Engineering Papers⌕ Search

Engineering topics

Pagnanini, L.

Publications and source records attributed to Pagnanini, L..

At least 19 records

Searching for beyond the Standard Model physics using the improved description of 100 Mo $2\nu \beta \beta$ decay spectral shape with CUPID-Mo

The current experiments searching for neutrinoless double-β ($0\nu \beta \beta$) decay also collect large statistics of Standard Model allowed two-neutrino double-β ($2\nu \beta \beta$ ) decay events. These can be used to search for Beyond Standard Model (BSM) physics via $2\nu \beta \beta$ decay spectral distortions. 100 Mo has a natural advantage due to its relatively short half-life, allowing higher $2\nu \beta \beta$ decay statistics at equal exposures compared to the other isotopes. We demonstrate the potential of the dual read-out bolometric technique exploiting a 100 Mo exposure of 1.47 kg years, acquired in the CUPID-Mo experiment at the Modane underground laboratory (France). We set limits on $0\nu \beta \beta$ decays with the emission of one or more Majorons, on $2\nu \beta \beta$ decay with Lorentz violation, and $2\nu \beta \beta$ decay with a sterile neutrino emission. In this analysis, we investigate the systematic uncertainty induced by modeling the $2\nu \beta \beta$ decay spectral shape parameterized through an improved model, an effect never considered before. This work motivates searches for BSM processes in the upcoming CUPID experiment, which will collect the largest amount of $2\nu \beta \beta$ decay events among the next-generation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data-driven background model for the CUORE experiment

Here, we present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth exploration of both spatial and time dependence of backgrounds. We achieve high sensitivity to both bulk and surface activities of the materials of the setup, detecting levels as low as 10 nBq kg −1 and 0.1 nBq cm −2 , respectively. We compare the contamination levels we extract from the background model with prior radio-assay data, which informs future background risk mitigation strategies. The results of this background model play a crucial role in constructing the background budget for the CUPID experiment as it will exploit the same CUORE infrastructure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the 2 ν β β Decay Rate and Spectral Shape of Mo 100 from the CUPID-Mo Experiment

Neutrinoless double beta decay (0νββ) is a yet unobserved nuclear process that would demonstrate Lepton number violation, a clear evidence of beyond standard model physics. The process two neutrino double beta decay (2νββ) is allowed by the standard model and has been measured in numerous experiments. In this Letter, we report a measurement of 2νββ decay half-life of 100 Mo to the ground state of 100 Ru of [7.07±0.02(stat)±0.11(syst)]×10 18 yr by the CUPID-Mo experiment. With a relative precision of ±1.6% this is the most precise measurement to date of a 2νββ decay rate in 100 Mo. In addition, we constrain higher-order corrections to the spectral shape, which provides complementary nuclear structure information. We report a novel measurement of the shape factor ξ 3,1 =0.45±0.03(stat)±0.05(syst) based on a constraint on the ratio of higher-order terms from theory, which can be reliably calculated. This is compared to theoretical predictions for different nuclear models. Finally, we also extract the first value for the effective axial vector coupling constant obtained from a spectral shape study of 2νββ decay.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The background model of the CUPID-Mo $0\nu\beta\beta$ experiment

CUPID-Mo, located in the Laboratoire Souterrain de Modane (France), was a demonstrator for the next generation 0vββ decay experiment, CUPID. It consisted of an array of 20 enriched Li 2 100 MoO 4 bolometers and 20 Ge light detectors and has demonstrated that the technology of scintillating bolometers with particle identification capabilities is mature. Furthermore, CUPID-Mo can inform and validate the background prediction for CUPID. In this paper, we present a detailed model of the CUPID-Mo backgrounds. This model is able to describe well the features of the experimental data and enables studies of the 2vββ decay and other processes with high precision. We also measure the radio-purity of the Li 2 100 MoO 4 crystals which are found to be sufficient for the CUPID goals. Finally, we also obtain a background index in the region of interest of 3.7 $^{+0.9}_{-0.8}$ (stat) $^{+1.5}_{-0.7}$ (syst) x 10 -3 counts/ ΔE FWHM / mol iso / year the lowest in a bolometric Ovββ decay experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New measurement of double- β decays of Mo 100 to excited states of Ru 100 with the CUPID-Mo experiment

