Engineering Papers⌕ Search

Engineering topics

Pagani, L.

Publications and source records attributed to Pagani, L..

At least 19 records

Ultra-pure nickel for structural components of low-radioactivity instruments

The next generation of nuclear and particle physics rare-event search experiments demand structural materials combining ultra-low levels of radioactive contamination with exceptional mechanical strength. Here, this study evaluates chemical vapor deposition (CVD) nickel as a low radioactive background candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates was assayed via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution. These material assays produced measured bulk concentration of 232 Th, 238 U, and nat K at the levels of ~70 ppq, ≲100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 μ m beneath the surface, likely associated with the aluminum growth substrate. Additionally, the CVD Ni underwent tensile testing alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, heat treatment was found to reduce the tensile strength to levels comparable to standard Ni, with implications for high-temperature weld joining methods. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in surface cleaning and weld-joining techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

47 OTHER INSTRUMENTATION↗

Supernova electron-neutrino interactions with xenon in the nEXO detector

Electron-neutrino charged-current interactions with xenon nuclei were modeled in the nEXO neutrinoless double-𝛽 decay detector (∼5 metric ton, 90% 136 Xe, 10% 134 Xe) to evaluate its sensitivity to supernova neutrinos. Predictions for event rates and detectable signatures were modeled using the Model of Argon Reaction Low Energy Yields (MARLEY) event generator. We find good agreement between MARLEY’s predictions and existing theoretical calculations of the inclusive cross sections at supernova neutrino energies. The interactions modeled by MARLEY were simulated within the nEXO simulation framework and were run through an example reconstruction algorithm to determine the detector’s efficiency for reconstructing these events. The simulated data, incorporating the detector response, were used to study the ability of nEXO to reconstruct the incident electron-neutrino spectrum and these results were extended to a larger xenon detector of the same isotope enrichment. We estimate that nEXO will be able to observe electron-neutrino interactions with xenon from supernovae as far as 5–8 kpc from Earth, while the ability to reconstruct incident electron-neutrino spectrum parameters from observed interactions in nEXO is limited to closer supernovae.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overcoming photobleaching in imaging of single barium atoms in a solid xenon matrix

Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is 136 Xe, which would double beta decay into 136 Ba. Detecting the single 136 Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for dark matter annual modulation with DarkSide-50

Dark matter may induce an event in an Earth-based detector, and its event rate is predicted to show an annual modulation as a result of the Earth’s orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above 40 eV ee , the lowest threshold ever achieved in such a search. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-term temporal stability of the DarkSide-50 dark matter detector

The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. Here, in this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for low mass dark matter in DarkSide-50: the bayesian network approach

Abstract We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of the scintillation time response of liquid argon detectors for dark matter search

The scintillation time response of liquid argon has a key role in the discrimination of electronic backgrounds in dark matter search experiments. However, its extraordinary rejection power can be affected by various detector effects such as the delayed light emission of TetraPhenyl Butadiene, the most commonly used wavelength shifter, and the electric drift field applied in Time Projection Chambers. Herein, we characterized the TetraPhenyl Butadiene delayed response and the dependence of the pulse shape discrimination on the electric field, exploiting the data acquired with the ARIS, a small-scale single-phase liquid argon detector exposed to monochromatic neutron and gamma sources at the ALTO facility of IJC Lab in Orsay.

47 OTHER INSTRUMENTATION↗

Measurement of the neutron capture cross section on argon

The use of argon as a detection and shielding medium for neutrino and dark matter experiments has made a precise knowledge of the cross section for neutron capture on argon an important design and operational parameter. While previous measurements were averaged over thermal spectra and have significant disagreements, a differential measurement has been performed using a Time-Of-Flight neutron beam and a ~4π gamma spectrometer. Here, a fit to the differential cross section from 0.015-0.15 eV, assuming a 1/v energy dependence, yields σ 2200 = 673 ± 26 (stat.) ± 59 (sys.) mb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute calibration of the DANCE thermal neutron beam using sodium activation

The calculation of the neutron capture cross section as a function of energy in the thermal range requires a precise knowledge of the absolute neutron flux. In this paper a method of calibrating a thermal neutron beam using the controlled activation of sodium is described. Here, the method is applied to the FP-14 Time Of Flight neutron beam line at the Los Alamos Neutron Science Center to calibrate the beam to an uncertainty level of ±5 %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of argon response and light detection in the DarkSide-50 dual phase TPC

A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10 7 , using the pulse shape discrimination technique, and the measurement of the residual 39 Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the detector response to the liquid argon scintillation, its ionization, and electron-ion recombination processes. This work provides a complete overview of the DarkSide Monte Carlo and of its performance, with a particular focus on PARIS, the custom-made liquid argon response model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DarkSide-50 Experiment: a Liquid Argon Target for Dark Matter Particles

The DarkSide-50 experiment, located at the “Laboratori Nazionali del Gran Sasso (INFN)”, is based on low-radioactivity argon double phase time projection chamber, surrounded by an active liquid scintillator veto, designed for the zero background achievement. The liquid argon features sufficient self shielding and easy scalability to multi-tons scale. The impressive reduction of the 39 Ar isotope (compared to the atmospheric argon), along with the excellent pulse shape discrimination, make this technology a possible candidate for the forthcoming generation of multi-ton Dark Matter experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

