Engineering Papers⌕ Search

Engineering topics

Novick, R.

Publications and source records attributed to Novick, R..

At least 37 records · Page 2

Stellar and solar X-ray polarimetry

The theory of Bragg crystal X-ray polarimeters is presented together with an analysis of the statistics of photon-limited polarimeters. The focusing Bragg crystal polarimeter flown on the OSO-8 Satellite is described and a number of results obtained at 2.6 keV and 5.2 keV are presented. A polarimeter of this type with at least ten times the area is needed to answer a number of astrophysically interesting questions. A discussion is given of a Compton scattering polarimeter that is expected to be useful of energies above 40 keV. It is shown how this polarimeter may be used to test for the presence of a black hole in Cyg X-1. A solar flare X-ray polarimeter that is scheduled to be flown on an early space shuttle mission is described and an estimate is given of its sensitivity.

Novick, R.↗

Data reduction and analysis for the graphite crystal X-ray spectrometer and polarimeter experiment flown aboard OSO-8 spacecraft

The documentation and software programs developed for the reception, initial processing (quickbook), and production analysis of data obtained by solar X-ray spectroscopy, stellar spectroscopy, and X-ray polarimetry experiments on OSO-8 are listed. The effectiveness and sensitivity of the Bragg crystal scattering instruments used are assessed. The polarization data polarimetric data obtained shows that some X-ray sources are polarized and that a larger polarimeter of this type is required to perform the measurements necessary to fully understand the physics of X-ray sources. The scanning Bragg crystal spectrometer was ideally suited for studying rapidly changing solar conditions. Observations of the Crab Nebula and pulsar, Cyg X-1, Cyg X-2, Cyg X-3, Sco X-1, Cen X-3, and Her X-1 are discussed as well as of 4U1656-53 and 4U1820-30. Evidence was obtained for iron line emission from Cyg X-3.

Novick, R.↗

The X-ray polarization of the Cygnus sources

Multiple observations of Cygnus X-1, Cygnus X-2, and Cygnus X-3 were carried out with the Bragg crystal polarimeters aboard OSO 8. Of these sources, an unambiguous detection of the time-averaged polarization was obtained only for Cygnus X-1, which has a polarization of 2.4% plus or minus 1.1% at 2.6 keV and 5.3% plus or minus 2.5% at 5.2 keV. While statistically significant evidence for polarization of Cygnus X-2 of 4.9% at 2.6 keV was obtained in a 1975 observation, this result was not confirmed in later observations. For Cygnus X-3, modulation of the observed flux at twice the rotation frequency of the satellite, the signature of polarization, was also detected, but spurious modulation due to the presence of additional sources in the field of view cannot be ruled out.

Long, K. S.↗

A high resolution gas scintillation proportional counter for studying low energy cosmic X-ray sources

In recent years much effort has been devoted to the development of large area gas scintillation proportional counters (GSPCs) suitable for use in X-ray astronomy. The paper deals with a low-energy GSPC for use in detecting sub-keV X-rays from cosmic sources. This instrument has a measured energy resolution of 85 eV (FWHM) at 149 eV over a sensitive area of 5 sq cm. The development of imaging capability for this instrument is discussed. Tests are performed on the feasibility of using an arrangement of several phototubes placed adjacent to one another to determine event locations in a large flat counter. A simple prototype has been constructed and successfully operated.

Hamilton, T. T.↗

Thermal X-ray emission from neutron stars

In the present paper, the status of theories concerning the thermal properties of neutron stars are reviewed, and means by which observational astronomy may contribute to future studies are examined. Particular attention is given to program of the Einstein Observatory (HEAO 2) which calls for observations of over 50 SNR and 35 radio pulsars. The present paper includes a survey of all objects within 350 pc of the earth.

Helfand, D. J.↗

The linear X-ray polarization of Scorpius X-1

Scorpius X-1 was observed with the Bragg crystal polarimeters aboard OSO 8 in August 1977 and again in August 1978. An analysis of these observations reveals a time-averaged polarization of 0.39% plus or minus 0.20% at 2.6 keV and 1.31% plus or minus 0.40% at 5.2 keV. The corresponding position angles are 29 deg plus or minus 10 deg and 57 deg plus or minus 6 deg, respectively. Binary phase-dependent polarization was searched for but not observed.

