Engineering Papers⌕ Search

Engineering topics

Norris, B.

Publications and source records attributed to Norris, B..

Magnetized liner inertial fusion platform development to assess performance scaling with drive parameters

Magnetized liner inertial fusion (MagLIF) experiments have demonstrated fusion-relevant ion temperatures up to 3.1 keV and thermonuclear production of up to 1.1 × 1013 deuterium–deuterium neutrons. This performance was enabled through platform development that provided increases in applied magnetic field, coupled preheat energy, and drive current. Advanced coil designs with internal reinforcement enabled an increase from 10 to 20 T. An improved laser pulse shape, beam smoothing, and thinner laser entrance foils increased preheat energy coupling from less than 1 to 2.3 kJ. A redesign of the final transmission line and load region increased peak load current from 16 to 20 MA. The wider range of input parameters was leveraged to study target performance trends with preheat energy, applied magnetic field, and peak load current. Ion temperature and neutron yield generally followed trends in two-dimensional clean Lasnex calculations. Stagnation performance improved with peak load current when other input parameters were also increased such that convergence was maintained. This dataset suggests that reducing convergence to less than 30 would improve predictability of target performance. Lasnex was used to identify a simulation-optimized scaling path, which suggests 10+ kJ of fusion yield is possible on the Z facility with achievable input parameters. This path also indicates >10 MJ could be generated through volume burn on a future facility with a path to high yield (>200 MJ) using cryogenic dense fuel layers. The newly developed MagLIF platform enables exploration of both this simulation optimized scaling path and a recently developed similarity-scaling path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of an optical imaging system prototype for autonomously monitoring zooplankton in an aquaculture facility

Traditional approaches to biomonitoring in aquatic systems, such as sample collection, sorting, and identification, require significant time and effort, thereby limiting the spatiotemporal resolution of sample collection. Additionally, collection and preservation of samples for subsequent taxonomic identification and enumeration leads to mortality of organisms. Recent advances in technologies that utilize optical imaging and machine learning have provided new opportunities to expedite biomonitoring and lead to significant cost savings. These technologies can be advantageous to scientists or managers that conduct routine biomonitoring to inform operations, as in the case of aquaculture facilities. The Small Aquatic Organism optical imaging system (SAO) is a high-throughput optical imaging and classification prototype system that relies on computer vision and machine learning (Support Vector Machines, or SVMs) to autonomously identify and enumerate aquatic organisms. The SAO provides a more sustainable method of collecting large volumes of data and has the benefit of being used in situ. In this study, we tested the performance of the SAO in providing comparable results to manual zooplankton community monitoring in ten ponds at an aquaculture facility. We performed a side-by-side study comparing the sampling methods of plankton tow nets, where major zooplankton taxonomic classes were manually identified and enumerated, to sampling with the SAO. Vouchered samples were used to develop a training library for the SAO, where classes consisted of water boatman and zooplankton groups: cladocerans, copepod adults, copepod nauplii, and rotifers. SAO imagery was manually classified and compared with predicted results for validation. Accuracy for the SVM classifier of the SAO was 37.4 %. Convolutional Neural Networks (CNN) and Random Forest classifiers were also applied to SAO imagery and image features for comparison. The best CNN model and our Random Forest model had accuracies of 80.4 % and 46.6 % respectively. Challenges faced included the small size of copepod nauplii and rotifers and the limited resolution of the imaging camera, although there are tradeoffs between imaging resolution and the sample processing rate. Furthermore, our comparison shows that advancement in both optical imaging and ML are needed in order for the SAO prototype to yield comparable results to manual community monitoring in an aquaculture facility.

54 ENVIRONMENTAL SCIENCES↗

Speeding up particle track reconstruction using a parallel Kalman filter algorithm

One of the most computationally difficult problems expected for the High-Luminosity Large Hadron Collider (HL-LHC) is determining the trajectory of charged particles during event reconstruction. Algorithms used at the LHC today rely on Kalman filtering, which builds physical trajectories incrementally while incorporating material effects and error estimation. Recognizing the need for faster computational throughput, we have adapted Kalman-filter-based methods for highly parallel, many-core SIMD architectures that are now prevalent in high-performance hardware. In this paper, we discuss the design and performance of the improved tracking algorithm, referred to as mkFit. A key piece of the algorithm is the Matriplex library, containing dedicated code to optimally vectorize operations on small matrices. The physics performance of the mkFit algorithm is comparable to the nominal CMS tracking algorithm when reconstructing tracks from simulated proton-proton collisions within the CMS detector. We study the scaling of the algorithm as a function of the parallel resources utilized and find large speedups both from vectorization and multi-threading. mkFit achieves a speedup of a factor of 6 compared to the nominal algorithm when run in a single-threaded application within the CMS software framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hi-5: A Potential High-Contrast Thermal Near-Infrared Imager for the VLTI

Hi-5 is a high-contrast (or high dynamic range) infrared imager project for the VLTI. Its main goal is to characterize young extra-solar planetary systems and exozodiacal dust around southern main-sequence stars. In this paper, we present an update of the project and key technology pathways to improve the contrast achieved by the VLTI. In particular, we discuss the possibility to use integrated optics, proven in the near-infrared, in the thermal near-infrared (L and M bands, 3-5 μm) and advanced fringe tracking strategies. We also address the strong exoplanet science case (young exoplanets, planet formation, and exozodiacal disks) offered by this wavelength regime as well as other possible science cases such as stellar physics (fundamental parameters and multiplicity) and extragalactic astrophysics (active galactic nuclei and fundamental constants). Synergies and scientific preparation for other potential future instruments such as the Planet Formation Imager are also briefly discussed.

exozodiacal dust↗

The Path Towards High-Contrast Imaging with the VLTI: The Hi-5 Project

The development of high-contrast capabilities has long been recognized as one of the top priorities for the VLTI (Very Large Telescope Interferometer). As of today, the VLTI routinely achieves contrasts of a few 103 in the near-infrared with PIONIER (Precision Integrated-Optics Near-infrared Imaging ExpeRiment) (H band) and GRAVITY (K band). Nulling interferometers in the northern hemisphere and non-redundant aperture masking experiments have, however, demonstrated that contrasts of at least a few 10 (sup -3) are within reach using specific beam combination and data acquisition techniques. In this paper, we explore the possibility to reach similar or higher contrasts on the VLTI. After reviewing the state-of-the-art in high-contrast infrared interferometry, we discuss key features that made the success of other high-contrast interferometric instruments (e.g., integrated optics, nulling, closure phase, and statistical data reduction) and address possible avenues to improve the contrast of the VLTI by at least one order of magnitude. In particular, we discuss the possibility to use integrated optics, proven in the near-infrared, in the thermal near-infrared (L and M bands, 3-5 microns), a sweet spot to image and characterize young extra-solar planetary systems. Finally, we address the science cases of a high-contrast VLTI imaging instrument and focus particularly on exoplanet science (young exoplanets, planet formation, and exozodiacal disks), stellar physics (fundamental parameters and multiplicity), and extragalactic astrophysics (active galactic nuclei and fundamental constants). Synergies and scientific preparation for other potential future instruments such as the Planet Formation Imager are also briefly discussed. This project is called Hi-5 for High-contrast Interferometry up to 5 microns.

PIONIER (H band)↗