Engineering Papers⌕ Search

Engineering topics

Nicholson, Andrew D.

Publications and source records attributed to Nicholson, Andrew D..

35 records · Page 2

Classifiers for Dissolution Events in Processing Facility Using Effluents Measurements

Inferring occurrences of dissolutions at a radiochemical processing facility using measurements from an independent monitoring system has potential for verifying operator declarations and compliance with nuclear technology use agreements. We consider the identification of such dissolution events using measurements of radioactive effluents collected at the facility’s off-gas stack. By using simple models for the source term based on radioactive decay-chains and sensor measurements of transported effluents, we formulate a simplified on/off classification problem. There are many available machine learning classification methods applicable to this problem, but they are subject to potential over-fitting. We mitigate this effect by fusing four promising but disparate classifiers: the ensemble of trees, support vector machines, naive Bayes, and k-nearest neighbors. Each classifier is trained to distinguish using effluents measurements between dissolutions of irradiated 237Np/238Pu and Cm/Cf targets from other (or no) radiochemical processing activities. We present Chow and ensemble of trees methods to fuse the classifier outputs to produce a single classification output, and thereby incorporate their diversity of design. We study the performance of these classifiers and fusers using measurements of87Kr,135Xe,138Xe, and138Cs isotopes,and present their training accuracy estimates using individual isotope measurements and all four isotopes taken together.

Rao, Nageswara S.↗

Verification Data Pattern Recognition and Change Detection at the Neutron Instrument Level

As the pressure on International Atomic Energy Agency (IAEA) safeguards resources increases, there is a drive to essentially “do more with less.” New ways of using current verification instrumentation and visualizing the collected data are needed, coupled with maintaining and sustaining the current safeguards instrumentation fleet. This paper explores how to innovate with current safeguards neutron instrumentation using data-driven algorithms at the instrument level. A concept is described for upgrading current neutron counting systems with modern electronics by leveraging electronics developments in other fields (e.g., high-energy physics) to facilitate full list mode data acquisition and, therefore, expand existing analyses to pattern recognition and change detection at the instrument level. The aim is to advance correlated neutron counting by improving the reliability of detecting nuclear material diversion and, at the same time, to improve the sustainability of those systems. It is likely that upgrading existing systems with new hardware and software is more cost-effective than replacing systems with other novel systems that might meet this need. A specific project example is highlighted in which a system was upgraded by retrofitting the standard uranium neutron collar detector with new electronics; as a result, verification data can be analyzed in new ways. A new neutron analysis method, the “List Mode Response Matrix,” has been developed to analyze every pulse train from the detector array and thus enable the verification of spatial information about the assay item for safeguards inspections. This project has improved the reliability of resolving individual fuel pin locations within a given fresh fuel assembly and the percentage of partial defects detected. Herein, the overall concept of upgrading current neutron counting systems is discussed with respect to the potential increase in analysis capabilities. In addition, the details and results of the list mode collar project are discussed.

Worrall, Louise G.↗

Systematic study of variation in radiation data in cluttered environments

There are many challenges to overcome during nuclear nonproliferation measurements, including a wide variety of clutter sources that may be introduced into a scene during acquisition. The ability to understand how the dissimilarity of various objects, or clutter, obscures a detector’s field of view and affects the measured response of the detector improves the input to detection alarm and nuclide identification algorithms. Additionally, having the capability to input clutter variation into radiation transport models would allow for more real-world scenarios to be modeled and understood. Efforts at Oak Ridge National Laboratory have been exploring the ability to determine specific natural background radiation contributions from surroundings, such as buildings, soil, asphalt, and concrete, and use those source terms in large-scale (100 + m) models. The capability to quantify different clutter terms, ranging from humans to large vehicles, allows researchers to inject realistic noise into these models. The work reported herein seeks to explore the effects that clutter introduces to quantify the expected signal variation inherent to both controlled and uncontrolled scenarios, specifically how the introduction of clutter into a scene introduces a variation in signals due to the attenuation of naturally occurring radioactive material distributed within the scene or by introducing non-threatening radioactive materials into the scene. Controlled measurements aim to quantify how different types of clutter of varying size and composition affects the response of a radiation detector. Using results from various controlled tests, the systematic effects of clutter and its effect on radiation readings is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of gamma-ray background outside of the High Flux Isotope Reactor

