Engineering PapersSearch

Engineering topics

Parker, T. E.

Publications and source records attributed to Parker, T. E..

Instantaneous velocity field imaging instrument for supersonic reacting flows

The technical tasks conducted to develop and demonstrate a new gas velocity measurement technique for high enthalpy reacting flows is described. The technique is based on Doppler-shifted Planar Laser-induced Fluorescence (PLIF) imaging of the OH radical. The imaging approach permits, in principle, single-shot measurements of the 2-D distribution of a single velocity component in the measurement plane, and is thus a technique of choice for applications in high enthalpy transient flow facilities. In contrast to previous work in this area, the present program demonstrated an approach which modified the diagnostic technique to function under the constraints of practical flow conditions of engineering interest, rather than vice-versa. In order to accomplish the experimental demonstrations, the state-of-the-art in PLIF diagnostic techniques was advanced in several ways. Each of these tasks is described in detail and is intended to serve as a reference in supporting the transition of this new capability to the fielded PLIF instruments now installed at several national test facilities. Among the new results of general interest in LlF-based flow diagnostics, a detailed set of the first measurements of the collisional broadening and shifting behavior of OH (1,0) band transitions in H7-air combustion environments is included. Such measurements are critical in the design of a successful strategy for PLIF velocity imaging; they also relate to accurate concentration and temperature measurements, particularly in compressible flow regimes. Furthermore, the results shed new light on the fundamental relationship between broadening and energy transfer collisions in OH A(sup 2)Sigma(+)v(sup ') = 1. The first single-pulse, spectrally-resolved measurements of the output of common pulsed dye lasers were also produced during the course of this effort. As with the OH broadening measurements, these data are a significant aspect of a successful velocity imaging strategy, and also have potential implications for many other LIF measurement techniques. Our results indicated the need to modify the commercially available laser cavity in order to accommodate the constraints imposed by typical SCRAMJET combustion characteristics as well as to increase the instrument's velocity dynamic range to span an intra-image range in excess of 2 km/s. The various technical efforts were brought together in a series of experiments demonstrating the applicability of the technique in a high pressure, high temperature H2-air combustion system. The resultant images were compared with 2-D flow simulations in order to determine the accuracy of the instrument. Mean velocity imaging in flows with an axis of symmetry was demonstrated with an accuracy of +/- 50 m/s out of an intra-image dynamic range of 1600 m/s, including reversed flow. A more complex configuration amenable to single-shot imaging in flows without an axis of symmetry was also demonstrated. Limitations imposed by available equipment resulted in an accuracy of about +/- 200 m/s out of 1750 m/s in these demonstrations. Minor modifications to the present configuration were suggested to improve this performance. Each technical task is described in detail, along with significance of the results for the overall imaging velocimeter configuration. This report should allow the user community to integrate this new measurement capability in their existing instrumentation platforms.

Allen, M. G.

Infrared radiative properties of rapidly cooling, initially molten Al2O3 particles

A shock tube technique was used to investigate the effects of rapid cooling of molten Al2O3 particles on their radiative signatures below the melt. Optically thin clouds of submicron Al2O3 particles in an Ar bath were shock-heated and then quench-cooled by a rarefaction wave. Visible pyrometry monitored the temperature history of the particles and infrared detectors quantified the IR signatures at several wavelengths. Data analysis gave values of the imaginary refractive index, k. As the particles cooled to submelt temperatures (1600 to 2300 K), the values of k remained near 0.1, comparable to the liquid values and several orders of magnitude larger than those for bulk alpha-Al2O3. This results in an enhancement of SWIR radiation by three or more orders of magnitude. These results give strong evidence that a rapid-cooling solidification process is primarily responsible for discrepancies between observed and predicted radiation in SRM tests.

Rawlins, W. T.

