Quantitative Fit Evaluation of N95 Filtering Facepiece Respirators and Coronavirus Inactivation Following Heat Treatment

Abstract Reuse of filtering facepiece respirators (FFRs, commonly referred to as N95s) normally meant for single use has become common in healthcare facilities due to shortages caused by the COVID-19 pandemic. Here, we report that murine hepatitis coronavirus initially seeded on FFR filter material is inactivated (6 order of magnitude reduction as measured by median tissue culture infective dose, TCID50) after dry heating at 75°C for 30 min. We also find that the quantitative fit of FFRs after heat treatment at this temperature, under dry conditions or at 90% relative humidity, is not affected by single or 10 heating cycles. Previous studies have reported that the filtration efficiency of FFRs is not negatively impacted by these heating conditions. These results suggest that thermal inactivation of coronaviruses is a potentially rapid and widely deployable method to reuse N95 FFRs in emergency situations where reusing FFRs is a necessity and broad-spectrum sterilization is unavailable. However, we also observe that a radiative heat source (e.g. an exposed heating element) results in rapid qualitative degradation of the FFR. Finally, we discuss differences in the results reported here and other recent studies investigating heat as a means to recycle FFRs. These differences suggest that while our repeated decontamination cycles do not affect FFR fit, overall wear time and the number of donning/doffing cycles are important factors that likely degrade FFR fit and must be investigated further.

60 APPLIED LIFE SCIENCES↗

Quantitative Validation of Control Bands Using Bayesian Statistical Analyses

Abstract This study presents a quantitative validation of 15 Similar Exposure Groups (SEGs) that were derived via control bands inherent to the Risk Level Based Management System currently being used at the Lawrence Livermore National Laboratory. For 93% of the SEGs that were evaluated, statistical analyses of personal exposure monitoring data, through Bayesian Decision Analysis (BDA), demonstrated that the controls implemented from the initial control bands assigned to these SEGs were at least as protective as the controls from the control band outcomes derived from the quantitative data. The BDA also demonstrated that for 40% of the SEGs, the controls from the initial control bands were overly protective, thus allowing controls to be downgraded, which resulted in a significant saving of environmental safety and health (ES&H) resources. Therefore, as a means to both confirm existing controls and to identify candidate SEGs for downgrading controls, efforts to continuously improve the accuracy of Control Banding (CB) strategies through the routine quantitative validation of SEGs are strongly encouraged. Targeted collaborative efforts across institutions and even countries for both the development of CB strategies and the validation of discreetly defined SEGs of commonly performed tasks will not only optimize limited ES&H resources but will also assist in providing a simplified process for essential risk communication at the worker level to the benefit of billions of workers around the world.

McCord, Tyler A.↗

A Quantitative Validation of the Control Banding Nanotool

Abstract Eleven years (by publication) years after the development and application of the control banding (CB) Nanotool for the qualitative assessment and control of engineered nanoparticles (ENP), there remains no quantitative gold standard to serve as an alternative to the qualitative assessment. Many CB models have been developed during the years subsequent to the initial development of the CB Nanotool and the literature continues to blossom with comparisons and applications of these various tools; however, these developments have hitherto been made in the absence of validating and verifying their effectiveness using existing, albeit limited, quantitative methods. This paper reviews the existing literature on the CB Nanotool to evaluate its effectiveness in a variety of settings and presents a summary of qualitative and quantitative information from its application in a broad range of ENP handling activities performed in two different research institutions. A total of 28 ENP activities were assessed using the CB Nanotool (Version 2.0). Due to the lack of guidance on a single exposure assessment methodology, a combination of real-time monitoring, filter analysis, and microscopic analysis was used to assess various quantitative metrics, including mass concentration, particle number concentration, and particle speciation. All the results indicated that the control outcomes from the CB Nanotool qualitative assessment were sufficient to prevent workers from being exposed to ENP at levels beyond established exposure limits or background levels. These data represent an independent quantitative validation of CB Nanotool risk level outcomes and give further credence to the use of the CB Nanotool to effectively control worker exposures in the absence of quantitative air monitoring results.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Assessment of personal airborne exposures and surface contamination from x-ray vaporization of beryllium targets at the National Ignition Facility

Here, this article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measures in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2 , for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. Finally, all the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Association between Electronic Cigarette Use and Asthma among High School Students in South Korea

Little is known about health outcomes related to electronic cigarette (EC) use, despite its growing popularity. The aim of this study is to investigate the association between EC use and asthma. The study design is a cross-sectional study. A total of 35,904 high school students were included as the final study population. The presence of asthma was based on a student’s self-reported doctor diagnosis of asthma in the past 12 months. Results showed prevalence rates of asthmatics in ‘current EC users’ (n = 2,513), ‘former EC users’ (n = 2,078), and ‘never EC users’ (n = 31,313), were 3.9% (n = 98), 2.2% (n = 46) and 1.7% (n = 530), respectively. Comparing ‘current EC’ users with ‘never EC’ users, the unadjusted OR for asthma was 2.36 (95% CI: 1.89–2.94). In order to control for the effect of conventional cigarette (CC) smoking, after stratifying the subjects by the three CC smoking categories (never CC, former CC, and current CC), within the ‘never CC’ category, the unadjusted OR for asthma for ‘current EC’ users was 3.41 (95% CI: 1.79–6.49), and the adjusted OR was 2.74 (95% CI: 1.30–5.78). Severe asthma was reflected by the number of days absent from school due to asthma symptoms; current EC users had the highest adjusted OR for severe asthma compared to ‘never EC’ users. In conclusion, when compared to a reference population of high school students in South Korea, EC users have an increased association with asthma and are more likely to have had days absent from school due to severe asthma symptoms. In conclusion, the results indicate that EC use may be a risk factor for asthma. The results may be useful in developing a scientific basis for the evaluation of a potential health hazard by EC.

60 APPLIED LIFE SCIENCES↗