Engineering PapersSearch

Engineering topics

Nossen, E. J.

Publications and source records attributed to Nossen, E. J..

One-way Doppler extractor

This paper presents a feasibility analysis, tradeoffs, and implementation for a one-way Doppler extractor system. A Doppler error analysis is discussed which shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared, and a 'Vernier' technique is presented which obtains high Doppler resolution with low-speed logic. Parameter tradeoffs and sensitivities for this Vernier technique are discussed, leading to a hardware design configuration. Also presented is a performance evaluation of the resulting breadboard model that verifies the theoretical performance predictions. The breadboard model contains the circuitry to interface with an S-band transponder, to extract the Doppler and time-interval counts, to compute navigational parameters by means of a microprocessor, and to display the results. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of better than 0.02 hertz for a one-second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

Nossen, E. J.

Doppler extraction with a digital VCO

Digitally controlled oscillator in phased-locked loop may be useful for data communications systems, or may be modified to serve as information extraction component of microwave or optical system for collision avoidance or automatic braking. Instrument is frequency-synthesizing device with output specified precisely by digital number programmed into frequency register.

Starner, E. R.

The Apollo VHF ranging system

As the Apollo program proceeded, redundancy became a requirement for all crew safety functions. One critical period of the Apollo missions was the rendezvous of the Command Module and the Lunar Module. The rendezvous radar provided the critical range, range rate, and angle measurements necessary to complete the rendezvous. Use of a redundant radar for backup was out of the question because of its 80-lb weight. It was, however, found that the voice radios could be adapted to perform the ranging function. Slight modifications of the VHF voice radios and the addition of a ranging interrogator and transponder at a weight of less than 10 lbs total would provide an accuracy of 100-ft rms at several hundred miles. The Apollo VHF ranging system demonstrated that it is feasible to achieve highly accurate range measurements with conventional voice radios.

Nossen, E. J.

One way Doppler Extractor. Volume 2: Digital VCO technique

A feasibility analysis and trade-offs for a one-way Doppler extractor using digital VCO techniques is presented. The method of Doppler measurement involves the use of a digital phase lock loop; once this loop is locked to the incoming signal, the precise frequency and hence the Doppler component can be determined directly from the contents of the digital control register. The only serious error source is due to internally generated noise. Techniques are presented for minimizing this error source and achieving an accuracy of 0.01 Hz in a one second averaging period. A number of digitally controlled oscillators were analyzed from a performance and complexity point of view. The most promising technique uses an arithmetic synthesizer as a digital waveform generator.

Nossen, E. J.

Reduction of quantization error in measurement of frequency

Method reduces quantization errors using new digital circuit. Circuit provides very high resolution (10 to the minus 2nd power to 10 to the minus 3rd power Hz) without high-speed counters. It lends itself to microminaturization and is simple to construct. Unknown frequency is compared to standard frequency by means of zero-crossing coincidence-detecting circuit.

Nossen, E. J.

One way Doppler extractor. Volume 1: Vernier technique

A feasibility analysis, trade-offs, and implementation for a One Way Doppler Extraction system are discussed. A Doppler error analysis shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared and a Vernier technique is developed which obtains high Doppler resolution with low speed logic. Parameter trade-offs and sensitivities for the Vernier technique are analyzed, leading to a hardware design configuration. A detailed design, operation, and performance evaluation of the resulting breadboard model is presented which verifies the theoretical performance predictions. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of less than 0.02 Hertz for a one second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

Blasco, R. W.