relationship between inter-fractional organ variations of various similarity metrics and D2cc variations from both plans. Wilcoxon Signed Rank Tests were used to assess adaptive daily plans and single plans by comparing EQD2 D2cc (α/β=3) for OARs. Results: For inter-fractional organ variations, the sigmoid demonstrated the greatest variations based on the JRARM and DSC similarity metrics. Comparisons between paired ROIs showed differences in JRARM scores and DSCs at each treatment fraction. RVD, MSD, and RMSD were found to be significantly correlated to D2cc variations for bladder and sigmoid. The comparison between plans found that adaptive daily planning provided lower EQD2 D2cc of OARs than single planning, specifically for the sigmoid (p=0.015). Conclusion: Substantial inter-fractional organ motion can occur during HDR-BT, which may significantly affect D2cc of OARs. Adaptive daily planning provides improved dose sparing for OARs compared to single planning.

60 APPLIED LIFE SCIENCES↗

WE-AB-207B-04: A Preliminary Investigation of Indicators for Treatment Outcomes of CT Guided Cervical Cancer Brachytherapy

Purpose: To identify indicators for recurrence in cervical cancer patients treated with high-dose-rate brachytherapy (HDR-BT). Methods: A total of 37 biopsy proven uterine cervical cancer patients of stage IB-IVA treated between 2011 and 2015 were included in this study. All patients were treated with 37.8–52.2Gy of external beam radiotherapy (EBRT) plus 5 × 5.0–6.5Gy of HDR-BT. Patient age, standard deviation of high-risk clinical tumor volume (HR-CTVSD) collected throughout HDR-BT, and D90 (EQD2, α/β=10Gy) of the HR-CTV were investigated as potential indicators for local/distant recurrence using ROC analysis. The optimal cutoff value was identified through the Youden index and was subsequently used to obtain a group assignment for all patients. Another two comparing groups were defined per evidence of post-EBRT tumor shrinkage based on the pre-HDR MR scan. Kaplan-Meier curves were generated for recurrence-free proportions for comparing groups where time was measured from the final HDR treatment date to the date of the final follow-up exam and compared through Cox regression. Results: Patients had a median follow-up of 12 months, where 16% had local pelvic recurrence and 16% had distant recurrence. HR-CTVSD was identified as a statistically significant indicator for recurrence (AUC=0.802, p=0.007) compared to D90 (AUC=0.655, p=0.167) and patient age (AUC=0.683, p=0.103). HR-CTVSD of 6.26cc was chosen as the optimal cutoff value, which was used as the basis for patient group assignment. Patients with HR-CTVSD>6.26cc had a hazard ratio of 3.92 (95% CI-1.37, 11.24; p=0.011) for recurrence compared to HRCTVSD≤ 6.26cc. Patients without evidence of post-EBRT tumor shrinkage compared to those with had a hazard ratio of 4.28 (95% CI-1.14, 16.15; p=0.032) for recurrence. Conclusion: HR-CTVSD was identified as an indicator for recurrence and an optimal value of 6.26cc was established in our study. In addition, patients without evidence of post-EBRT tumor shrinkage demonstrated an increased recurrence rate.

60 APPLIED LIFE SCIENCES↗

Measurement and simulation of anisotropic magnetoresistance in single GaAs/MnAs core/shell nanowires

We report four probe measurements of the low field magnetoresistance (MR) in single core/shell GaAs/MnAs nanowires (NWs) synthesized by molecular beam epitaxy, demonstrating clear signatures of anisotropic magnetoresistance that track the field-dependent magnetization. A comparison with micromagnetic simulations reveals that the principal characteristics of the magnetoresistance data can be unambiguously attributed to the nanowire segments with a zinc blende GaAs core. The direct correlation between magnetoresistance, magnetization, and crystal structure provides a powerful means of characterizing individual hybrid ferromagnet/semiconductor nanostructures.

36 MATERIALS SCIENCE↗

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, SiC photoconductive switches and compact proton sources. Applications of the DWA accelerator to problems in homeland security will also be discussed.

43 PARTICLE ACCELERATORS↗

Design of Annulated Pyrazoles As Inhibitors of HIV-1 Reverse Transcriptase

Non-nucleoside reverse transcriptase inhibitors (NNRTIs) are recommended components of preferred combination antiretroviral therapies used for the treatment of HIV. These regimens are extremely effective in suppressing virus replication. Structure-based optimization of diaryl ether inhibitors led to the discovery of a new series of pyrazolo[3,4-c]pyridazine NNRTIs that bind the reverse transcriptase enzyme of human immunodeficiency virus-1 (HIV-RT) in an expanded volume relative to most other inhibitors in this class. The binding mode maintains the {beta}13 and {beta}14 strands bearing Pro236 in a position similar to that in the unliganded reverse transcriptase structure, and the distribution of interactions creates the opportunity for substantial resilience to single point mutations. Several pyrazolopyridazine NNRTIs were found to be highly effective against wild-type and NNRTI-resistant viral strains in cell culture.

59 BASIC BIOLOGICAL SCIENCES↗

STATUS OF THE DIELECTRIC WALL ACCELERATOR

The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.

43 PARTICLE ACCELERATORS↗