AEM Field Trial: Calculation and Calibration Algorithms
Abstract Not Provided
Engineering topics
Publications and source records attributed to Parker, Robert F.
Abstract Not Provided
The outline of this presentation is: (1) Technology basis of on-line enrichment monitoring; (2) Timescale of trial; (3) Description of installed equipment; (4) Photographs; (5) Results; (6) Possible further development; and (7) Conclusions. Summary of the good things about the Advanced Enrichment Monitor (AEM) performance is: (1) High accuracy - normally better than 1% relative, (2) Active system as accurate as passive system, (3) Fast and accurate detection of enrichment changes, (4) Physics is well understood, (5) Elegant method for capturing pressure signal, and (6) Data capture is automatic, low cost and fast. A couple of negative things are: (1) Some jumps in measured passive enrichment - of around +2% relative (due to clock errors?); and (2) Data handling and evaluation is off-line, expensive and very slow. Conclusions are: (1) LANL AEM is being tested on E23 plant at Capenhurst; (2) The trial is going very well; (3) AEM could detect production of HEU at potentially much lower cost than existing CEMO; (4) AEM can measure {sup 235}U assay accurately; (5) Active system using X-Ray source would avoid need for pressure measurement; (6) Substantial work lies ahead to go from current prototype to a production instrument.
Abstract Not Provided
The Dual Slab Verification Detector (DSVD) has been developed, built, and characterized by Los Alamos National Laboratory in cooperation with the International Atomic Energy Agency (IAEA) as part of the dry storage safeguards system for the spent fuel from the BN-350 fast reactor. The detector consists of two rows of 3He tubes embedded in a slab of polyethylene which has been designed to be placed on the outer surface of the dry storage cask. By performing DSVD measurements at several different locations around the outer surface of the DUC, a signature 'fingerprint' can be established for each DUC based on the neutron flux emanating from inside the dry storage cask. The neutron fingerprint for each individual DUC will be dependent upon the spatial distribution of nuclear material within the cask, thus making it sensitive to the removal of a certain amount of material from the cask. An initial set of DSVD measurements have been performed on the first set of dry storage casks that have been loaded with canisters of spent fuel and moved onto the dry storage pad to both establish an initial fingerprint for these casks as well as to quantify systematic uncertainties associated with these measurements. The results from these measurements will be presented and compared with the expected results that were determined based on MCNPX simulations of the dry storage facility. The ability to safeguard spent nuclear fuel is strongly dependent on the technical capabilities of establishing and maintaining continuity of knowledge (COK) of the spent fuel as it is released from the reactor core and either reprocessed or packaged and stored at a storage facility. While the maintenance of COK is often done using continuous containment and surveillance (C/S) on the spent fuel, it is important that the measurement capabilities exist to re-establish the COK in the event of a significant gap in the continuous CIS by performing measurements that independently confirm the presence and content of Plutonium (Pu) in the spent fuel. The types of non-destructive assay (NDA) measurements that can be performed on the spent fuel are strongly dependent on the type of spent fuel that is being safeguarded as well as the location in which the spent fuel is being stored. The BN-350 Spent Fuel Disposition Project was initiated to improve the safeguards and security of the spent nuclear fuel from the BN-350 fast-breeder reactor and was developed cooperatively to meet the requirements of the International Atomic Energy Agency (IAEA) as well as the terms of the 1993 CTR and MPC&A Implementing Agreements. The unique characteristics of fuel from the BN-350 fast-breeder reactor have allowed for the development of an integrated safeguards measurement program to inventory, monitor, and if necessary, re-verify Pu content of the spent fuel throughout the lifetime of the project. This approach includes the development of a safeguards measurement program to establish and maintain the COK on the spent fuel during the repackaging and eventual relocation of the spent-fuel assemblies to a long-term storage site. As part of the safeguards measurement program, the Pu content of every spent-fuel assembly from the BN-350 reactor was directly measured and characterized while the spent-fuel assemblies were being stored in the spent-fuel pond at the BN-350 facility using the Spent Fuel Coincidence Counter (SFCC). Upon completion of the initial inventory of the Pu content of the individual spent-fuel assemblies, the assemblies were repackaged into welded steel canisters that were filled with inert argon gas and held either four or six individual spent-fuel assemblies depending on the type of assembly that was being packaged. This repackaging of the spent-fuel assemblies was performed in order to improve the stability of the spent-fuel assemblies for long-term storage and increase the proliferation resistance of the spent fuel. To maintain the capability of verifying the presence of the spent-fuel assemblies inside the welded steel canisters, measurements were performed on the canisters using the Spent Fuel Attribute Monitor (SPAM), which was a neutron coincidence counter very similar in design to the SFCC, but with a larger operational volume to accommodate the canisters. The analysis of the neutron coincidence data from the measurements of the welded steel canisters using SP AM yielded a Canister Attribute (CA) that was shown to be proportional to the total amount of Pu mass that was present inside the canister and comparable to the CA values that were calculated based on the previous SFCC measurements. The next step in securing the spent fuel from the BN-350 reactor is the packaging of the steel canisters into Dual-Use Casks (DUCs) and the transportation of the DUCs to a remote dry storage site.
