Engineering Papers⌕ Search

Engineering topics

Opachich, Yekaterina

Publications and source records attributed to Opachich, Yekaterina.

FY2024 Q4 L2 Milestone 8237 for Opacity-on-NIF

This document addresses parts 2 and 3 of the original milestone request. In the following writeup, the development of OpSpecTR at LLNL by LLNL and NNSS personnel will be detailed first, followed by a write-up of the development of Vme-resolved simulaVons of the opacity-on-NIF experiment. Capsule backlight simulaVons, hohlraum simulaVons, and sample simulaVons from CASSIO are combined to produce the line of sight from the capsule to an effecVve OpSpec posiVon. Spectra are generated by post-processing these simulaVons from either Spect3D, a commercial software by Prism ComputaVonal Sciences, or FESTR (Finite Element Spectroscopic Transport of RadiaVon), a LANL code. While the simulaVons do not at this stage proceed late enough to include the worst of the backgrounds generated from the hohlraum experimentally and each post-processing simulaVon includes only one ray for each spectrometer channel, these efforts represent proof of concept for a new capability to complete Vme-resolved and Vmegated simulaVons for the complete line of sight of the complex opacity-on-NIF geometry. Future work will be discussed at the end of the report for both efforts.

42 ENGINEERING↗

Implementation of a 1-2 keV point-projection x-ray spectrometer on the National Ignition Facility

A point-projection soft X-ray Opacity Spectrometer (OpSpec) has been implemented to measure X-ray spectra from ~1 to 2 keV on the National Ignition Facility (NIF). Measurement of such soft X-rays with open-aperture point-projection detectors is challenging because only very thin filters may be used to shield the detector from the hostile environment. OpSpec diffracts X-rays from 540 to 2100 eV off a potassium (or rubidium) acid phthalate (KAP or RbAP) crystal onto either image plates or, most recently, X-ray films. A “sacrificial front filter” strategy is used to prevent crystal damage, while 2 or 3 rear filters protect the data. Since May 2017, OpSpec has been recording X-ray transmission data for iron-magnesium plasmas on the NIF, at “Anchor 1” plasma conditions (temperature ~150 eV, density ~7 × 10 21 e - /cm 3 ). Upgrades improved OpSpec’s performance on 6 NIF shots in August and December 2017, with reduced backgrounds and 100% data return using filter stacks as thin as 2.9 μm (total). We conclude that photometric noise is beginning to meet requirements, and further work will reduce systematic errors.

47 OTHER INSTRUMENTATION↗

Photocathode

A photocathode designs that leverage the grazing incidence geometry yield improvements through the introduction of recessed structures, such as cones, pyramids, pillars or cavities to the photocathode substrate surface. Improvements in yield of up to 20 times have been shown to occur in grazing incidence geometry disclosed herein due to a larger path length of the X-ray photons which better matches the secondary electron escape depth within the photocathode material. A photocathode includes a substrate having a first side and a second side, the first side configured to receive x-ray energy and the second side opposing the first side. A structured surface is associated with the second side of the substrate such that the structured surface includes a plurality of recesses from the second side of the substrate into the substrate.

36 MATERIALS SCIENCE↗