Engineering PapersSearch

Engineering topics

Osantowski, J. F.

Publications and source records attributed to Osantowski, J. F..

At least 19 records

Optical Technologies for UV Remote Sensing Instruments

Over the last decade significant advances in technology have made possible development of instruments with substantially improved efficiency in the UV spectral region. In the area of optical coatings and materials, the importance of recent developments in chemical vapor deposited (CVD) silicon carbide (SiC) mirrors, SiC films, and multilayer coatings in the context of ultraviolet instrumentation design are discussed. For example, the development of chemically vapor deposited (CVD) silicon carbide (SiC) mirrors, with high ultraviolet (UV) reflectance and low scatter surfaces, provides the opportunity to extend higher spectral/spatial resolution capability into the 50-nm region. Optical coatings for normal incidence diffraction gratings are particularly important for the evolution of efficient extreme ultraviolet (EUV) spectrographs. SiC films are important for optimizing the spectrograph performance in the 90 nm spectral region. The performance evaluation of the flight optical components for the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) instrument, a spectroscopic instrument to fly aboard the Solar and Heliospheric Observatory (SOHO) mission, designed to study dynamic processes, temperatures, and densities in the plasma of the upper atmosphere of the Sun in the wavelength range from 50 nm to 160 nm, is discussed. The optical components were evaluated for imaging and scatter in the UV. The performance evaluation of SOHO/CDS (Coronal Diagnostic Spectrometer) flight gratings tested for spectral resolution and scatter in the DGEF is reviewed and preliminary results on resolution and scatter testing of Space Telescope Imaging Spectrograph (STIS) technology development diffraction gratings are presented.

Keski-Kuha, R. A. M.

Optical coating technology for the EUV

Advances in optical coating and materials technology are one of the key motivators for the development of missions such as the Far Ultraviolet Spectroscopic Explorer recently selected by NASA for an Explorer class mission in the mid 1990's. The performance of a range of candidate coatings are reviewed for normal-incidence and glancing-incidence applications, and attention is given to strengths and problem areas for their use in space. The importance of recent developments in multilayer films, chemical-vapor deposited SiC (CVD-SiC) mirrors, and SiC films are discussed in the context of EUV instrumentation design. For example, the choice of optical coatings is a design driver for the selection of the average glancing angle for the FUSE telescope, and impacts efficiency, short-wavelength cut-off, and physical size.

Osantowski, J. F.

Optical design of Lyman/FUSE

The optical system for the proposed Lyman/Far UV Spectroscopic Explorer (FUSE) orbiting observatory is described and illustrated with drawings and graphs of predicted performance. The system comprises (1) an FUV channel based on a 1.84-m-diameter Rowland circle spectrograph with five high-density modified ellipsiodal near-normal-incidence gratings and an array of four MAMA detectors; (2) an EUV channel with ellipsoidal mirror, planar varied-line-space grating, microchannel-plate array, and wedge-and-strip anode detector; (3) a 70-cm Wolter II glancing-incidence telescope; and (4) a CCD-detector fine-error sensor to provide accurate pointing (within 200 marcsec rms). The resolving powers of the spectrographs are 30,000 in the FUV and 300-600 (wavelength-dependent) in the EUV.

Content, D. A.

Telescope technology for the Far Ultraviolet Spectroscopic Explorer (FUSE)

Preliminary engineering studies are in progress to define a telescope for FUSE. General science objectives include high resolution spectroscopy in the 900-1200 A spectral region, low or moderate resolution spectroscopy in the 100-900 A range, and long slit imaging over a 1-arcmin field at a spatial resolution of 1 arcsec. Telescope design studies indicate that a 1-m-diameter Wolter-Schwarzschild type II glancing-incidence telescope with an effective collecting area of 3000 sq cm is required to meet the primary science objectives. A baseline optical design has been completed, and initial alignment sensitivities derived to begin the process of error allocation for the entire system.

Osantowski, J. F.

Low earth orbit environmental effects on osmium and related optical thin-film coatings

A number of samples of optical thin film materials were flown on Shuttle flight STS-8 as part of an experiment to evaluate their interaction with residual atomic oxygen in low earth orbit. Osmium was selected because of its usefulness as a reflective optical coating for far-UV instruments and for confirmation of results from previous Shuttle flights in which such coatings disappeared. Reflectance data and photographic evidence are presented to support the hypothesis that the osmium disappearance is due to reaction with oxygen to form a volatile oxide. Platinum and iridium, which were included for comparison, fared much better.

Gull, T. R.

Layered synthetic microstructures for solar EUV telescopes

The application of layered synthetic microstructures (LSMs) to figured mirrors suitable for normal incidence solar EUV telescopes is considered, and initial studies for a single mirror telescope consisting of an f/18, 200-cm focal length off-axis paraboloid demonstrate the feasibility of LSM coatings for moderate sized mirrors. Analytical studies on broadband designs comprised of five layers show a seven percent reflectance at 256 A and reflectivities of over 12 percent for wavelengths above 300 A. Deposition considerations are also discussed.

Keski-Kuha, R. A. M.

Instrumentation studies for FUSE-Columbus

Telescope and spectrograph design for the Columbus ultraviolet astronomy satellite are described. A 1m mirror two-piece glancing incidence telescope design is suggested. A classical Rowland spectrograph is potentially the only design with efficiencies great enough to deliver the 100 sqcm net collecting area specified from a manageable telescope.

Osantowski, J. F.

