Engineering PapersSearch

Engineering topics

Pasquale, Bert

Publications and source records attributed to Pasquale, Bert.

Alignment and Test of the Wide Field Infrared Survey Telescope (WFIRST) Engineering Design Unit (EDU) Grism

The WFIRST wide field instrument (WFI) includes a slitless spectrometer, which plays an important role in the WFIRST mission for the survey of emission-line galaxies. WFI is building engineering design and environmental test (EDU and ETU) units to reduce risk for the flight grism unit. We report here on successful build and test of the EDU grism. The four-element EDU grism consists of two prism elements and two diffractive elements that provide R700 dispersion. The elements were fabricated with alignment fiducials and integral flats to allow opto-mechanical alignment in six-degrees of freedom. Each element in turn, was installed onto a hexapod and positioned to its nominal orientation relative to the grism deck, then bonded into individual cells. Alignment measurements were performed in situ using theodolites to set tip/tilt and a Micro-vu non-contact Multisensor Measurement System was used to set despace, decenter and clocking of each element using the hexapod. After opto-mechanical alignment, the grism wavefront was measured using an Infrared ZYGO interferometer at various field points extending over a 20 by 14- degree (local) field of view. Using modeled alignment sensitivities, we determined the alignment correction required on our Element 2 prism compensator and successfully minimized the field dependent wavefront error and confocality. This paper details the alignment and testing of the EDU grism at ambient and cold operating temperatures.

Hagopian, John

Multispectral Snapshot Imagers Onboard Small Satellite Formations for Multi-Angular Remote Sensing

Multispectral snapshot imagers are capable of producing 2D spatial images with a single exposure at selected, numerous wavelengths using the same camera, therefore operate differently from push broom or whiskbroom imagers. They are payloads of choice in multi-angular, multi-spectral imaging missions that use small satellites flying in controlled formation, to retrieve Earth science measurements dependent on the targets Bidirectional Reflectance-Distribution Function (BRDF). Narrow fields of view are needed to capture images with moderate spatial resolution. This paper quantifies the dependencies of the imagers optical system, spectral elements and camera on the requirements of the formation mission and their impact on performance metrics such as spectral range, swath and signal to noise ratio (SNR). All variables and metrics have been generated from a comprehensive, payload design tool. The baseline optical parameters selected (diameter 7 cm, focal length 10.5 cm, pixel size 20 micron, field of view 1.15 deg) and snapshot imaging technologies are available. The spectral components shortlisted were waveguide spectrometers, acousto-optic tunable filters (AOTF), electronically actuated Fabry-Perot interferometers, and integral field spectrographs. Qualitative evaluation favored AOTFs because of their low weight, small size, and flight heritage. Quantitative analysis showed that waveguide spectrometers perform better in terms of achievable swath (10-90 km) and SNR (greater than 20) for 86 wavebands, but the data volume generated will need very high bandwidth communication to downlink. AOTFs meet the external data volume caps well as the minimum spectral (wavebands) and radiometric (SNR) requirements, therefore are found to be currently feasible in spite of lower swath and SNR.

Nag, Sreeja

Wide-Field InfraRed Survey Telescope (WFIRST) Slitless Spectrometer: Design, Prototype, and Results

The slitless spectrometer plays an important role in the Wide-Field InfraRed Survey Telescope (WFIRST) mission for the survey of emission-line galaxies. This will be an unprecedented very wide field, HST quality 3D survey of emission line galaxies. The concept of the compound grism as a slitless spectrometer has been presented previously. The presentation briefly discusses the challenges and solutions of the optical design, and recent specification updates, as well as a brief comparison between the prototype and the latest design. However, the emphasis of this paper is the progress of the grism prototype: the fabrication and test of the complicated diffractive optical elements and powered prism, as well as grism assembly alignment and testing. Especially how to use different tools and methods, such as IR phase shift and wavelength shift interferometry, to complete the element and assembly tests. The paper also presents very encouraging results from recent element tests to assembly tests. Finally we briefly touch the path forward plan to test the spectral characteristic, such as spectral resolution and response.

Grism

Spectral and Wavefront Error Performance of WFIRST/AFTA Prototype Filters

The Cycle 5 design baseline for the Wide-Field Infrared Survey Telescope Astrophysics Focused Telescope Assets (WFIRSTAFTA) instrument includes a single wide-field channel (WFC) instrument for both imaging and slit-less spectroscopy. The only routinely moving part during scientific observations for this wide-field channel is the element wheel (EW) assembly. This filter-wheel assembly will have 8 positions that will be populated with 6 bandpass filters, a blank position, and a Grism that will consist of a three-element assembly to disperse the full field with an undeviated central wavelength for galaxy redshift surveys. All filter elements in the EW assembly will be made out of fused silica substrates (110 mm diameter) that will have the appropriate bandpass coatings according to the filter designations (Z087, Y106, J129, H158, F184, W149 and Grism). This paper presents and discusses the performance (including spectral transmission and reflectedtransmitted wavefront error measurements) of a subset of bandpass filter coating prototypes that are based on the WFC instrument filter compliment. The bandpass coating prototypes that are tested in this effort correspond to the Z087, W149, and Grism filter elements. These filter coatings have been procured from three different vendors to assess the most challenging aspects in terms of the in-band throughput, out of band rejection (including the cut-on and cutoff slopes), and the impact the wavefront error distortions of these filter coatings will have on the imaging performance of the de-field channel in the WFIRSTAFTA observatory.

cryogenic temperatures

Optical Design of WFIRST-AFTA Wide-Field Instrument

The WFIRSTAFTA Wide-Field Infrared Survey Telescope TMA optical design provides 0.28-sq FOV at 0.11 pixel scale, operating between 0.6 2.4m, including a spectrograph mode (1.3-1.95m.) An IFU provides a discrete 3x3.15 field at 0.15 sampling.

Optical Equipment

Design, Fabrication and Test of WFIRST-AFTA GRISM Assembly

The Wide-Field Infra-Red Survey Telescope (WFIRST) is designed to perform wide-field imaging and slitless spectroscopic survey of the sky. A compound Grism assembly is selected as its slitless dispersing element. Compared to the grisms in several instruments installed on the Hubble space telescope, the challenge of this grism is the much wider Field Of View (FOV), larger dispersion, and smaller f. The image quality of the slitless spectrometer is directly related to how deep of the sky the spectrometer is able to see. This paper discusses how to use a diffractive lens surface to compensate the wavelength dependent aberration created by the grating in non-collimated space to make the spectrometer diffraction limited, as well as how to intelligently combine the two diffractive surfaces (lens and grating) to reduce the unwanted diffraction orders from the grating. The paper also discusses how to improve the diffraction efficiency of the diffractive surfaces, as well as how to align and assemble the optics.

Diffractive Optics