Static gamma-ray measurements collected between September 2017 and March 2018 in the vicinity of the High Flux Isotope Reactor (HFIR) and the Radiochemical Engineering Development Center (REDC) at Oak Ridge National Laboratory are presented. Temporal events are identified and tracked, including radioactive material transfers, rain events, and 41 Ar emissions. The remaining data is used to determine the average background and its variation. Finally, these results will be used to benchmark Monte Carlo transport models of the HFIR/REDC vicinity and provide training data for material transfer tracking algorithms and data fusion algorithms to determine HFIR operational status under the Multi-Informatics for Nuclear Operations Scenarios program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Understanding and quantifying the systematic effects of clutter within a radiation detection scene

Because of low signal-to-noise ratios, the main difficultly in real-world detection scenarios is distinguishing between benign sources and potentially-threatening radioactive materials. The variability in observed signal during a radiation detection search operation can be contributed to the stochastic nature of the underlying physics and the systematic errors inherent to the detection systems employed. This variability is compounded for dynamic detection scenarios, where objects, referred to as clutter, traverse through the primary detection scene, introducing potential suppressions in the observed signal due to the attenuation of background radiation. This study examines the impact that clutter, namely automobiles such as small utility vehicles, sedans, and trucks, produces on the observed signal in a 2 in. × 4 in. × 16 in. NaI(Tl) detector. The clutter is identified and tracked in the detection scene using a time-synced video camera and a 2-D light distance and ranging contextual sensors. Two experiments were performed on the Oak Ridge National Laboratory reservation: one using a distributed source within the scene to understand the systematics of detecting and analyzing the clutter, and the second experiment mimicking an urban environment with large buildings positioned on either side of a roadway. The experiments exhibited unique results in the amount of signal suppression and variability of the cluttered signal, both demonstrating an observable suppression from the clutter-free background. These results reveal a new potential category of signal noise intrinsic to real-world detection scenarios that should be considered when establishing detection thresholds based on expected values.

Stewart, Ian R.↗

High-Resolution Gamma Spectrometry Data Set for High Burnup Pressurized Water Reactor Used Fuel

Over the past decade, considerable resources have been applied to investigate verification of used nuclear fuel assemblies for international safeguards. The opportunity to expand the available data used to validate these verification techniques was presented in 2016 by the High Burnup Spent Fuel Data Project, which made 25 high-burnup pressurized water reactor used fuel rods available for measurement in the Irradiated Fuels Examination Laboratory at Oak Ridge National Laboratory. With the support of the National Nuclear Security Administration Office of Nonproliferation and Arms Control, a 2017 campaign measured the 25 used fuel rods with a high-resolution gamma spectrometer. A planar high-purity germanium detector was used to provide high-efficiency across an energy range from 60 keV to 3 MeV. Gamma spectra of individual fuel rods were collected in 4.5 mm steps along the entire length of each rod. In addition, spectra were collected on select rods in rotational increments of 30 degrees to provide data on the distribution of fission products along the rod perimeter. The spectra are stored on a controlled-access website for use by others. This paper describes the measurement geometry, used fuel rod characteristics, example spectra, and preliminary analyses performed during the measurement campaign.