The CUPID-Mo experiment, located at Laboratoire Souterrain de Modane (France), was a demonstrator experiment for CUPID. It consisted of an array of 20 Li 2 100 MoO 4 (LMO) calorimeters each equipped with a Ge light detector (LD) for particle identification. In this work, we present the result of a search for two-neutrino and neutrinoless double beta decays of 100 Mo to the first 0 + and 2 + excited states of 100 Ru using the full CUPID-Mo exposure (2.71 kg yr of LMO). We measure the half-life of 2νββ decay to the $0^+_1$ state as $T^{2ν→0^+_1}_{1/2}$ = (7.5 ± 0.8 (stat.) $^{+0.4}_{-0.3}$ (syst.)) × 10 20 yr. The bolometric technique enables measurement of the electron energies as well as the gamma rays from nuclear de-excitation and this allows us to set new limits on the two-neutrino decay to the $2^+_1$ state of $T^{2ν→2^+_1}_{1/2}$ > 4.4×10 21 yr (90% c.i.) and on the neutrinoless modes of $T^{0ν→2^+_1}_{1/2}$ > 2.1×10 23 yr (90% c.i.), $T^{0ν→0^+_1}_{1/2}$ > 1.2 × 10 23 yr (90% c.i.). Information on the electrons spectral shape is obtained which allows us to make the first comparison of the single state (SSD) and higher state (HSD) 2νββ decay models for the $0^+_1$ excited state of 100 Ru.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Disentangling the sources of ionizing radiation in superconducting qubits

Abstract Radioactivity was recently discovered as a source of decoherence and correlated errors for the real-world implementation of superconducting quantum processors. In this work, we measure levels of radioactivity present in a typical laboratory environment (from muons, neutrons, and $$\gamma $$ γ -rays emitted by naturally occurring radioactive isotopes) and in the most commonly used materials for the assembly and operation of state-of-the-art superconducting qubits. We present a GEANT-4 based simulation to predict the rate of impacts and the amount of energy released in a qubit chip from each of the mentioned sources. We finally propose mitigation strategies for the operation of next-generation qubits in a radio-pure environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of ultralow-background cryogenic calorimeters for the measurement of surface α contamination

Next-generation experiments searching for rare events must satisfy increasingly stringent requirements on the bulk and surface radioactive contamination of their active and structural materials. The measurement of surface contamination is particularly challenging, as no existing technology is capable of separately measuring parts of the 232 Th and 238 U decay chains that are commonly found to be out of secular equilibrium. We will present the results obtained with a detector prototype consisting of 8 silicon wafers of 150mm diameter instrumented as bolometers and operated in a low-background dilution refrigerator at the Gran Sasso Underground Laboratory of INFN, Italy. Furthermore, the prototype was characterized by a baseline energy resolution of few keV and a background <100nBq/cm 2 in the full range of α energies, obtained with simple procedures for cleaning of all employed materials and no specific measures to prevent recontamination. Such performance, together with the modularity of the detector design, demonstrate the possibility to realize an alpha detector capable of separately measuring all alpha emitters of the 232 Th and 238 U chains, possibly reaching a sensitivity of few nBq/cm 2 .

07 ISOTOPE AND RADIATION SOURCES↗

New Direct Limit on Neutrinoless Double Beta Decay Half-Life of 128 $\mathrm{Te}$ with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) at Laboratori Nazionali del Gran Sasso of INFN in Italy is an experiment searching for neutrinoless double beta (0νββ) decay. Its main goal is to investigate this decay in 130 Te, but its ton-scale mass and low background make CUORE sensitive to other rare processes as well. Here, in this Letter, we present our first results on the search for 0νββ decay of 128 Te, the Te isotope with the second highest natural isotopic abundance. We find no evidence for this decay, and using a Bayesian analysis we set a lower limit on the 128 Te 0νββ decay half-life of T 1/2 > 3.6 x 10 24 yr (90% CI). This represents the most stringent limit on the half-life of this isotope, improving by over a factor of 30 the previous direct search results, and exceeding those from geochemical experiments for the first time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. CUORE uses a cryogenic array of 988 TeO 2 calorimeters operated at ~10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. Further, we demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy-dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

47 OTHER INSTRUMENTATION↗

Final results on the $$0\nu \beta \beta $$ decay half-life limit of $$^{100}$$Mo from the CUPID-Mo experiment

