Engineering Papers⌕ Search

Engineering topics

O'Connell, R

Publications and source records attributed to O'Connell, R.

An upgraded x-ray spectroscopy diagnostic on MST

An upgraded x-ray spectroscopy diagnostic is used to measure the distribution of fast electrons in MST and to determine Z{sub eff} and the particle diffusion coefficient D{sub r}. A radial array of 12 CdZnTe hard-x-ray detectors measures 10-150 keV Bremsstrahlung from fast electrons, a signature of reduced stochasticity and improved confinement in the plasma. A new Si soft-x-ray detector measures 2-10 keV Bremsstrahlung from thermal and fast electrons. The shaped output pulses from both detector types are digitized and the resulting waveforms are fit with Gaussians to resolve pileup and provide good time and energy resolution. Lead apertures prevent detector saturation and provide a well-known etendue, while lead shielding prevents pickup from stray x-rays. New Be vacuum windows transmit >2 keV x-rays, and additional Al and Be filters are sometimes used to reduce low energy flux for better resolution at higher energies. Measured spectra are compared to those predicted by the Fokker-Planck code CQL3D to deduce Z{sub eff} and D{sub r}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equilibrium evolution in oscillating-field current-drive experiments

Oscillating-field current drive (OFCD) is a proposed method of steady-state toroidal plasma sustainment in which ac poloidal and toroidal loop voltages are applied to produce a dc plasma current. OFCD is added to standard, inductively sustained reversed-field pinch plasmas in the Madison Symmetric Torus [R. N. Dexter et al., Fusion Technol. 19, 131 (1991)]. Equilibrium profiles and fluctuations during a single cycle are measured and analyzed for different relative phases between the two OFCD voltages and for OFCD off. For OFCD phases leading to the most added plasma current, the measured energy confinement is slightly better than that for OFCD off. By contrast, the phase of the maximum OFCD helicity-injection rate also has the maximum decay rate, which is ascribed to transport losses during discrete magnetic-fluctuation events induced by OFCD. Resistive-magnetohydrodynamic simulations of the experiments reproduce the observed phase dependence of the added current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of energetic electron confinement in a largely stochastic reversed-field pinch plasma

Runaway electrons with energies >100 keV are observed with the appearance of an m=1 magnetic island in the core of otherwise stochastic Madison Symmetric Torus [Dexter et al., Fusion Technol. 19, 131 (1991)] reversed-field-pinch plasmas. The island is associated with the innermost resonant tearing mode, which is usually the largest in the m=1 spectrum. The island appears over a range of mode spectra, from those with a weakly dominant mode to those, referred to as quasi single helicity, with a strongly dominant mode. In a stochastic field, the rate of electron loss increases with electron parallel velocity. Hence, high-energy electrons imply a region of reduced stochasticity. The global energy confinement time is about the same as in plasmas without high-energy electrons or an island in the core. Hence, the region of reduced stochasticity must be localized. Within a numerical reconstruction of the magnetic field topology, high-energy electrons are substantially better confined inside the island, relative to the external region. Therefore, it is deduced that the island provides a region of reduced stochasticity and that the high-energy electrons are generated and well confined within this region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multipoint Thomson scattering diagnostic for the Madison Symmetric Torus reversed-field pinch

The multipoint Thomson scattering diagnostic on the Madison Symmetric Torus (MST) is now fully operational with 21 spatial points, which cover the entire minor radius. Four full electron temperature profiles can be obtained during each MST discharge, with a variable delay between each profile. This system overcomes challenges that arise from the unique machine design, location, and plasma characteristics of MST. The machine design limits the maximum porthole diameter to 11.4 cm, requiring a compact, re-entrant, seven element lens for scattered light collection. Limited space near MST necessitates a long beam path for the two Nd:YAG lasers requiring a remote beam line adjustment system to suppress drift in the beam position due to thermal expansion of the building. Due to the remote location of the laser head, substantial design effort was put into the creation of a set of safety interlocks for the laser system. The dynamic nature of MST plasmas and the wide range of operating space require a versatile scattered light detection system consisting of filter polychromators with temperature controlled avalanche photodiode detectors. We also implement an insertable integrating sphere, which travels along the laser beam path through the vacuum vessel, for the alignment of both the fiber optics and the lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing a Thomson scattering diagnostic for fast dynamics and high background