Smith, Susan↗

A Methodology for Determining the Concentration of Naturally Occurring Radioactive Materials in an Urban Environment

The detection of radioactive sources in an urban setting is greatly complicated by natural background radiation, which emanates from various materials including roadways, sidewalks, soil, and building exteriors. The method presented and demonstrated here represents an effort to characterize the concentration of naturally occurring radioactive material (NORM) in these types of materials. The location surveyed in this work was the Fort Indiantown Gap Combined Arms Collective Training Facility in Lebanon County, Pennsylvania. Over 70 measurements with a high-purity germanium detector were performed to ascertain the NORM concentrations present in the soil, asphalt, gravel, concrete, and walls found throughout the site. Monte Carlo radiation transport calculations were used to obtain detector responses for these various geometries and materials to convert these measurements into NORM concentration estimates. Lastly, synthetic spectra were simulated using the predicted source terms and compared to actual measurements, showing acceptable agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution Gamma Spectroscopy Measurements of Pressurized Water Reactor Spent Nuclear Fuel Rods

International nuclear safeguards use nondestructive assay techniques to verify declared characteristics of spent nuclear fuel (SNF) assemblies. The declared characteristics usually include the initial enrichment, assembly average burnup, and irradiation history. The primary nondestructive assay tool used by the International Atomic Energy Agency has been the fork detector irradiated fuel measurement system, which uses gross gamma and neutron correlations; however, there have been several research publications within the last decade on the use of high-resolution gamma spectroscopy for the determination of SNF characteristics. References [1]–[6] are published journal articles on this subject from 2006–2016. This report describes measurements of 25 individual SNF rods using high-resolution gamma spectroscopy. Details of the measurement geometry, measurement settings, and rod characteristics are documented. These spectra are intended for the validation of simulation codes that calculate SNF inventory and source term characteristics. The spectrum archive is available to evaluate future spectrum analysis methods. The archive contains full axial scan spectra of each SNF rod. This allows more detailed comparison between simulation and nondestructive analysis than is possible on assemblies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Urban Scenarios & Experiments: Fort Indiantown Gap Data Collections Summary and Analysis

This report summarizes experimental radiation detector, contextual sensor, weather, and global positioning system (GPS) data collected to inform and validate a comprehensive, operational radiation transport modeling framework to evaluate radiation detector system and algorithm performance. This framework will be used to study the influence of systematic effects (such as geometry, background activity, background variability, environmental shielding, etc.) on detector responses and algorithm performance using synthetic time series data. This work consists of performing data collection campaigns at a canonical, controlled environment for complete radiological characterization to help construct and benchmark a high-fidelity model with quantified system geometries, detector response functions, and source terms for background and threat objects. This data also provides an archival, benchmark dataset that can be used by the radiation detection community. The data reported here spans four data collection campaigns conducted between May 2015 and September 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OR14-V-Uncertainty-PD2La Uncertainty Quantification for Nuclear Safeguards and Nondestructive Assay Final Report

The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically provide error bars and also partition total uncertainty into “random” and “systematic” components so that, for example, an error bar can be developed for the total mass estimate in multiple items. Uncertainty Quantification (UQ) for NDA has always been important, but it is recognized that greater rigor is needed and achievable using modern statistical methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

OR14-V-Uncertainty-PD2La Uncertainty Quantification Workshop Report

The Uncertainty Quantification (UQ) research team held the Uncertainty Quantification for Nondestructive Assay Workshop as part of the Advances in Nuclear Nonproliferation Technology & Policy Conference held in Santa Fe, New Mexico, on September 28–30, 2016. The workshop had 14 speakers, each of whom submitted a paper for publication in the conference proceedings. They gave lectures in the mornings and participated in discussions in the afternoons. Forty-three people from the national laboratories, industry, and academia attended the workshop. Their research interests ranged from uncertainties in nuclear data to uncertainties in human reliability.

