Engineering PapersSearch

Engineering topics

Obayashi, T.

Publications and source records attributed to Obayashi, T..

Spacelab 1 experiments on interactions of an energetic electron beam with neutral gas

An unusual signature of return current and spacecraft charging potential was observed during the Spacelab 1 mission launched on November 28, 1983. The phenomenon occurred during neutral gas releases from the SEPAC (Space Experiments with Particle Accelerators) magnetoplasma-dynamic arcjet (MPD) concurrent with firings of the PICPAB (Phenomena Induced by Charged Particle Beams) electron gun and was recorded by the instruments of the SEPAC diagnostic package (DGP). Data from the langmuir probe, floating probes, neutral gas pressure gauge, and the plasma wave probes are reported. As the dense neutral gas was released, the return current measured by the langmuir probe changed from positive to negative and a positive potential relative to the spacecraft was measured by the floating probe. The anomalous return current is believed to be attributable to secondary electron fluxes escaping from the spacecraft, and the unusual charging situation is attributed to the formation of a double-layer structure between a hot plasma cloud localized to the MPD and the spacecraft. The charging scenario is supported by a computer simulation.

Marshall, J. A.

Results from a series of tethered rocket experiments

This paper reports the results of three tethered rocket experiments conducted as part of a U.S.-Japan joint program under way since 1980. The major purpose of the experiments is to obtain technical and scientific data supporting the figure electrodynamic tethered subsatellite experiments by the Space Shuttle. Vehicle charging due to dc beam emission up to 80 mA in the 150-200 km altitude range was repeatedly measured by both Langmuir and floating probes, and was found to be usually less than 10 V. During the 80 mA emission, clear evidence for the ignition of a beam-plasma discharge was obtained. In a tether deployment experiment, it was found that the tether wire acted as an antenna whose impedance decreased with the extension of the wire both in high-frequency and very low-frequency bands. Substantial rocket charging was observed during periods of electron-beam very low-frequency pulsing.

Sasaki, S.

Neutralization of beam-emitting spacecraft by plasma injection

An impulsive plasma injection has been used to study charge neutralization of the Space Shuttle Orbiter while it was emitting an electron beam into space. This investigation was performed by Space Experiments with Particle Accelerators on Spacelab-1. A plasma consisting of 10 to the 19th argon ion-electron pairs was injected into space for 1 ms while an electron beam was also being emitted into space. The electron beam energy and current were as high as 5 keV and 300 mA. While the orbiter potential was positive before the plasma injection and began to decrease during the plasma injection, it was near zero for 6 to 20 ms after the plasma injection. The recovery time to the initial level of charging varied from 10 to 100 ms. In a laboratory test in a large space chamber using the same flight hardware, the neutralization time was 8-17 ms and the recovery time was 11-20 ms. The long duration of the neutralization effect in space can be explained by a model of diffusion of the cold plasma which is produced near the Orbiter by charge exchange between the neutral argon atoms and the energetic argon ions during plasma injection.

Sasaki, S.

Results from a series of US/Japan tethered rocket experiments

Tethered rocket experiments have been carried out four times during a US-Japan joint space program in progress since 1980. The goal of the rocket program has been to perform a new type of active experiment by ejecting an electron beam from the tethered mother-daughter payload system. In the third and fourth rocket flights, the conductive tether wire was deployed more than 400 m. It was found that the tether wire acted as an antenna and its antenna impedance decreased with the extension of the wire both in HF and VLF bands. The vehicle charging due to the beam emission up to 80 mA was repeatedly measured in the series of the experiments. During the 80 mA emission, a clear evidence for the ignition of a beam plasma discharge was obtained by the plasma probe, photometers and wave receivers.

Sasaki, S.

Gas ionization induced by a high speed plasma injection in space

Gas ionization induced by a fast plasma injection has been observed with the Space Experiments with Particle Accelerators (SEPAC) Experiment on Spacelab-1. When an impulsive high-density plasma was injected from the orbiter, waves near the lower-hybrid frequency were enhanced, and the surrounding gas drifting with the orbiter was ionized for several tens of milliseconds after the plasma injection. The long-duration gas ionization was observed only when the plasma flux incoming to the orbiter cargo bay and the orbital velocity perpendicular to the magnetic field were relatively large. This effect has been explained by the concept of critical velocity ionization (CVI) for the gas drifting with the orbiter, although the gas velocity perpendicular to the magnetic field was less than the Alfven critical velocity.

Sasaki, S.

Wave-particle interactions induced by SEPAC on Spacelab 1 Wave observations

Space experiments with particle accelerators (SEPAC) flew on Spacelab 1 in November and December 1983. SEPAC included an accelerator which emitted electrons into the ionospheric plasma with energies up to 5 keV and currents up to 300 mA. The SEPAC equipment also included an energetic plasma generator, a neutral gas generator, and an extensive array of diagnostics. The diagnostics included plasma wave detectors, and energetic electron analyzer, a photometer, a high sensitivity television camera, a Langmuir probe and a pressure gage. Twenty-eight experiments were performed during the mission to investigate beam-plasma interactions, electron beam dynamics, plasma beam propagation, and vehicle charging. The wave-particle interactions were monitored by the plasma wave instrumentation, by the energetic electron detector and by the optical detectors. All show evidence of wave-particle interactions, which are described in this paper.