Exit plane H2O concentration measurements correlated with OH PLIF near-injector mixing measurements for scramjet flows

Mixing and combusting high enthalpy flows, similar to those encountered in scramjet engines, were investigated using a shock tunnel to produce the flow in conjunction with non-intrusive optical diagnostics which monitored the performance of two injector configurations. The shock tunnel is configured to produce Mach 3 flow and stagnation enthalpies corresponding to flight equivalent Mach numbers between 7 and 11. A pulsed hydrogen injection capability and interchangeable injector blocks provide a means of examining high speed, high enthalpy reacting flows. Planar laser induced fluorescence (PLIF) of OH molecules in the near injector region produced images which show the combusting and mixing zones for the reacting flow. Line-of-sight exit plane measurement of water concentration and temperature were used to provide a unique method of monitoring exit plane products. These results demonstrated that a velocity matched axial injection system produced a fuel jet that lifted off the floor of the duct. Mixing was observed to increase for this system as a velocity mismatch was introduced. Comparison of exit plane water concentrations for a wall jet injection system and a velocity matched injection system indicated similar mixing performance but an accurate pressure measurement is necessary to further validate the result. In addition, exit plane measurements indicated an approximate steady-state condition was achieved during the 1 to 2 ms test times.

Parker, T. E.

New results from optical polarimetry of Saturn's rings

Linear polarimetry of Saturn's rings, obtained through the period of the 1979 opposition, is presented. The polarisation clearly correlates in direction with the plane containing the Sun, planet and Earth, but not the ring plane. The results are consistent with local scattering on the surface of individual ring bodies, covered with frost

Johnson, P. E.

Analysis of aging data on SAW oscillators

Test oscillators including delay lines and resonators in the 300-400 MHz range have been investigated with reference to the long-term stability (aging) characteristics. All devices were fabricated on rotated Y-cut quartz plates (40 deg), and either gold or platinum metallization was used; all packages were high-quality hermetic enclosures, and the mounting was strictly mechanical, with no organics or silicone rubbers used. It is shown that drift of less than 2 ppm in the first year can be obtained on a significant fraction of the devices when reasonably clean packages are used. The data also suggest that the transducer metallization (at least for aluminum) is very likely the source of the relaxation mechanism that causes the frequency drift.

Parker, T. E.

Surface acoustic wave stabilized oscillators

Four areas of surface acoustic wave (SAW) controlled oscillators were investigated and a number of 401.2 MHz oscillators were constructed that showed improved performance. Aging studies on SAW devices packaged in HC36/U cold weld enclosures produced frequency drifts as low as 0.4 ppm in 35 weeks and drift rates well under 0.5 ppm/year. Temperature compensation circuits have substantially improved oscillator temperature stability, with a deviation of + or - 4 ppm observed over the range -45 C to + 40 C. High efficiency amplifiers were constructed for SAW oscillators and a dc to RF efficiency of 44 percent was obtained for an RF output of 25 mW. Shock and vibration tests were made on four oscillators and all survived 500 G shock pulses unchanged. Only when white noise vibration (20 Hz to 2000 Hz) levels of 20 G's rms were applied did some of the devices fail.

Parker, T. E.

Surface acoustic wave stabilized oscillators

A number of 401.2 MHz surface acoustic wave (SAW) controlled oscillators were built and tested. The performance of these oscillators was evaluated for possible use as stable oscillators in communication systems. A short term frequency stability of better than 1 x 10 to the minus 9th power for one second was measured for the SAW oscillators. Long term frequency drift was measured and was found to be dependent on SAW design and packaging. Drift rates ranging from 15 ppm in twenty weeks to 2.5 ppm in twenty weeks were observed. Some further improvement was required. The temperature dependence of the saw oscillators was evaluated and it was concluded that some form of temperature compensation will be necessary to meet the requirements of some communication systems.

Parker, T. E.

Current developments in SAW oscillator stability

The results reported were obtained with two port delay lines and resonators used in a simple feedback oscillator. The feedback oscillator employed inherently operates with the amplifier in a saturated condition and, therefore, the AM noise is suppressed. Consequently the dominant noise is FM. Generally, it can be concluded that for very narrow-band, or fixed-frequency applications, the resonator-type oscillator will give the best noise performance. For applications where tunability and linearity are important, the delay-line-type oscillator may give the best performance. There have been no significant improvements in oscillator temperature stability. The only two demonstrated materials for temperature stable SAW oscillators are ST-cut quartz and the SiO2/LiTaO3 overlay structure. Aging tests have been going on for the past two-and-a-half years and it has become obvious that the observed aging rates are largely related to cleaning and packaging.

Parker, T. E.