Engineering Papers⌕ Search

Engineering topics

Nones, C.

Publications and source records attributed to Nones, C..

At least 55 records · Page 3

An innovative bolometric Cherenkov-light detector for a double beta decay search

Here, we present here an innovative cryogenic light detector capable to measure a few tens of eV signal thanks to the amplification assisted by the Neganov-Luke effect. The thermal signal boost in the presence of an electric field allows us to improve the signal-to-noise ratio reaching a baseline noise of around 20 eV. This device - coupled to an enriched 130TeO 2 bolometer (435 g) - registered 160 eV Cherenkov light signal induced by 2615 keV 208 Tl with a signal to noise ratio about 6:1. Since α particles emitted in decays of natural radionuclides do not produce the Cherenkov radiation, we were then able to achieve an efficient α/γ separation in the region of interest for neutrinoless double beta decay of 130 Te (Q-value is 2527 keV). Specifically, a rejection factor of 99.9% for α particles was obtained with a 98.3% acceptance of β/γ events. The achieved α rejection efficiency is required to reduce the dominant α background in the follow-up of the CUORE experiment (CUPID), a ton-scale bolometric search with particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Cryogenic Underground Observatory for Rare Events: Status and Prospects

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale double beta decay experiment utilizing cryogenic bolometers that is currently being commissioned at the Gran Sasso National Laboratory (LNGS) in Italy. Its primary focus is to search for the neutrino-less double beta decay of 130Te with a projected sensitivity to Majorana neutrino masses near the inverted mass hierarchy region. The detector is composed of 988 5x5x5-cm 3 TeO 2 crystals of natural isotopic composition arranged in 19 towers of 52 crystals each, all housed in a common dilution refrigerator. A single CUORE-like tower, CUORE-0, was assembled and operated as a stand-alone detector for a period of approximately two years. In this report, the results from CUORE-0 and the current status and physics potential of CUORE are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

the Cryogenic Underground Observatory for Rare Events: Status and Prospects

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale double beta decay experiment utilizing cryogenic bolometers that is currently being commissioned at the Gran Sasso National Laboratory (LNGS) in Italy. Its primary focus is to search for the neutrinoless double beta decay of 130Te with a projected sensitivity to Majorana neutrino masses near the inverted mass hierarchy region. The detector is composed of 988 5x5x5-cm 3 TeO 2 crystals of natural isotopic composition arranged in 19 towers of 52 crystals each, all housed in a common dilution refrigerator. A single CUORE-like tower, CUORE-0, was assembled and operated as a stand-alone detector for a period of approximately two years. In this report, the results from CUORE-0 and the current status and physics potential of CUORE are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CUORE cryostat and its bolometric detector

CUORE is a cryogenic detector that will be operated at LNGS to search for neutrinoless double beta decay (0νββ) of 130 Te. The detector installation was completed in summer 2016. Before the installation, several cold runs were done to test the cryogenic system performance. In the last cold run the base temperature of 6.3 mK was reached in stable condition. CUORE-0, a CUORE prototype, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CUORE-0 detector: design, construction and operation

The CUORE experiment will search for neutrinoless double-beta decay of 130 Te with an array of 988 TeO 2 bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this study we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. Finally, in particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First array of enriched Zn$^{82}$Se bolometers to search for double beta decay

The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in 82 Se, the Zn 82 Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn 82 Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-o.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from the CUORE-0 experiment

The CUORE-0 experiment searched for neutrinoless double beta decay in 130 Te using an array of 52 tellurium dioxide crystals, operated as bolometers at a temperature of 10 mK. It took data in the Gran Sasso National Laboratory (Italy) since March 2013 to March 2015. We present the results of a search for neutrinoless double beta decay in 9.8 kg-years 130 Te exposure that allowed us to set the most stringent limit to date on this half-life. The performance of the detector in terms of background and energy resolution is also reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments

CUORE is a 741 kg array of TeO 2 bolometers for the search of neutrinoless double beta decay of 130 Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/(keV·kg·y) will be reached, in five years of data taking CUORE will have a 1σ half life sensitivity of 10 26 y. CUORE-0 is a smaller experiment constructed to test and demonstrate the performances expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis techniques for the evaluation of the neutrinoless double- β decay lifetime in Te 130 with the CUORE-0 detector

We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ( 0 ν β β ) decay in 130 Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive 0 ν β β decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final 0 ν β β search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized 0 ν β β decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the 0 ν β β decay half-life limits previously reported for CUORE-0, T 0 ν 1 / 2 > 2.7 × 10 24 yr , and in combination with the Cuoricino limit, T 0 ν 1 / 2 > 4.0 × 10 24 yr .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Double-beta decay investigation with highly pure enriched $^{82}$Se for the LUCIFER experiment