97 MATHEMATICS AND COMPUTING↗

Initial Modeling of Urban Search Measurements

Detection of illicit nuclear materials in urban environments is difficult due to the large amount of background radiation from naturally occurring radioactive materials (NORM) in the roadways and buildings. Mobile searches suffer from low count rates, so the detection algorithms must be carefully balanced between missing real sources and reporting too many false alarms. The Modeling Urban Scenarios and Experiments (MUSE) project aims to create a virtual testbed for simulation of radiation detection to predict realistic background and threat source detection events so that detection algorithms can be better optimized to find illicit sources. The MUSE project is a collaboration of Oak Ridge National Laboratory (ORNL), Lawrence Berkeley National Laboratory (LBNL), and the Remote Sensing Laboratory (RSL). The project also works with staff at Lawrence Livermore National Laboratory (LLNL) to support the development of the Optimization Planning Tool for Urban Search (OPTUS) software package. The first step in creating a virtual testbed is to determine the level of detail required in the models to match actual measurements. Several measurement campaigns were conducted in 2015 and 2016 at the Fort Indiantown Gap (FTIG) Combined Arms Collective Traming Facility (CACTF). This facility contains a representative urban environment, with a dozen buildings and several streets. Detectors commonly used in search operations - 2 in x 4 in x 16 in NaI(Tl) - were used to measure count rates from background and sources. Measurements with a shielded high-purity germanium detector of the roadways, sidewalks, and building walls were made to determine the concentration of NORM that makes up the bulk of the background radiation. This paper shows some comparisons of modeling simulations to measurements taken during the OPTUS-3 campaign in November 2015. Measurements with and without an 81 {mu}Ci cesium source were made at several points along the center line of the main road. Initial results show good agreement between the measured and simulated spectra above 300 keV. Additional studies to determine the causes of mismatch below 300 keV have been started and will also be discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of NORM in an Urban Environment using HPGe Measurements and MCNP6 Simulations

This work is part of a larger project aimed at producing an operationally relevant, validated simulation environment that can be used as a 'virtual testbed' for counterterrorism and counterproliferation efforts. Examples of such efforts include searches for illicit radiation sources before and during large special events, such as the presidential nominating conventions, inaugurations, and large sporting events. Once validated by laboratory and field measurements, this testbed can be used to test and validate algorithms and detector systems designed for various search missions in an urban environment. The detection of radioactive sources in a city is greatly complicated by natural background radiation, which emanates from various materials common to an urban environment, such as roadways, sidewalks, and building exteriors. The methods and results offered here represent the conclusion of an effort to characterize the concentration of naturally occurring radioactive material (NORM) in various elements in a controlled, but representative, urban environment. Some of the methods discussed in previous work will be briefly reiterated here, but more detail can be found in the preceding work. The location chosen for this effort was a Military Operations on Urban Terrain (MOUT) environment at the Fort Indiantown Gap (FTIG) National Guard training facility in Pennsylvania. This site was chosen because it replicates a small town where traffic and pedestrian access could be easily controlled, as to not interfere with the background measurements. This endeavor involved over 70 measurements using a high-purity germanium (HPGe) detector designed to ascertain the NORM concentrations in the soil, asphalt roads, gravel lots, concrete intersections, sidewalks, foundations, and walls found throughout the site. The NORM concentrations determined from this work will be incorporated into a large-scale simulation that can be used to investigate various search techniques and algorithms, detector types and setups, and to produce representative synthetic data for future work.