Long, K. S.↗

The first search for X-ray polarization in the Centaurus X-3 and Hercules X-1 pulsars

The first search for X-ray polarization in the Cen X-3 and Her X-1 pulsars was performed by the OSO 8 polarimeters in 1975 July and 1975 August, respectively. Three-sigma upper limits to the polarization in Cen X-3 of 13.5% and 19% at 2.6 keV and 5.2 keV, respectively, were obtained when the data were averaged over the pulse and binary periods. The upper limit for Her X-1 at 2.6 keV is 60%. A search for pulse-phase dependent X-ray polarization from both objects was also performed. At the 91% confidence level, emission from Cen X-3 exhibits evidence for X-ray polarization at 2.6 keV that varies with pulse phase. Upper limits to polarization are presented for the leading and trailing edges and peak of the Her X-1 pulse at 2.6 keV.

Silver, E. H.↗

Further comments on the effects of vacuum birefringence on the polarization of X-rays emitted from magnetic neutron stars

The birefringence of the vacuum in the presence of strong (of the order of 1 teragauss) magnetic fields will in general affect the polarization of X-rays propagating through these fields. Two of the four Stokes parameters will vary so rapidly with wavelength as to be 'washed out' and unobservable, but the remaining two parameters will be unaffected. These results show that one conclusion of an earlier work is incorrect: Polarized X-ray emission from the surface of a magnetic neutron star will not in general be completely depolarized by the effects of vacuum birefringence. In particular, this birefringence has no effect on the linear polarization of cyclotron emission from the poles of magnetic neutron stars, and a similar result holds for synchrotron emission. More general cases of the propagation of polarized X-rays in magnetic fields are also discussed.

Chanan, G. A.↗

A drift multiwire proportional counter for cosmic soft X-ray imaging

Multiwire proportional counters with 1 micrometer polypropylene windows, of dimensions 75 mm x 75 mm and 100 mm x 100 mm, have been built to map soft cosmic X-rays. The counters are constructed with a large drift region which makes it possible to use the center-of-gravity technique to improve the counter's efficiency and position resolution. Using 330 torr of propane as the gas fill and an anode plane composed of 20 micrometer diameter, gold-plated tungsten wire spaced 1mm apart, a position resolution of better than 280 micrometers (FWHM) in two orthogonal directions at an X-ray energy of 0.94 keV was achieved.

Reid, P. B.↗

X-ray polarimetry

The method by which the Bragg-crystal X-ray polarimeters aboard Ariel 5 and OSO 8 operate is briefly described, and some results obtained with these instruments for six Galactic X-ray sources are summarized. A precision measurement of the linear polarization in the Crab Nebula at energies of 2.6 and 5.2 keV is presented. Evidence is given for polarization in Sco X-1, Cyg X-2, Cen X-3, and the X-ray transient A0620-00. The determined or estimated polarizations are approximately 19.2% at 2.6 keV and 19.5% at 5.2 keV for the Crab Nebula, 1.1% at 2.6 keV and 2.4% at 5.2 keV for Sco X-1, 2.5% at 2.6 keV and 9.8% at 5.2 keV for Cyg X-1, an upper limit of 13.5% for A0620-00, an upper limit of 13.5% to the time-averaged polarization of Cen X-3, and an apparent value of about 5% for Cyg X-2.

Long, K. S.↗

Bragg crystal spectroscopy on the OSO 8 satellite

Results are reported for high-resolution OSO 8 Bragg-crystal spectroscopy of a variety of cosmic X-ray sources in the energy range from 2 to 10 keV. A continuous spectrum of Sco X-1 is examined, and results of a search for narrow line emission due to iron near 6.7 keV are presented for 32 galactic X-ray sources, including Sco X-1, Cyg X-3, and Cen X-3. It is noted that the strongest evidence for iron line emission has been obtained for Cyg X-3 and that evidence for an iron line feature has also been found in the spectrum of Cen X-3.

Long, K. S.↗

Imaging proportional counter for X-ray astronomy

A position-sensitive proportional counter capable of imaging X-rays (0.1-3 keV) over a 10 cm x 10 cm aperture has been constructed. Positioning is obtained by sensing the signals induced by an X-ray event on the two orthogonal sets of cathode wires. Each cathode is divided into a series of cathode strips, each 0.5 cm wide. An X-ray event induces signals on several adjacent strips. Signals from each cathode strip are amplified separately and then added in an equally weighted and an unequally weighted summing amplifier. The position in each direction is obtained by dividing the output of the unequally weighted summer by that of the equally weighted summer. At 0.94 keV, the accuracy of the position sensing is 190 microns. At the same energy, the energy resolution is approximately 65% (FWHM). The proportional counter system is currently being incorporated into a sounding rocket payload having metal mirror optics, which is being constructed by the X-ray astronomy group at the California Institute of Technology.

