Engineering Papers⌕ Search

Engineering topics

Patel, S. G.

Publications and source records attributed to Patel, S. G..

Radiatively cooled magnetic reconnection experiments driven by pulsed power

We present evidence for strong radiative cooling in a pulsed-power-driven magnetic reconnection experiment. Two aluminum exploding wire arrays, driven by a 20 MA peak current, 300 ns rise time pulse from the Z machine (Sandia National Laboratories), generate strongly driven plasma flows (MA≈7) with anti-parallel magnetic fields, which form a reconnection layer (SL≈120) at the mid-plane. The net cooling rate far exceeds the Alfvénic transit rate (τcool−1/τA−1≫1), leading to strong cooling of the reconnection layer. We determine the advected magnetic field and flow velocity using inductive probes positioned in the inflow to the layer, and inflow ion density and temperature from analysis of visible emission spectroscopy. A sharp decrease in x-ray emission from the reconnection layer, measured using filtered diodes and time-gated x-ray imaging, provides evidence for strong cooling of the reconnection layer after its initial formation. X-ray images also show localized hotspots, regions of strong x-ray emission, with velocities comparable to the expected outflow velocity from the reconnection layer. These hotspots are consistent with plasmoids observed in 3D radiative resistive magnetohydrodynamic simulations of the experiment. X-ray spectroscopy further indicates that the hotspots have a temperature (170 eV) much higher than the bulk layer (≤75 eV) and inflow temperatures (about 2 eV) and that these hotspots generate the majority of the high-energy (>1 keV) emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasmoid Formation and Strong Radiative Cooling in a Driven Magnetic Reconnection Experiment

Herein we present the first experimental study of plasmoid formation in a magnetic reconnection layer undergoing rapid radiative cooling, a regime relevant to extreme astrophysical plasmas. Two exploding aluminum wire arrays, driven by the Z machine, generate a reconnection layer (S L ≈ 120) in which the cooling rate far exceeds the hydrodynamic transit rate (τ hydro =τ cool > 100). The reconnection layer generates a transient burst of >1 keV x-ray emission, consistent with the formation and subsequent rapid cooling of the layer. Time-gated x-ray images show fast-moving (up to 50 km s –1 ) hotspots in the layer, consistent with the presence of plasmoids in 3D resistive magnetohydrodynamic simulations. X-ray spectroscopy shows that these hotspots generate the majority of Al K-shell emission (around 1.6 keV) prior to the onset of cooling, and exhibit temperatures (170 eV) much greater than that of the plasma inflows and the rest of the reconnection layer, thus providing insight into the generation of high-energy radiation in radiatively cooled reconnection events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of switch diagnostics on the MAIZE linear transformer driver

The MAIZE Linear Transformer Driver is made of 40 capacitor-switch-capacitor `bricks' connected in parallel. When these 40 bricks are charged to 100-kV and then discharged synchronously, the MAIZE facility generates a 1-MA current pulse with a 100-ns rise time into a matched load impedance. Discharging each of the capacitors in a brick is carried out by the breakdown of a spark-gap switch, a process which results in the emission of light. Monitoring this output light with a fiber optic coupled to a photomultiplier tube (PMT) and an oscilloscope channel provides information on switch performance and timing jitter– whether a switch red early, late, or in phase with the other switches. However, monitoring each switch with a dedicated detector- oscilloscope channel can be problematic for facilities where the number of switches to be monitored (e.g., 40 on MAIZE) greatly exceeds the number of detector-oscilloscope channels available. The technique of using fibers to monitor light emission from switches can be optimized by treating a PMT as a binary digit or bit and using a combinatorial encoding scheme, where each switch is monitored by a unique combination of fiber- PMT-oscilloscope channels simultaneously. By observing the unique combination of ber-PMT-oscilloscope channels that are turned on, the pre-firing or late-firing of a single switch on MAIZE can be identified by as few as six PMT-oscilloscope channels. The number of PMT-oscilloscope channels, N , required to monitor X switches can be calculated by 2 N = X + 1, where the number '2' is selected because the PMT-oscilloscope acts as a bit. Here, we demonstrate the use of this diagnostic technique on MAIZE. In conclusion, we also present an analysis of how this technique could be scaled to monitor the tens of thousands of switches proposed for various next generation pulsed power facilities.

47 OTHER INSTRUMENTATION↗