07 ISOTOPE AND RADIATION SOURCES↗

NORM Concentration Determination in Common Materials in an Urban Environment

The United States government performs searches for illicit radiation sources before and during large special events, such as State of the Union addresses, presidential inaugurations, or the recent papal visit. Clear detection of sources is difficult due to natural background radiation, which can vary greatly throughout a given search area. Background radiation is mostly a function of the materials used in roadways, sidewalks, and building exteriors. A team of scientists from Oak Ridge National Laboratory (ORNL), Lawrence Livermore National Laboratory (LLNL), the Remote Sensing Laboratory (RSL), and Lawrence Berkeley National Laboratory (LBNL) is exploring the nature and variability of background count rates in order to improve the performance of searches in urban areas. A series of background measurements have been and will continue to be taken at a Military Operations on Urban Terrain (MOUT) environment at the Fort Indiantown Gap (FTIG) National Guard training facility in Pennsylvania. This site replicates a small town with asphalt roads, concrete intersections, buildings, sidewalks, curbs, and gravel parking areas. Unlike an actual urban area, traffic and pedestrian access can be easily controlled to avoid interference with measurements. This paper documents the efforts focused on characterizing the various concentrations of radioactive material found in these materials at the site. The NORM concentrations determined from this work will be incorporated in to a large-scale simulation (a 'virtual test-bed') that can be used to investigate various search techniques and algorithms, detector suite configurations, and to produce representative synthetic data for future work. A combination of measurement and simulation was used to determine the concentration of {sup 40}K and the radioactive nuclides in the uranium series and the thorium series in several materials at the FTIG MOUT site. The predicted concentrations are consistent with other published results, and they matched favorably with synthetic data generated with MCNP6 models using the determined NORM concentrations and estimates of the FTIG environment as described by available construction plans and using standard material assumptions. Future measurements will incorporate lessons learned from this study. More measurements will be made of the concrete intersections at the site. The methodology explained in this report will also be carried out on building materials in an effort to characterize NORM concentrations in these background sources. Other modeling and simulation work that should be conducted includes a robust sensitivity analysis in which the effects of small changes to the model (and measurement) system can be characterized to help bound the uncertainty on the final NORM concentration predictions. (authors)

54 ENVIRONMENTAL SCIENCES↗

Enrichment Meter Dataset from High-Resolution Gamma Spectroscopy Measurements of U3O8 Enrichment Standards and UF6 Cylinder Wall Equivalents

The Enrichment Meter Principle (EMP) is the basis for a commonly used standard test method for the non-destructive assay of 235 U enrichment in bulk compounds [1]. The technique involves determining the net count rate in the direct 186 keV peak using medium or high energy gamma-ray spectrometry in a fixed geometry. With suitable correction for wall attenuation, compound type, rate loss (live time), and peaked background (if significant), the atom fraction of 235 U may be obtained from the counting rate from a linear relationship through the origin. The widespread use of this method for field verification of enrichment [2,3] together with the fact that the response function rests on fundamental physics considerations (i.e., is not represented by a convenient but arbitrary form) makes it an interesting example of uncertainty quantification, one in which one can expect a valid measurement model can be applied. When applied using NaI(Tl) and region of interest analysis, the technique is susceptible to both interference error and bias [2-4]. When implemented using high-resolution gamma-ray spectroscopy, the spectrum interpretation is considerable simplified and more robust [5]. However, a practical challenge to studying the uncertainty budget of the EMP method (for example, to test linearity, extract wall corrections and so forth using modern methods) is the availability of quality experimental data that can be referenced and shared. To fill this gap, the research team undertook an experimental campaign [6]. A measurement campaign was conducted to produce high-resolution gamma spectroscopy enrichment meter data comparable to UF 6 cylinder measurements. The purpose of this report is to provide both an introduction to and quality assurance (QA) of the raw data produced. This report is intended for the analyst or researcher who uses the raw data. Unfortunately, the raw data (i.e., the spectra files) are too voluminous to include in this report but can be requested from Steven Croft of the Safeguards & Security Technology Group (scroft@ornl.gov 865-241-2834). The complete processed data are tabulated in Appendix A. The analysis techniques used to produce the QA data presented in this report [e.g., three regions-ofinterest (ROI) peak extraction and batch analysis processes] are not the most sophisticated techniques available; analysts are encouraged to reanalyze the raw data using more sensitive techniques and to improve upon the results presented here. With that being said, the analysis techniques used here are more than adequate to present and inspect the quality of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic Assessment of Neutron and Gamma Backgrounds Relevant to Operational Modeling and Detection Technology Implementation

This report summarizes the findings of a two year effort to systematically assess neutron and gamma backgrounds relevant to operational modeling and detection technology implementation. The first year effort focused on reviewing the origins of background sources and their impact on measured rates in operational scenarios of interest. The second year has focused on the assessment of detector and algorithm performance as they pertain to operational requirements against the various background sources and background levels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