The electronics and data acquisition system for the DarkSide-50 veto detectors

DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors. The system is made of a custom built front end electronics and commercial National Instruments high speed digitizers. The front end electronics, the DAQ, and the trigger system have been used to acquire data in the form of zero-suppressed waveform samples from the 110 PMTs of the LSV and the 80 PMTs of the WCV. The veto DAQ system has proven its performance and reliability. This electronics and DAQ system can be scaled and used as it is for the veto of the next generation DarkSide-20k detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ANALYSIS OF THE HERSCHEL /HEXOS SPECTRAL SURVEY TOWARD ORION SOUTH: A MASSIVE PROTOSTELLAR ENVELOPE WITH STRONG EXTERNAL IRRADIATION

We present results from a comprehensive submillimeter spectral survey toward the source Orion South, based on data obtained with the Heterodyne Instrument for the Far-Infrared instrument on board the Herschel Space Observatory , covering the frequency range of 480 to 1900 GHz. We detect 685 spectral lines with signal-to-noise ratios (S/Ns) > 3 σ , originating from 52 different molecular and atomic species. We model each of the detected species assuming conditions of Local Thermodynamic Equilibrium. This analysis provides an estimate of the physical conditions of Orion South (column density, temperature, source size, and V {sub LSR}). We find evidence for three different cloud components: a cool ( T {sub ex} ∼ 20–40 K), spatially extended (>60″), and quiescent (Δ V {sub FWHM} ∼ 4 km s{sup -1}) component; a warmer ( T {sub ex} ∼ 80–100 K), less spatially extended (∼30″), and dynamic (Δ V {sub FWHM} ∼ 8 km s{sup -1}) component, which is likely affected by embedded outflows; and a kinematically distinct region ( T {sub ex} > 100 K; V {sub LSR} ∼ 8 km s{sup -1}), dominated by emission from species that trace ultraviolet irradiation, likely at the surface of the cloud. We find little evidence for the existence of a chemically distinct “hot-core” component, likely due to the small filling factor of the hot core or hot cores within the Herschel beam. We find that the chemical composition of the gas in the cooler, quiescent component of Orion South more closely resembles that of the quiescent ridge in Orion-KL. The gas in the warmer, dynamic component, however, more closely resembles that of the Compact Ridge and Plateau regions of Orion-KL, suggesting that higher temperatures and shocks also have an influence on the overall chemistry of Orion South.

79 ASTRONOMY AND ASTROPHYSICS↗

STAR FORMATION AND FEEDBACK: A MOLECULAR OUTFLOW–PRESTELLAR CORE INTERACTION IN L1689N

We present Herschel ,{sup 11} ALMA Compact Array (ACA), and Caltech Submillimeter Observatory observations of the prestellar core in L1689N, which has been suggested to be interacting with a molecular outflow driven by the nearby solar-type protostar IRAS 16293-2422. This source is characterized by some of the highest deuteration levels observed in the interstellar medium. The change in the NH{sub 2}D line velocity and width across the core provides clear evidence of an interaction with the outflow, traced by the high-velocity water emission. Quiescent, cold gas characterized by narrow line widths is seen in the NE part of the core, while broader, more disturbed line profiles are seen in the W/SW part. Strong N{sub 2}D{sup +} and ND{sub 3} emission is detected with ACA extending S/SW from the peak of the single-dish NH{sub 2}D emission. The ACA data also reveal the presence a compact dust continuum source with a mean size of ∼1100 au, a central density of (1–2) × 10{sup 7} cm{sup −3}, and a mass of 0.2–0.4 M {sub ⊙}. The dust emission peak is displaced ∼5″ to the south with respect to the N{sub 2}D{sup +} and ND{sub 3} emission, as well as the single-dish dust continuum peak, suggesting that the northern, quiescent part of the core is characterized by spatially extended continuum emission, which is resolved out by the interferometer. We see no clear evidence of fragmentation in this quiescent part of the core, which could lead to a second generation of star formation, although a weak dust continuum source is detected in this region in the ACA data.

79 ASTRONOMY AND ASTROPHYSICS↗

The DarkSide awakens

Here, the DarkSide program at LNGS aims to perform background-free WIMP searches using two phase liquid argon time projection chambers, with the ultimate goal of covering all parameters down to the so-called neutrino floor. One of the distinct features of the program is the use of underground argon with has a reduced content of the radioactive 39 Ar compared to atmospheric argon. The DarkSide Collaboration is currently operating the DarkSide-50 experiment, the first such WIMP detector using underground argon. Operations with underground argon indicate a suppression of 39 Ar by a factor (1.4 ± 0.2) × 10 3 relative to atmospheric argon. The new results obtained with DarkSide-50 and the plans for the next steps of the DarkSide program, the 20t fiducial mass DarkSide-20k detector and the 200 t fiducial Argo, are reviewed in this proceedings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