Engineering PapersSearch

Engineering topics

Paas, J. E.

Publications and source records attributed to Paas, J. E..

CF6-6D engine short-term performance deterioration

Studies conducted as part of the NASA-Lewis CF6 jet engine diagnostics program are summarized. An 82-engine sample of DC-10-10 aircraft engine checkout data that were gathered to define the extent and magnitude of CF6-6D short term performance deterioration were analyzed. These data are substantiated by the performance testing and analytical teardown of CF6-6D short term deterioration engine serial number (ESN) 451507.

Kramer, W. H.

CF6 jet engine performance deterioration results

The use of the performance baseline from the flight planning manual as a reference to measure changes in cruise fuel flow rates was discussed. For the CF6-6D engine, the introduction of design changes for performance and durability reasons was seen to introduce an average increment relative to this baseline of 3.2% WFM increase at Nl, 2.5% Fn increase at Nl, 0.8% specific fuel consumption (SFC) increase at Fn, and 7 C EGT increase at Nl, while maintaining sufficient SFC margin of the delivered airplane. The effect of revenue service deterioration and performance restoration relative to the reference was shown to be an adder on top of these design effects. A schematic of typical CF6-6D performance through revenue service and airline maintenance is presented in terms of percent cruise SFC relative to an airline datum point (average level upon entering revenue service). The typical changes in SFC margin are shown for airline revenue service through for installations and refurbishments.

Lewis, R. J.

Analytical and experimental studies of acoustic performance of segmented liners in a compressor inlet

The performance of axially segmented (phased) acoustic treatment liners in the inlet of a compressor was investigated. Topics discussed include: (1) the validation of a theoretical procedure to predict propagation and suppression characteristics of duct liners; (2) the in-duct measurement of spinning modes; (3) investigation of phased treatment designs; (4) high Mach inlet acoustic tests; and (5) an experimental investigation of inlet turbulence. The analytical prediction for the multi-segmented treatment was found to provide the correct order of magnitude of suppression and was generally within 50% of that determined experimentally. Refinements required to improve the correlation are identified. Suppression due to high subsonic Mach number flow effects was found to become significant above an average throat Mach number of 0.65 to 0.7 and 20 PNdB was achieved with an average throat Mach number in the range of 0.80 to 0.85. For the measured turbulence in the inlet, including the axial and circumferential turbulence intensities and the axial integral length scale, data are presented with and without an inlet screen showing that the screen reduced the turbulence intensities and that the BPF noise was reduced as a consequence.

Motsinger, R. E.

Effects of multi-element acoustic treatment on compressor inlet noise

An analytic and experimental study was conducted with the objective of developing both a basic understanding of axially segmented inlet acoustic treatment liners, and design procedures for enhancing the suppression of compressor inlet radiated noise. Anechoic chamber measurements demonstrated that the multielement treatment produced significantly more low frequency suppression than uniform treatment. Further, in-duct spinning mode patterns generated by the rotating vehicle were successfully measured and used as input to an analytical prediction procedure, providing significant improvement in inlet suppression predictions. The study indicated that phased inlet liners can be designed to provide increased noise suppression compared to uniform treatment.

Kraft, R. E.

Acoustic testing of a 1.5 pressure ratio low tip speed fan with a serrated rotor (QEP fan B scale model)

A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a serrated rotor leading edge to determine its effects on noise generation. The serrated rotor was produced by cutting teeth into the leading edge of the nominal rotor blades. The effects of speed and exhaust nozzle area on the scale models noise characteristics were investigated with both the nominal rotor and serrated rotor. Acoustic results indicate the serrations reduced front quadrant PNL's at takeoff power. In particular, the 200 foot (61.0 m) sideline noise was reduced from 3 to 4 PNdb at 40 deg for nominal and large nozzle operation. However, the rear quadrant maximum sideline PNL's were increased 1.5 to 3 PNdb at approach thust and up to 2 PNdb at takeoff thust with these serrated rotor blades. The configuration with the serrated rotor produced the lowest maximum 200 foot (61.0 m) sideline PNL for any given thust when the large nozzle (116% of design area) was employed.

Kazin, S. B.

Acoustic testing of a 1.5 pressure ratio, low tip speed fan (QEP fan B scale model)

A scale model (0.484 scale factor) of a single stage fan designed for a 1.5 pressure ratio and 1160 ft/sec tip speed was tested to determine its noise characteristics. The fan had 26 blades and 60 outlet guide vanes, with vanes spaced two rotor blade aerodynamic chords from the blades. The effects of speed, exhaust nozzle area and fan frame acoustic treatment on the scale model's noise characteristics were investigated.

Kazin, S. B.

Acoustic testing of a 1.5 pressure ratio low tip speed fan with casing tip bleed (QEP Fan B scale model)

A scale model of the bypass flow region of a 1.5 pressure ratio, single stage, low tip speed fan was tested with a rotor tip casing bleed slot to determine its effects on noise generation. The bleed slot was located 1/2 inch (1.3 cm) upstream of the rotor leading edge and was configured to be a continuous opening around the circumference. The bleed manifold system was operated over a range of bleed rates corresponding to as much as 6% of the fan flow at approach thrust and 4.25% of the fan flow at takeoff thrust. Acoustic results indicate that a bleed rate of 4% of the fan flow reduces the fan maximum approach 200 foot (61.0 m) sideline PNL 0.5 PNdB and the corresponding takeoff thrust noise 1.1 PNdB below the level with zero bleed. However, comparison of the standard casing (no bleed slot) and the slotted bleed casing with zero bleed shows that the bleed slot itself caused a noise increase.

Kazin, S. B.