The Madison Symmetric Torus (MST) presents challenging conditions for Thomson scattering (TS) measurements. The MST plasmas are reversed-field pinches (RFPs) with electron density n{sub e}<3x10{sup 13} cm{sup -3}, typically 1x10{sup 13} cm{sup -3}. The TS system was designed to measure from 10 eV to 2 keV; however, six polychromators were upgraded from four to eight spectral channels to resolve to 10 keV. There is no diverter or vertical field, so wall interaction results in high background light both from ion and neutral bremsstrahlungs and from line radiation. Also during standard plasmas, the RFP exhibits regular reconnection sawteeth events during which the plasma current, density, and temperature profiles are flattened. These events are of interest both due to the reconnection physics and to their contribution to the MST equilibrium and confinement. These events occur over 100 {mu}S and exhibit large changes in background light and fast changes in temperature. During improved confinement plasmas, there are no sawteeth; the background is low but the temperature can be over an order of magnitude higher. Data analysis of the system has been developed to accommodate both the large dynamic range of the temperature, the fast dynamics, and the fast changing, high amplitude background. Special attention has been paid to the sources of error, in particular, the contribution of the background. A response-function method reduces the measured uncertainty by a factor of 2. Numerical techniques have been developed which are extremely robust. Two methods are used, a conventional {chi}{sup 2} minimization using a Levenberg-Marquardt algorithm coupled with Monte Carlo modeling for the error bar and a Bayesian statistics method. The Bayesian method computes the probability distribution for the measured photons and electron temperature and this information can be used to ensemble data and will allow future integrated data analysis efforts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of a Thomson scattering diagnostic for fluctuation measurements

Detailed calibrations of the Madison Symmetric Torus polychromator Thomson scattering system have been made suitable for electron temperature fluctuation measurements. All calibrations have taken place focusing on accuracy, ease of use and repeatability, and in situ measurements wherever possible. Novel calibration processes have been made possible with an insertable integrating sphere (ISIS), using an avalanche photodiode (APD) as a reference detector and optical parametric oscillator (OPO). Discussed are a novel in situ spatial calibration with the use of the ISIS, the use of an APD as a reference detector to streamline the APD calibration process, a standard dc spectral calibration, and in situ pulsed spectral calibration made possible with a combination of an OPO as a light source, the ISIS, and an APD used as a reference detector. In addition a relative quantum efficiency curve for the APDs is obtained to aid in uncertainty analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-{beta}, improved confinement reversed-field pinch plasmas at high density

In Madison Symmetric Torus [Dexter et al., Fusion Technol. 19, 131 (1991)] discharges where improved confinement is brought about by modification of the current profile, pellet injection has quadrupled the density, reaching n{sub e}=4x10{sup 19} m{sup -3}. Without pellet injection, the achievable density in improved confinement discharges had been limited by edge-resonant tearing instability. With pellet injection, the total beta has been increased to 26%, and the energy confinement time is comparable to that at low density. Pressure-driven local interchange and global tearing are predicted to be linearly unstable. Interchange has not yet been observed experimentally, but there is possible evidence of pressure-driven tearing, an instability usually driven by the current gradient in the reversed-field pinch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Beta, Improved Confinement Reversed-Field Pinch Plasmas at High Density

In Madison Symmetric Torus Dexter et al., Fusion Technol. 19, 131 1991 discharges where improved confinement is brought about by modification of the current profile, pellet injection has quadrupled the density, reaching ne=41019 m 3. Without pellet injection, the achievable density in improved confinement discharges had been limited by edge-resonant tearing instability. With pellet injection, the total beta has been increased to 26%, and the energy confinement time is comparable to that at low density. Pressure-driven local interchange and global tearing are predicted to be linearly unstable. Interchange has not yet been observed experimentally, but there is possible evidence of pressure-driven tearing, an instability usually driven by the current gradient in the reversed-field pinch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