Abstract The CUPID-Mo experiment to search for 0 $$\nu \beta \beta $$ ν β β decay in $$^{100}$$ 100 Mo has been recently completed after about 1.5 years of operation at Laboratoire Souterrain de Modane (France). It served as a demonstrator for CUPID, a next generation 0 $$\nu \beta \beta $$ ν β β decay experiment. CUPID-Mo was comprised of 20 enriched $$\hbox {Li}_{{2}}$$ Li 2 $$^{100}$$ 100 $$\hbox {MoO}_4$$ MoO 4 scintillating calorimeters, each with a mass of $$\sim 0.2$$ ∼ 0.2 kg, operated at $$\sim 20$$ ∼ 20 mK. We present here the final analysis with the full exposure of CUPID-Mo ( $$^{100}$$ 100 Mo exposure of 1.47 $$\hbox {kg} \times \hbox {year}$$ kg × year ) used to search for lepton number violation via 0 $$\nu \beta \beta $$ ν β β decay. We report on various analysis improvements since the previous result on a subset of data, reprocessing all data with these new techniques. We observe zero events in the region of interest and set a new limit on the $$^{100}$$ 100 Mo 0 $$\nu \beta \beta $$ ν β β decay half-life of $$T_{1/2}^{0\nu }$$ T 1 / 2 0 ν $$> {1.8}\times 10^{24}$$ > 1.8 × 10 24 year (stat. + syst.) at 90% CI. Under the light Majorana neutrino exchange mechanism this corresponds to an effective Majorana neutrino mass of $$\left $$ m β β $$<~{(0.28{-}0.49)} $$ < ( 0.28 - 0.49 ) eV, dependent upon the nuclear matrix element utilized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Latest Results from the CUORE Experiment

Abstract The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for $$0\nu \beta \beta $$ 0 ν β β decay that has been able to reach the one-tonne mass scale. The detector, located at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, consists of an array of 988 $${\mathrm{TeO}}_{2}$$ TeO 2 crystals arranged in a compact cylindrical structure of 19 towers. CUORE began its first physics data run in 2017 at a base temperature of about 10 mK and in April 2021 released its $$3{\mathrm{rd}}$$ 3 rd result of the search for $$0\nu \beta \beta $$ 0 ν β β , corresponding to a tonne-year of $$\mathrm{TeO}_{2}$$ TeO 2 exposure. This is the largest amount of data ever acquired with a solid state detector and the most sensitive measurement of $$0\nu \beta \beta $$ 0 ν β β decay in $${}^{130}\mathrm{Te}$$ 130 Te ever conducted . We present the current status of CUORE search for $$0\nu \beta \beta $$ 0 ν β β with the updated statistics of one tonne-yr. We finally give an update of the CUORE background model and the measurement of the $${}^{130}\mathrm{Te}$$ 130 Te $$2\nu \beta \beta $$ 2 ν β β decay half-life and decay to excited states of $${}^{130}\mathrm{Xe}$$ 130 Xe , studies performed using an exposure of 300.7 kg yr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for neutrinoless β-plus-EC decay of 120 Te with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale cryogenic experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than 130 Te. In this work we describe a search for neutrinoless positron-emitting electron capture (β + EC ) decay in 120 Te with a total TeO 2 exposure of 355.7 kg yr, corresponding to 0.2405 kg yr of 120 Te. Albeit 0νββ with two final-state electrons represents the most promising channel, the emission of a positron and two 511-keV γ 's make 0νβ + EC decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of 3.4 × 10 22 yr at 90% credibility interval (C.I.). After unblinding we find no evidence of 0νβ + EC signal and set a 90% C.I. Bayesian lower limit of 2.9 × 10 22 yr on 120 Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter–antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta (0νββ) decay. Here we show results from the search for 0νββ decay of 130 Te, using the latest advanced cryogenic calorimeters with the CUORE experiment3. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultralow temperatures, operational longevity, and the low levels of ionizing radiation emanating from the cryogenic infrastructure. We find no evidence for 0νββ decay and set a lower bound of the process half-life as 2.2 × 10 25 years at a 90 percent credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultralow-temperature cryogenic environment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New results from the CUORE experiment

