Analysis of thermal and mechanical properties with inventory level of the molten salt storage tank in central receiver concentrating solar power plants

Molten salt thermal energy storage (TES) tanks ensure steady power output of concentrating solar power (CSP) plants; however, recent tank failures have highlighted the need for further analysis. Current studies primarily focus on analyzing the molten salt flow, heat transfer, and thermal efficiency. Additionally, research on the latest tank structures is limited and lacks newest experimental validation. This study measures temperature and molten salt inventory levels in the high-temperature tank at a 50 MW central receiver CSP plant, connected to the power grid in 2019. A multi-physics model was developed to evaluate thermal and mechanical properties of TES tanks by combining computational fluid dynamics and finite element modeling using real plant data. Heat loss, temperature, displacement, and stress distribution of the tank at different inventory levels were investigated. Results show that ambient air velocity near the tank roof reaches 2.14 m/s, much higher than 0.2 m/s near the wall. The temperatures of inventory fluid and tank are close, varying slightly at different levels due to thermal conduction and radiation. Because the heat loss strongly depends on temperature, the total tank loss remains nearly constant across inventory levels. Larger temperature gradients and thermal stresses are primarily localized along the tank floor edge and the air-salt interface. Notably, the maximum thermal stress at the tank edge is three times higher than that at the interface. The magnitude of total stress changes by less than 5 MPa with and without thermal load, indicating that high temperatures exert only a minor impact on tank stress. In contrast, thermal load significantly affects tank deformation, particularly at the roof edge, where values exceed 150 mm. Despite the large variation in molten salt levels, tank wall temperatures and displacements present a minor change, suggesting a weak correlation with inventory levels. In conclusion, the findings obtained in this study provide important insights on the TES tank that could be used to optimize tank design and operation strategies.

14 SOLAR ENERGY↗

Thermomechanical Behavior of Advanced Manufactured Parts, Subcomponents, and Their Weldments for Gen3 CSP

Generation 3 (Gen3) concentrating solar power (CSP) plants may require the use of molten chloride salt storage systems, solar receivers, and supercritical-CO 2 primary heat exchangers (PHX). The temperatures that would be expected in these parts and subcomponents could approach 760°C for hot side and 500°C for cold side at peak operating conditions. With the design limitations, highly corrosion- and creep-resistant alloys are needed for maximizing component lives. This report presents the results for the project "Thermomechanical Behavior of Advanced Manufactured Parts, Subcomponents, and their Weldments for Gen3 CSP", award number DE-EE00036334. In this project, creep enhanced ferritic alloy Grade 91, austenitic stainless-steel (SS) 304H, Ni claddings Ni201 and C22, and nickel-based superalloys Inconel 740H and Haynes 282 and 230 were evaluated for potential applications in Gen3 CSP systems. Advanced manufacturing of these parts, subcomponents and their welds, was investigated and a full technoeconomic analysis was made in comparison to conventional manufacturing techniques. The manufacturing techniques explored are explosion clad welding and combustion synthesis/combustion reaction for transfer pipes, additive manufacturing (AM) including laser-powder bed fusion (L-PBF) and electron beam AM (EBAM) with wire feedstock for PHX and solar receivers, and conventional fusion welding for similar and dissimilar joining of these various parts and subcomponents.

14 SOLAR ENERGY↗

Failure Analysis for Molten Salt Thermal Energy Storage Tanks for In-Service CSP Plants