The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of 82 Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched 82 Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched 82 Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of 232 Th, 238 U and 235 U are respectively: <61, <110 and <74 μBq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the 82 Se allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of 82 Se to 0+1, 2+2 and 2+1 excited states of 82 Kr of 3.4•10 22 , 1.3•10 22 and 1.0•10 22 y, respectively, with a 90 % C.L.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiopure ZnMoO{sub 4} scintillating bolometers for the LUMINEU double-beta experiment

The results of R&D of radiopure zinc molybdate (ZnMoO{sub 4}) based scintillating bolometers for the LUMINEU (Luminescent Underground Molybdenum Investigation for NEUtrino mass and nature) double-beta decay experiment are presented. A dedicated two-stage molybdenum purification technique (sublimation in vacuum and recrystallization from aqueous solutions) and an advanced directional solidification method (the low-thermal-gradient Czochralski technique) were utilized to produce high optical quality large mass (∼1 kg) ZnMoO{sub 4} crystal boules and first {sup 100}Mo (99.5%) enriched Zn{sup 100}MoO{sub 4} crystal scintillator (mass of ∼0.2 kg). Scintillating bolometers based on ZnMoO{sub 4} (≈ 0.33 kg) and Zn{sup 100}MoO{sub 4} (≈ 0.06 kg) scintillation elements and high purity Ge wafers were tested in the EDELWEISS set-up at the Modane Underground Laboratory (France). Long term low temperature tests demonstrate excellent detectors’ performance and effectiveness of the purification and solidification procedures for the achievement of high radiopurity of the material, in particular with a bulk activity of {sup 228}Th and {sup 226}Ra below 4 µBq/kg. The adopted protocol was used to produce for the first time a large volume Zn{sup 100}MoO{sub 4} crystal scintillator (mass of ∼1.4 kg, {sup 100}Mo enrichment is 99.5%) to search for neutrinoless double-beta decay of {sup 100}Mo in the framework of the LUMINEU project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CUORE-0 results and prospects for the CUORE experiment

With 741 kg of TeO{sub 2} crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory for Rare Events) experiment aims at searching for neutrinoless double beta decay of {sup 130}Te with unprecedented sensitivity. Expected to start data taking in 2015, CUORE is currently in an advanced construction phase at LNGS. CUORE projected neutrinoless double beta decay half-life sensitivity is 1.6 × 10{sup 26} y at 1σ (9.5 × 10{sup 25} y at the 90 % confidence level), in five years of live time, corresponding to an upper limit on the effective Majorana mass in the range 40–100 meV (50–130 meV). Further background rejection with auxiliary bolometric detectors could improve CUORE sensitivity and competitiveness of bolometric detectors towards a full analysis of the inverted neutrino mass hierarchy. CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE experiment. It consists of a single CUORE tower (52 TeO{sub 2} bolometers of 750 g each, arranged in a 13 floor structure) constructed strictly following CUORE recipes both for materials and assembly procedures. An experiment its own, CUORE-0 is expected to reach a sensitivity to the ββ(0ν) half-life of {sup 130}Te around 3×10{sup 24} y in one year of live time. We present an update of the data, corresponding to an exposure of 18.1 kg y. An analysis of the background indicates that the CUORE performance goal is satisfied while the sensitivity goal is within reach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The CUORE and CUORE-0 experiments at Gran Sasso

The Cryogenic Underground Observatory for Rare Events (CUORE) is an experiment to search for neutrinoless double beta decay ($0\nu\beta\beta$) in $^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of 988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\% C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to test and demonstrate the performances expected for CUORE, has been assembled and is running. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The next generation of axion helioscopes: The international axion observatory (IAXO)

The International Axion Observatory (IAXO) is a proposed 4 th -generation axion helioscope with the primary physics research goal to search for solar axions via their Primakoff conversion into photons of 1 – 10 keV energies in a strong magnetic field. IAXO will achieve a sensitivity to the axion-photon coupling g aγ down to a few ×10⁻¹² GeV⁻¹ for a wide range of axion masses up to ~ 0.25 eV. This is an improvement over the currently best (3 rd generation) axion helioscope, the CERN Axion Solar Telescope (CAST), of about 5 orders of magnitude in signal strength, corresponding to a factor ~ 20 in the axion photon coupling. IAXO’s sensitivity relies on the construction of a large superconducting 8-coil toroidal magnet of 20 m length optimized for axion research. Each of the eight 60 cm diameter magnet bores is equipped with x-ray optics focusing the signal photons into ~ 0.2 cm² spots that are imaged by very low background x-ray detectors. The magnet will be built into a structure with elevation and azimuth drives that will allow solar tracking for 12 hours each day. This contribution is a summary of our papers [1, 2, 3] and we refer to these for further details.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