Taylor, W. W. L.

Initial results of SEPAC scientific achievement

Electron beam injection of 5 keV, 300 mA (1.5 kW) and MPD arcjet plasma injection of 2 kJ/shot were successfully performed together with various kinds of diagnostic instruments including a high sensitivity TV camera observation in the Spacelab 1. Major scientific results obtained are studies of: (1) vehicle charge-up due to the electron beam emission and its neutralization by the MPD arcjet plasma; (2) beam-plasma interaction including the plasma wave excitation; (3) beam-atmosphere interaction such as the verification of critical velocity ionization effect; and (4) anomalous enhancement of ionization associated with a neutral gas injection into space.

Obayashi, T.

An enhancement of plasma density by neutral gas injection observed in SEPAC Spacelab-1 experiment

An enhancement of plasma density observed during a neutral gas injection in Space Experiments with Particle Accelerators by the Space Shuttle/Spacelab-1 is presented. When a plume of nitrogen gas was injected from the orbiter into space, a large amount of plasma was detected by an onboard plasma probe. The observed density often increased beyond the background plasma density and was strongly dependent on the attitude of the orbiter with respect to the velocity vector. This effect has been explained by a collisional interaction between the injected gas molecules and the ionospheric ions relatively drifting at the orbital speed.

Sasaki, S.

Space experiments with particle accelerators

Electron and plasma beams and neutral gas plumes were injected into the space environment by instruuments on Spacelab 1, and various diagnostic measurements including television camera observations were performed. The results yield information on vehicle charging and neutralization, beam-plasma interactions, and ionization enhancement by neutral beam injection.

Obayashi, T.

Early experiments in charged particle beams from the Space Shuttle

Characteristics of studies on board the Shuttle involving the interaction of particle beams with the atmosphere and the ionosphere, and the effects of the beams on the electrical potential of the platform, are discussed. Noting that the Shuttle allows greater weight and power demands by scientific payloads than previous satellite launches, the OSS-1 Vehicle Charging and Potential experiment and the Spacelab 1 Particle Accelerator and Phenomena Induced by Charged Particle Beams are described. Instrumentation details are provided, including charge and current probes, the Spherical Retarding Potential Analyzer, the Fast Pulse Electron Generator, and digital control and interface units. The SEPAC equipment, which comprises an electron beam accelerator, and MPD plasma jet, and diagnostic units are detailed, and operating procedures and experiment objectives are outlined.

Raitt, W. J.

Space Experiments with Particle Accelerators (SEPAC)

Plans for SEPAC, an instrument array to be used on Spacelab 1 to study vehicle charging and neutralization, beam-plasma interaction in space, beam-atmospheric interaction exciting artificial aurora and airglow, and the electromagnetic-field configuration of the magnetosphere, are presented. The hardware, consisting of electron beam accelerator, magnetoplasma arcjet, neutral-gas plume generator, power supply, diagnostic package (photometer, plasma probes, particle analyzers, and plasma-wave package), TV monitor, and control and data-management unit, is described. The individual SEPAC experiments, the typical operational sequence, and the general outline of the SEPAC follow-on mission are discussed. Some of the experiments are to be joint ventures with AEPI (INS 003) and will be monitored by low-light-level TV.

Obayashi, T.

Space experiments with particle accelerators

The purpose of space experiments with particle accelerators (SEPAC) is to carry out active and interactive experiments on and in the Earth's ionosphere and magnetosphere. It is also intended to make an initial performance test for an overall program of Spacelab/SEPAC experiments. The instruments to be used are an electron beam accelerator, magnetoplasma dynamic arcjet, and associated diagnostic equipment. The accelerators are installed on the pallet, with monitoring and diagnostic observations being made by the gas plume release, beam-monitor TV, and particle-wave measuring instruments also mounted on the pallet. Command and display systems are installed in the module. Three major classes of investigations to be performed are vehicle charge neutralization, beam plasma physics, and beam atmosphere interactions. The first two are mainly onboard plasma physics experiments to measure the effect of phenomena in the vicinity of Spacelab. The last one is concerned with atmospheric modification and is supported by other Spacelab 1 investigations as well as by ground-based, remote sensing observations.

Obayashi, T.

Hydromagnetic whistlers.

Hydromagnetic whistlers considered as overlapping wavetrains generated by particle interaction and propagating along field aligned paths in magnetosphere

PLASMA-PARTICLE INTERACTION

Space Radio Patrol

Radio research in United States satellite program and whip and/or loop antennas for use in space radio patrol

LOOP ANTENNA