Long, K. S.↗

Silicon X-ray line emission from solar flares and active regions

New observations of solar flare and active region X-ray spectra obtained with the Columbia University instrument on OSO-8 are presented and discussed. The high sensitivity of the graphite crystal panel has allowed both line and continuum spectra to be served with moderate spectral resolution. Observations with higher spectral resolution have been made with a panel of pentaerythritol crystals. Twenty-nine lines between 1.5 and 7.0 A have been resolved and identified, including several dielectronic recombination satellite lines to Si XIV and Si XIII lines which have been observed for the first time. It has been found that thermal continuum models specified by single values of temperature and emission measure have fitted the data adequately, there being good agreement with the values of these parameters derived from line intensity ratios.

Parkinson, J. H.↗

Search for X-ray polarization in the Crab pulsar

Results of a search for X-ray polarization in the Crab pulsar are presented which were obtained by observing the pulsar at 2.6 and 5.2 keV with identical X-ray polarimeters aboard OSO 8. The polarization in different portions of the X-ray light curve is analyzed, the polarization contribution due to the nebula is removed, and the results of the analysis are given for isolated portions of both the primary pulse and the interpulse at 2.6 and 5.2 keV. No evidence for X-ray polarization is found at the 99% confidence level; 3-sigma upper limits to the polarization at 2.6 keV are given along with the largest polarization allowed at 5.2 keV by the 99% confidence counter. It is noted that the trailing edge of the interpulse at 2.6 keV is 26% polarized at the 92% confidence level, while the 5.2-keV polarization measurement of 40% in the leading edge of the primary pulse is different from zero at 96% confidence. X-ray and optical polarization measurements are compared.

Silver, E. H.↗

Joint observations of 4U1223-62 by the SAS-3 satellite and Columbia University proportional counter experiment on NASA rocket 26.054 UH

The pulsating X-ray binary 4U1223-62 and Vela X-1 were observed by Aerobee rocket-borne proportional counters. Valid X-ray events were telemetered and analyzed for possible flaring, quasiperiodic, and periodic pulsations, and for other nonstatistical behavior in the source. Both fast Fourier transform and autocorrelation programs were used. For several hours four days before and after the rocket flight, the SAS-3 satellite scanned the galactic plane in order to identify X-ray sources in the vicinity of 4U1223-62 and their intensities, and to provide positional accuracy of 0.25 for sources with intensity greater than 10% of the target. Observations of the source near the main peak of its pulsating period as defined by SAS-3 are discussed. There is no evidence of a spectral feature although twice as many photons were received as than from Vela X-1.

Novick, R.↗

Gamma ray polarimetry

Spectroscopic instruments currently being proposed may possess polarimetric capabilities which sould be nurtured and enhanced to permit characterization of basic emission mechanisms which are impossible using other techniques. Compton scattering and pair production detected the polarization of high energy (E is greater than 50 keV) protons in laboratory experiments. The polarization properties of a detection system consisting of 19 germanium crystals in a closed packed array are examined and the advantages of such a detector over Thompson scattering are discussed. The possiblity of using pair production to detect polarization of high energy gamma rays, and the associated modulation factors are discussed. The central difficulty involved in using pair production polarimeters in astrophysical applications is that the typical opening of the electron or positron direction with respect to the incident photon aircitron is small, of order E/sq mc. Multiple scattering in the material used to convert the photons to an electron positron pair causes deviations in the direction of the electron and positron.

Long, K. S.↗

Search for X-ray line emission from Cassiopeia A

The large area graphite crystal spectrometer aboard OSO 8 has been used to search for X-ray line emission from Cas A from ions of Si, S, and Fe over the energy band 1.865 to 8 keV. No evidence was obtained for line emission. The upper limits for the Si and S line fluxes are used to establish upper limits on the abundances of these elements. The limit on the Fe line flux is consistent with the strength of the emission feature reported in proportional counter experiments. Questions of nonequilibrium in ionization in Cas A and the effects on X-ray line emission are considered.

Kestenbaum, H. L.↗