Thermal Energy Storage (TES) is a fundamental component in concentrating solar power (CSP) plants to increase the plant's dispatchability, capacity factor, while reducing the levelized cost of electricity. In central receivers CSP plants, nitrate molten salts have been used for several years for operation temperatures of up to 565 degrees C. Despite many efforts to advance nitrate salt to higher operation temperatures (even considering a replacement with molten chloride salts) to achieve higher energy conversion efficiencies, the 565 degrees C temperature is currently considered the state-of-the art. Although molten salt tanks have been broadly deployed in commercial CSP plants worldwide, several failures have been reported in these tanks after a few months or years of operation, causing significant economic loss and mistrust in CSP technologies. Most of these failures are associated with the infancy of the technology and multiple issues related to tank design, fabrication, commissioning, and aggressive operation. A technical standard dedicated to the design and fabrication of molten nitrate TES tanks does not exist today. Current in-service molten salt tanks have been generally designed based on the American Petroleum Institute's (API) 650 and ASME Section II standards. The API 650 code provides guidelines for dimensions and fabrication for oil storage tanks up to 260 degrees C. The ASME standard provides allowable stress values for various materials at a range of temperatures and conditions. Both standards seem to be limited for molten salt TES tanks where high temperatures, thermal cycling, and transient conditions are expected. In 2020, NREL released the Concentrating Solar Power Best Practices Study (NREL/TP-5500-75763) that summarized multiple issues in CSP plants, along with potential alternatives and recommendations to address those issues based on information collected from participants representing about 80% of operating CSP plants in the world. One of the recommendations from this study was the development of accurate and validated models to evaluate the plant's transient operation, capable of capturing the effect of short-term clouds and operator response, while being flexible in being adapted to various spatial and temporal resource data. The "Failure Analysis for Molten Salt Thermal Energy Tanks for In-Service CSP Plants" project was inspired on this recommendation and was focused on (1) the development and validation of a physics-based model for a representative, commercial-scale molten salt tank, (2) performing simulations to evaluate the behavior of the tank as a function of typical plant operation conditions, (3) understanding tank failures mechanisms, (4) determining the residual stress and distortion in the tank floor after welding fabrication and evaluating their impact in the stresses developed in the tank during operation, (5) assessing the impact of key operation parameters on the temperature and stress distribution, (6) conduct a preliminary evaluation of design features to reduce stress and improve tank's reliability, and (7) estimate the tank's service life based on the stress developed under diverse operation scenarios. From the analysis conducted in the project and presented in this report, it was found that maximum stresses surpassing the yield strength point of the stainless steel (SS) 347H are developed on the tank floor near the perimeter. These large stresses are strongly influenced by the initial residual stresses and distortion of the tank floor after welding fabrication. During operation, large stresses are developed in the tank floor at high operation temperatures with large salt inventory levels during transient operation. High stresses are also related to elevated temperature gradients in the tank floor that could be attributed to insufficient mixing within the salt inflow and the salt inventory. Based on the analysis, creep is the predominant failure mechanism. However, the large stress levels could favor the plastic deformation into buckles, and crack formation due to stress relaxation cracking during cycle operation. A lifetime below 3 years was estimated for the typical plant operation conditions and a specific initial residual stress and deformation distribution of the tank floor. The estimated life agrees with the service time to failure reported in several commercial molten salt tanks. Desing and operation guidelines can be extracted from the analysis presented in this report, which could be adopted by tank manufacturers and CSP operators to advance toward an ultimate solution for tank failures by reducing residual and operational stresses to achieve a tank service life of more than 30 years. Addressing failures in molten salt TES tanks is fundamental for the CSP industry's survivability, but it is also important for other industrial and power generation applications using this technology, including nuclear and concentrating solar thermal.

14 SOLAR ENERGY↗

Low-temperature solar thermal-power systems for residential electricity supply under various seasonal and climate conditions

In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.

14 SOLAR ENERGY↗

Influence of Correlations on the Thermal Performance Modeling of Parabolic Trough Collectors

The influence of correlations on the thermal performance modeling of parabolic trough collectors was analyzed in this work. A versatile model for a parabolic trough collector was developed that allows one- and two-dimensional analysis and enables the use of correlations to calculate thermophysical properties and convection heat transfer coefficients. The model also allows the use of constant values for properties and/or coefficients obtained from the evaluation correlations at a specific temperature. The effect of each correlation was evaluated independently, and the results were compared with a reference case that considered a two-dimensional approach and used all the correlations. For the analyzed cases, the correlation for the absorber emittance has the strongest impact on the collector efficiency, leading to a lower error when used. Based on the results, a one-dimensional model approach considering a correlation for the absorber emittance leads to efficiency errors below 3% for collector lengths of up to 243.6 m. Compared with the reference case, a one-dimensional approach using all correlations for a collector with a length of 500 m, and operating with an inlet temperature of 773 K, can result in errors around 9%. However, using constant values for properties and heat transfer coefficients could lead to errors of up to 50%. Multiple thermal models for parabolic trough collectors proposed in the literature rely on a one-dimensional approach, estimated values for the heat transfer coefficients, and constant thermophysical properties. The errors associated with those approaches are analyzed and quantified in this work as a function of the collector length and operation temperature.

