Method and apparatus for supercooling and solidifying substances

An enclosure provides a containerless environment in which a sample specimen is positioned. The specimen is heated in the containerless environment, and the specimen melt is dropped through the tube in which it cools by radiation. The tube is alternatively backfilled with an inert gas whereby the specimen melt cools by both radiation and convection during its free fall. During the free fall, the sample is in a containerless, low-gravity environment which enhances supercooling in the sample and prevents sedimentation and thermal convection influences. The sample continues to supercool until nucleation occurs which is detected by silicon photovoltaic detectors. The sample solidifies after nucleation and becomes completely solid before entering the detachable catcher. The amount of supercooling of the specimen can be measured by knowing the cooling ratio and determining the time for nucleation to occur.

Lacy, L. L.

Containerless high temperature calorimeter apparatus

A calorimeter apparatus for measuring high temperature thermophysical properties of materials is disclosed which includes a containerless heating apparatus in which the specimen is suspended and heated by electron bombardment.

Lacy, L. L.

Containerless materials processing in the laboratory

Drop tube makes possible preparation of exotic materials. The 100 foot tube is oriented precisely vertical to prevent free-falling drop from hitting tube walls. Inert-gas supply, evacuation pumps, viewing ports, and flexibility in choice of melt technique allow precise control and monitoring of solidification.

Lacy, L. L.

Containerless high-temperature calorimeter

Samples are heated by electron bombardment in high-temperature calorimeter that operates from 1,000 to 3,600 C yet consumes less that 100 watts at temperatures less than 2,500 C. Contamination of samples is kept to minimum by suspending them from wire in vacuum chamber. Various sample slopes such as wires, dishs, spheres, rods, or irregular bodies can be accommodated and only about 100 nq of samples are needed for accurate measurements.

Lacy, L. L.

A remote operation quadrupole mass spectrometer using a custom radio-frequency link approach

A commercial quadrupole mass spectrometer (residual gas analyzer, RGA) system has been modified to operate at large separations of its electronics console and sensing head. The methods implemented have made practical applications, as well as operation, of such a system possible for the first time. This advance was stimulated by a need for placing sensors at remote (45 or 60 m) chamber locations for space simulation testing of orbital flight spacecraft. Emphasis is placed on instrument functional requirements and describing the hardware changes and adjustment techniques necessary to assure operation at the extended cable lengths.

Tashbar, P. W.

A modified quadrupole mass spectrometer with custom RF link rods driver for remote operation

A commercial quadrupole residual gas analyzer system has been upgraded for operation at extended cable lengths. Operation inside a vacuum chamber for the standard quadrupole nude head is limited to approximately 2 m from its externally located rf/dc generator because of the detuning of the rf oscillator circuits by the coaxial cable reactance. The advance of long distance remote operation inside a vacuum chamber for distances of 45 and 60 m was made possible without altering the quadrupole's rf/dc generator circuit by employing an rf link to drive the quadrupole rods. Applications of the system have been accomplished for in situ space simulation thermal/vacuum testing of sophisticated payloads.

Tashbar, P. W.