We report that the Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrino-less double-beta (0vββ) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO 2 crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its second result of the search for 0vββ corresponding to a TeO 2 exposure of 372.5 kg∙yr and a median exclusion sensitivity to a 130 Te 0vββ decay half-life of 1.7 ∙ 10 25 yr. We find no evidence for 0vββ decay and set a 90% C.I. Bayesian lower limit of 3.2 ∙ 10 25 yr on the 130 Te 0vββ decay half-life. We present the current status of CUORE’s search for 0vββ. We give an update of the CUORE background model and the measurement of the 130 Te two neutrino double-beta (2vββ) decay half-life. Eventually, we show the preliminary results on half-life limits from the analysis of 130 Te 0vββ and 2vββ decay to the first 0 + excited state of 130 Xe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Background identification in cryogenic calorimeters through $\alpha -\alpha$ delayed coincidences

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $\alpha -\alpha$ delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $\alpha$ decay position.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for double-beta decay of $$\mathrm {^{130}Te}$$ to the $$0^+$$ states of $$\mathrm {^{130}Xe}$$ with CUORE

Abstract The CUORE experiment is a large bolometric array searching for the lepton number violating neutrino-less double beta decay ( $$0\nu \beta \beta $$ 0 ν β β ) in the isotope $$\mathrm {^{130}Te}$$ 130 Te . In this work we present the latest results on two searches for the double beta decay (DBD) of $$\mathrm {^{130}Te}$$ 130 Te to the first $$0^{+}_2$$ 0 2 + excited state of $$\mathrm {^{130}Xe}$$ 130 Xe : the $$0\nu \beta \beta $$ 0 ν β β decay and the Standard Model-allowed two-neutrinos double beta decay ( $$2\nu \beta \beta $$ 2 ν β β ). Both searches are based on a 372.5 kg $$\times $$ × yr TeO $$_2$$ 2 exposure. The de-excitation gamma rays emitted by the excited Xe nucleus in the final state yield a unique signature, which can be searched for with low background by studying coincident events in two or more bolometers. The closely packed arrangement of the CUORE crystals constitutes a significant advantage in this regard. The median limit setting sensitivities at 90% Credible Interval (C.I.) of the given searches were estimated as $$\mathrm {S^{0\nu }_{1/2} = 5.6 \times 10^{24} \, \mathrm {yr}}$$ S 1 / 2 0 ν = 5.6 × 10 24 yr for the $${0\nu \beta \beta }$$ 0 ν β β decay and $$\mathrm {S^{2\nu }_{1/2} = 2.1 \times 10^{24} \, \mathrm {yr}}$$ S 1 / 2 2 ν = 2.1 × 10 24 yr for the $${2\nu \beta \beta }$$ 2 ν β β decay. No significant evidence for either of the decay modes was observed and a Bayesian lower bound at $$90\%$$ 90 % C.I. on the decay half lives is obtained as: $$\mathrm {(T_{1/2})^{0\nu }_{0^+_2} > 5.9 \times 10^{24} \, \mathrm {yr}}$$ ( T 1 / 2 ) 0 2 + 0 ν > 5.9 × 10 24 yr for the $$0\nu \beta \beta $$ 0 ν β β mode and $$\mathrm {(T_{1/2})^{2\nu }_{0^+_2} > 1.3 \times 10^{24} \, \mathrm {yr}}$$ ( T 1 / 2 ) 0 2 + 2 ν > 1.3 × 10 24 yr for the $$2\nu \beta \beta $$ 2 ν β β mode. These represent the most stringent limits on the DBD of $$^{130}$$ 130 Te to excited states and improve by a factor $$\sim 5$$ ∼ 5 the previous results on this process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Limit for Neutrinoless Double-Beta Decay of 100 Mo from the CUPID-Mo Experiment

The CUPID-Mo experiment at the Laboratoire Souterrain de Modane (France) is a demonstrator for CUPID, the next-generation ton-scale cryogenic $0\nu\beta\beta$ experiment. It consists of a 4.2 kg array of 20 enriched Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers to search for the lepton number violating process of $0\nu\beta\beta$ decay in $^{100}$Mo. With more than one year of operation (2.16 kg$\times$yr of physics data), no event in the region of interest and hence no evidence for $0\nu\beta\beta$ is observed. We report a new limit on the half-life of $0\nu\beta\beta$ decay in $^{100}$Mo of $T_{1/2} > 1.5 \times 10^{24}\,$yr at 90 % C.I. The limit corresponds to an effective Majorana neutrino mass $\langle m_{\beta\beta} \rangle$ $<$ (0.3--0.5)$\,$eV, dependent on the nuclear matrix element in the light Majorana neutrino exchange interpretation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