absorber emittance↗

Forecasting Solar-Thermal Systems Performance under Transient Operation Using a Data-Driven Machine Learning Approach Based on the Deep Operator Network Architecture

Modeling and prediction of the dynamic behavior of thermal systems operating under intermittent energy input and variable load requirements represent one of the greatest challenges in the development of efficient and reliable renewable-based power generation technologies. In this work, a data-driven machine learning modeling framework was developed based on a modified version of the Deep Operator Network architecture where the time coordinate in the trunk net is replaced with historical data of the predicting quantity. The modeling framework can be used to accurately predict the performance of renewable-based energy conversion technologies including wind- and solar-based power plants. This novel framework was applied on a solar-thermal system that consists of a solar collection loop using a flat plate collector, a power generation loop comprising an Organic Rankine Cycle, and a thermal energy storage tank connecting both loops. Variable solar irradiance, air temperature, and power load profiles were used by the Deep Operator Network to predict the State-of-Charge and the efficiency of the thermal system for several days. The results were compared with the State-of-Charge and efficiency functions calculated using a physics-based model. For a simple operation scenario, characterized by a clear sky solar irradiance profile and constant load, the standard deviation in the State-of-Charge prediction by Deep Operator Network is below 0.9% during a seven-day prediction time horizon. For the most realistic operation scenario that considers real solar irradiance and a rough load profile, the maximum standard deviation in the predictions for the State-of-Charge and efficiency are below 6.8% and 2.5%, respectively. A comparison between Deep Operator Network and Long Short Term Memory network was also performed. In general, both networks predict very well the State-of-Charge for different data density conditions; however, a higher accuracy, with a standard deviation below 2.0%, is obtained by the Deep Operator Network during three and half days using sparser training data of 20-minute points. The same accuracy for the State-of-Charge prediction with the Long Short Term Memory network is achieved only for 14 h. Average standard deviations for the State-of-Charge prediction of 1.1% with the Deep Operator Network and 1.5% with the Long Short Term Memory network are obtained for a four-day prediction time using a denser training data of 5-minute points.

DeepONet↗

Influence of the concentration ratio on the thermal and economic performance of parabolic trough collectors

The thermal and economic performance of parabolic trough collectors (PTCs) and PTCs with double glass envelope (DGE-PTCs) are analyzed in this work. A model including thermal and optical effects is developed to evaluate the efficiency of vacuum and air-filled DGE-PTCs, while an economic model based on two commercial PTCs (SkyTrough and Ultimate Trough collectors) was developed to assess the economic performance. The efficiency and thermal output per unit cost of the proposed DGE-PTCs are analyzed as a function of the concentration ratio and are respectively compared with the thermal and economic performance of traditional and commercial PTCs. The optimum concentration ratio for maximum thermal performance varies from 11.0 to 23.3 for operation temperatures (T HTF ) between 100 degrees C and 400 degrees C, while the optimum concentration ratio for maximum economic performance ranges between 28.9 and 33.2 for the SkyTrough and between 40.0 and 43.8 for the Ultimate Trough collector designs. Finally, the DGE-PTCs present higher thermal and economic performance at high operating temperatures, which presents a valuable opportunity for implementation in new PTC designs pursuing higher operating temperatures to achieve superior thermal cycle efficiencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermodynamic Modeling of Heat Engines Including Heat Transfer and Compression–Expansion Irreversibilities

In this paper, a thermodynamic model based on an endoreversible engine approach is developed to analyze the performance of heat engines operating under different thermodynamic cycles. The model considers finite heat transfer rate, variable heat source and sink temperatures, and irreversibilities associated with the expansion and compression. Expressions for the maximum power and efficiency at maximum power output are obtained as a function of hot and cold reservoir temperatures, the equivalent isentropic efficiency of compression and expansion components, and the effective conductance ratio between heat exchangers. In all cases, the Curzon–Ahlborn efficiency is retrieved at constant reservoir temperatures and neglected compression–expansion irreversibilities. The proposed model allows assessing the effect of isentropic efficiencies and heat exchanger design and operation characteristics for different thermodynamic cycles.