Engineering Papers⌕ Search

Engineering topics

Parkinson, Dilworth Y.

Publications and source records attributed to Parkinson, Dilworth Y..

Spatial control of perilacunar canalicular remodeling during lactation

Abstract Osteocytes locally remodel their surrounding tissue through perilacunar canalicular remodeling (PLR). During lactation, osteocytes remove minerals to satisfy the metabolic demand, resulting in increased lacunar volume, quantifiable with synchrotron X-ray radiation micro-tomography (SRµCT). Although the effects of lactation on PLR are well-studied, it remains unclear whether PLR occurs uniformly throughout the bone and what mechanisms prevent PLR from undermining bone quality. We used SRµCT imaging to conduct an in-depth spatial analysis of the impact of lactation and osteocyte-intrinsic MMP13 deletion on PLR in murine bone. We found larger lacunae undergoing PLR are located near canals in the mid-cortex or endosteum. We show lactation-induced hypomineralization occurs 14 µm away from lacunar edges, past a hypermineralized barrier. Our findings reveal that osteocyte-intrinsic MMP13 is crucial for lactation-induced PLR near lacunae in the mid-cortex but not for whole-bone resorption. This research highlights the spatial control of PLR on mineral distribution during lactation.

59 BASIC BIOLOGICAL SCIENCES↗

Scalable Surface Micro-Texturing of LLZO Solid Electrolytes for Battery Applications

A challenge for lithium lanthanum zirconate (LLZO)-based solid-state batteries is to increase the critical current density (CCD) to enable high current cycling. A promising strategy is to modify the LLZO surface morphology to provide a larger contact area with the Li metal. Here, a surface-textured thin LLZO electrolyte was prepared through an easily scalable process. The texturing process is a simple pressing of green LLZO tapes between micro-textured substrates. A variety of textures can be produced, depending on the type of substrate, and texturing can be on either one side or both sides. For this work, after pressing and sintering, several micro-patterns are formed on thin LLZO (~118 μm thick). The properties of the various samples were characterized to investigate the impact of surface texturing, and the most promising ones were selected for electrochemical testing in symmetrical lithium cells and full cells. Li symmetric cells using a coarse ridge-textured LLZO exhibit ~2.5 times increased CCD compared to planar non-textured LLZO, and a solid-state full cell shows stable cycling and improved rate performance. Finally, we believe this process offers a favorable trade-off of processing complexity vs structural optimization to maximize CCD.

25 ENERGY STORAGE↗

In situ X-ray and IR probes relevant to Earth science at the Advanced Light Source at Lawrence Berkeley Laboratory

Access to synchrotron X-ray facilities has become an important aspect for many disciplines in experimental Earth science. This is especially important for studies that rely on probing samples in situ under natural conditions different from the ones found at the surface of the Earth. The non-ambient condition Earth science program at the Advanced Light Source (ALS), Lawrence Berkeley National Laboratory, offers a variety of tools utilizing the infra-red and hard X-ray spectrum that allow Earth scientists to probe Earth and environmental materials at variable conditions of pressure, stress, temperature, atmospheric composition, and humidity. These facilities are important tools for the user community in that they offer not only considerable capacity (non-ambient condition diffraction) but also complementary (IR spectroscopy, microtomography), and in some cases unique (Laue microdiffraction) instruments. The availability of the ALS’ in situ probes to the Earth science community grows especially critical during the ongoing dark time of the Advanced Photon Source in Chicago, which massively reduces available in situ synchrotron user time in North America.

58 GEOSCIENCES↗

X-Ray Micro-Tomography Applied to Nasa's Materials Research: Heat Shields, Parachutes and Asteroids

X-ray micro-tomography is used to support the research on materials carried out at NASA Ames Research Center. The technique is applied to a variety of applications, including the ability to characterize heat shield materials for planetary entry, to study the Earth- impacting asteroids, and to improve broadcloths of spacecraft parachutes. From micro-tomography images, relevant morphological and transport properties are determined and validated against experimental data.

asteroids↗

X-ray Micro-Tomography of Ablative Heat Shield Materials

X-ray micro-tomography is a non-destructive characterization technique that allows imaging of materials structures with voxel sizes in the micrometer range. This level of resolution makes the technique very attractive for imaging porous ablators used in hypersonic entry systems. Besides providing a high fidelity description of the material architecture, micro-tomography enables computations of bulk material properties and simulations of micro-scale phenomena. This presentation provides an overview of a collaborative effort between NASA Ames Research Center and Lawrence Berkeley National Laboratory, aimed at developing micro-tomography experiments and simulations for porous ablative materials. Measurements are carried using x-rays from the Advanced Light Source at Berkeley Lab on different classes of ablative materials used in NASA entry systems. Challenges, strengths and limitations of the technique for imaging materials such as lightweight carbon-phenolic systems and woven textiles are discussed. Computational tools developed to perform numerical simulations based on micro-tomography are described. These enable computations of material properties such as permeability, thermal and radiative conductivity, tortuosity and other parameters that are used in ablator response models. Finally, we present the design of environmental cells that enable imaging materials under simulated operational conditions, such as high temperature, mechanical loads and oxidizing atmospheres.Keywords: Micro-tomography, Porous media, Ablation

tomography↗