Engineering Papers⌕ Search

Engineering topics

Nisbet, Andrew

Publications and source records attributed to Nisbet, Andrew.

Volumetric-modulated arc therapy (RapidArc) vs. conventional fixed-field intensity-modulated radiotherapy for {sup 18}F-FDG-PET-guided dose escalation in oropharyngeal cancer: A planning study

Fluorine-18-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG-PET)–guided focal dose escalation in oropharyngeal cancer may potentially improve local control. We evaluated the feasibility of this approach using volumetric-modulated arc therapy (RapidArc) and compared these plans with fixed-field intensity-modulated radiotherapy (IMRT) focal dose escalation plans. Materials and methods: An initial study of 20 patients compared RapidArc with fixed-field IMRT using standard dose prescriptions. From this cohort, 10 were included in a dose escalation planning study. Dose escalation was applied to {sup 18}F-FDG-PET–positive regions in the primary tumor at dose levels of 5% (DL1), 10% (DL2), and 15% (DL3) above standard radical dose (65 Gy in 30 fractions). Fixed-field IMRT and double-arc RapidArc plans were generated for each dataset. Dose-volume histograms were used for plan evaluation and comparison. The Paddick conformity index (CI{sub Paddick}) and monitor units (MU) for each plan were recorded and compared. Both IMRT and RapidArc produced clinically acceptable plans and achieved planning objectives for target volumes. Dose conformity was significantly better in the RapidArc plans, with lower CI{sub Paddick} scores in both primary (PTV1) and elective (PTV2) planning target volumes (largest difference in PTV1 at DL3; 0.81 ± 0.03 [RapidArc] vs. 0.77 ± 0.07 [IMRT], p = 0.04). Maximum dose constraints for spinal cord and brainstem were not exceeded in both RapidArc and IMRT plans, but mean doses were higher with RapidArc (by 2.7 ± 1 Gy for spinal cord and 1.9 ± 1 Gy for brainstem). Contralateral parotid mean dose was lower with RapidArc, which was statistically significant at DL1 (29.0 vs. 29.9 Gy, p = 0.01) and DL2 (29.3 vs. 30.3 Gy, p = 0.03). MU were reduced by 39.8–49.2% with RapidArc (largest difference at DL3, 641 ± 94 vs. 1261 ± 118, p < 0.01). {sup 18}F-FDG-PET–guided focal dose escalation in oropharyngeal cancer is feasible with RapidArc. Compared with conventional fixed-field IMRT, RapidArc can achieve better dose conformity, improve contralateral parotid sparing, and uses fewer MU.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cardiac Dose From Tangential Breast Cancer Radiotherapy in the Year 2006

Purpose: To quantify the radiation doses received by the heart and coronary arteries from contemporary tangential breast or chest wall radiotherapy. Methods and Materials: Fifty consecutive patients with left-sided breast cancer and 5 consecutive patients with right-sided breast cancer treated at a large United Kingdom radiotherapy center during the year 2006 were selected. All patients were irradiated with 6- or 8-MV tangential beams to the breast or chest wall. For each dose plan, dose-volume histograms for the heart and left anterior descending (LAD) coronary artery were calculated. For 5 of the left-sided and all 5 right-sided patients, dose-volume histograms for the right and circumflex coronary arteries were also calculated. Detailed spatial assessment of dose to the LAD coronary artery was performed for 3 left-sided patients. Results: For the 50 patients given left-sided irradiation, the average mean (SD) dose was 2.3 (0.7) Gy to the heart and 7.6 (4.5) Gy to the LAD coronary artery, with the distal LAD receiving the highest doses. The right and circumflex coronary arteries received approximately 2 Gy mean dose. Part of the heart received >20 Gy in 22 left-sided patients (44%). For the 5 patients given right-sided irradiation, average mean doses to all cardiac structures were in the range 1.2 to 2 Gy. Conclusions: Heart dose from left-tangential radiotherapy has decreased considerably over the past 40 years, but part of the heart still receives >20 Gy for approximately half of left-sided patients. Cardiac dose for right-sided patients was generally from scattered irradiation alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiac Exposures in Breast Cancer Radiotherapy: 1950s-1990s

Purpose: To estimate the doses to the heart and coronary arteries from common breast cancer radiotherapy (RT) regimens used worldwide from the 1950s to the 1990s. Methods and Materials: Virtual simulation and computed tomography planning were used to reconstruct the megavoltage and electron regimens. Manual planning was used for the orthovoltage and brachytherapy regimens. Several sources of variability associated with the dose estimates were assessed. Results: Breast or chest wall RT resulted in whole heart doses of 0.9-14 Gy for left-sided and of 0.4-6 Gy for right-sided irradiation. Internal mammary chain RT delivered heart doses of 3-17 Gy and 2-10 Gy for left- and right-sided irradiation, respectively. For most regimens, the dose to the left anterior descending coronary artery was greater than the heart dose. Scar boost, supraclavicular fossa, and axillary RT delivered mean cardiac doses of {<=}3 Gy. The greatest source of variability in estimating dose from a given regimen was patient anatomy. Conclusion: For most techniques, the greatest radiation doses were received by the anterior part of the heart and the left anterior descending coronary artery, a common site of atherosclerosis causing myocardial infarction. Irradiation of these structures might have contributed to the excess risk of death from heart disease seen after some past breast cancer RT regimens.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interferometer testbed: Overview and hardware summary

Viewgraphs on an overview and hardware summary for an interferometer testbed are presented. Topics covered include: reference mission and science requirements; science requirements derivation; reference spacecraft design summary; testbed requirements and performance metric; disturbance source and signal; and testbed architecture.

Nisbet, Andrew↗