The Dual Slab Verification Detector (DSVD) has been developed and built by Los Alamos National Laboratory in cooperation with the International Atomic Energy Agency (IAEA) as part of the dry storage safeguards system for the spent fuel from the BN-350 fast reactor. The detector consists of two rows of {sup 3}He tubes embedded in a slab of polyethylene which has been designed to be placed on the outer surface of the dry storage cask. The DSVD will be used to perform measurements of the neutron flux emanating from inside the dry storage cask at several locations around each cask to establish a neutron 'fingerprint' that is sensitive to the contents of the cask. The sensitivity of the fingerprinting technique to the removal of specific amount of nuclear material from the cask is determined by the characteristics of the detector that is used to perform the measurements, the characteristics of the spent fuel being measured, and systematic uncertainties that are associated with the dry storage scenario. MCNPX calculations of the BN-350 dry storage asks and layout have shown that the neutron fingerprint verification technique using measurements from the DSVD would be sensitive to both the amount and location of material that is present within an individual cask. To confirm the performance of the neutron fingerprint technique in verifying the presence of BN-350 spent fuel in dry storage, an initial series of measurements have been performed to test the performance and characteristics of the DSVD. Results of these measurements will be presented and compared with MCNPX results.
The Unattended and Remote Monitoring (UNARM) system at the BN-350 fast breeder reactor facility in Aktau, Kazakhstan continues to provide safeguards monitoring data as the spent fuel disposition project transitions from wet fuel storage to dry storage casks. Qualitative data from the initial cask loading procedures has been released by the International Atomic Energy Agency (IAEA) and is presented here for the first time. The BN-350 fast breeder reactor in Aktau, Kazakhstan, operated as a plutonium-producing facility from 1973 W1til 1999. Kazakhstan signed the Nonproliferation Treaty (NPT) in February 1994, and shortly afterwards the IAEA began safeguarding the reactor facility and its nuclear material. Slnce the cessation of reactor operations ten years ago, the chief proliferation concern has been the spent fuel assemblies stored in the pond on-site. By 2002, all fuel assemblies in wet storage had been repackaged into proliferation-resistant canisters. From the beginning, the IAEA's safeguards campaign at the BN-350 included a constant unattended sensor presence in the form of UNARM which monitors nuclear material activities at the facility in the absence of inspector presence. The UNARM equipment at the BN-350 was designed to be modular and extensible, allowing the system to adapt as the safeguards requirements change. This has been particularly important at the BN-350 due to the prolonged wet storage phase of the project. The primary function of the BN-350 UNARM system is to provide the IAEA with an independent, radiation-centric Containment and Surveillance (C&S) layer in addition to the standard seals and video systems. The UNARM system has provided continuous Continuity of Knowledge (COK) data for the BN-350's nuclear material storage areas in order to ensure the validity of the attended measurements during the lifetime of the project. The first of these attended measurements was characterization of the spent fuel assemblies. This characterization utilized the Spent Fuel Coincidence Counter (SFCC) instrument [ref] to measure neutron multiplicity and calculate Pu mass. These calculated masses were then compared to modeling simulation of the assemblies as well as declarations from the facility in order to baseline the amount of material under IAEA safeguards [ref]. Once the baseline was established, bundles of four or six assemblies were repackaged into proliferati n-resistant canisters. This provided an additional physical barrier to material diversion and provided further protection by choosing assemblies for each canister so that the overall dose rate met self-protection requirements. Each of the canisters were then characterized using a similar technique to the SFCC, but with the Spent Fuel Attribute Monitor (SPAM) instnunent (ref). The data from these measurements were then used to calculate an attribute proportional to the total Pu mass in each canister. This attribute was then compared to the know Pu mass of each assembly in order to verify the accuracy of SPAM. In the event that COK is lost, the SPAM detector remains positioned to reverify Pu content of individual canisters without requiring the canister to be opened.