Design and technology considerations for the far ultraviolet spectroscopic explorer (FUSE) telescope

An initial assessment of telescope designs satisfying the basic requirements derived for the FUSE mission is presented. A review of recent optical coating technology indicates that normal incidence telescope designs are viable only for wavelengths greater than about 600 A. It is noted that glancing incidence telescope designs, such as the Wolter Type II or thg Wolter-Schwarzschild, are the only designs with acceptable throughputs for the entire FUSE spectral range. Initial design trade studies have established the fundamental framework for the selection of an optimum Type II design satisfying the FUSE science and engineering requirements. It is also found that current optical fabrication technology, e.g., computer controlled polishing, can accommodate meter class glancing incidence components with figure errors commensurate with 1-2 arcsec imaging.

Davila, P. S. M.

Contamination sensitivity of typical mirror coatings - A parametric study

Contamination budgeting for space optical systems basically starts at understanding the sensitivity of component performance, e.g. mirror reflectance, window transmittance, etc., to surface deposits. To evaluate contamination sensitivity for mirror coatings, eight types representative of those used in the vacuum ultraviolet, visible, and infrared were modeled assuming that the contaminant is uniformly deposited on the mirror surface. Parametric studies over a range of complex refractive indices combined with an examination of optical data available for several organic materials suggested division of the contaminant layer index into three categories, N = 1.5 + 0.1i, N = 1.5 + 0.5i, and N = 1.5 + 2.0i. Contaminant thickness sensitivity curves were then calculated for each of the selected mirror coatings. For comparative purposes, critical thicknesses for each type were extracted, assuming a reflectance loss of 10 percent was allowable. Critical thicknesses ranged from about 10 A to 1000 A depending on the specifics of coating design and spectral region.

Osantowski, J. F.

Optical constants in the extreme ultraviolet and soft X-ray region

The nature of optical constants and their measurement by reflection or absorption techniques in the extreme ultraviolet and soft X-ray spectral region from 30 to 3000 eV is discussed with emphasis on mirror design. Sources of optical constant data are mentioned and reflectance measurements for SiC and Kanigen between 40 and 200 eV are reported.

Rife, J. C.

Auger spectroscopic examination of MgF2-coated Al mirrors before and after UV irradiation

Magnesium fluoride protected Al films were studied since these mirrors are commonly used in astronomical instruments whenever a highly reflecting optical surface is required in the wavelength region from 1100 A to 2000 A. Freshly prepared samples of evaporated Al + 250-A thick MgF2 on glass were analyzed by Auger electron spectroscopy in conjunction with surface erosion by Ar(+) ion bombardment before and after UV irradiation. The analysis showed that a very thin layer of surface contamination and not bulk photolysis in the MgF2 film was reponsible for the irradiation-induced reflectance loss. Postirradiation polishing with a mild calcium carbonate abrasive can restore a mirror's reflectance by removing the photolyzed surface film without disturbing the MgF2 layer.

Heaney, J. B.

Reflectance and optical constants for Cer-Vit from 250 to 1050 A

The reflectance for a bowl-feed polished Cer-Vit sample was measured at nine wavelengths and five angles of incidence from 15 to 85 deg. Optical constants were derived by the reflectance-vs-angle-of-incidence method and compared to previously reported values for ultralow-expansion fused silica and several other glasses. Surface-roughness corrections of the reflectance data and optical constants are discussed.

Osantowski, J. F.

Broadband ultraviolet reflectance filters for space applications.

It is shown that a simple metal-dielectric-metal filter for broadband ultraviolet (BUV) reflectance control can provide a stable and effective means for reducing stray visible radiation in UV reflective optical systems. The application of such a filter in a BUV instrument resulted in a reduction of scattered visible light by at least an order of magnitude. The instrument has been in orbit for 2.5 year without loss of sensitivity or an increase in scattered light background.-

Osantowski, J. F.

An extreme UV photometer for solar observations from Atmosphere Explorer.

A broadband photometer experiment is being prepared for the Atmosphere Explorer-C, -D, and -E missions to record the solar irradiance in seven wavelength bands in the range from 40 to 1250 A. The experiment contains four spiral electron multipliers located behind a moving eight-position filter wheel. Six of the eight sections of this wheel contain metallic filters used to spectrally isolate the solar irradiance. In addition, three Al2O3 diodes, two with filters, are being used to record the solar irradiance over the full range of orbital altitudes including those at which operation of multipliers with high voltages on open structures would be unsafe. A principal goal of the experiment will be to measure time dependence of the solar irradiance.

Heath, D. F.

An extreme ultraviolet photometer for solar observations from the Atmosphere Explorer satellites

A broadband photometer experiment is being fabricated for the Atmosphere Explorer C, D and E missions to record the solar irradiance in the 40 to 1250 A region with seven distinct passbands. The experiment consists principally of four spinal electron multipliers located behind a moving eight position filter wheel. Six metallic filters are used to spectrally isolate the solar irradiance. In addition three Al2O3 diodes, two with filters, are being used to record the solar irradiance over the range of orbital altitudes from perigee through apogee. A principal goal of the experiment will be to measure time dependence of the solar irradiance with respect to a storage ring synchrotron light source which has been calibrated in terms of the best currently available standards of irradiance.

Heath, D. F.

Side-viewing detector for a vacuum ultraviolet reflectometer.

The problem of detector response, which arises in the application of the reflectance vs angle of incidence method to the determination of optical constants in the vacuum UV spectral region is discussed. The analysis is performed for the side-viewing 1P21 detector sensitized with sodium salycilate. To take advantage of the wide selection photomultipliers available in the end-on configuration, a scheme for converting the end-on types to a side viewing geometry with a response uniform over several degrees of detector rotation is developed. It consists of a 32-mm diam spherical collector, located at the end of a cylindrical photomultiplier holder, with 12-mm entrance and viewing ports and a position for the sensitized screen also 12-mm in diameter.-

Osantowski, J. F.