Engineering Papers⌕ Search

Engineering topics

Nguyen, Tim

Publications and source records attributed to Nguyen, Tim.

Advanced Monitoring and Control in the ANL METL Facility Using an Engineering Digital Twin

The potential benefits of using an engineering digital twin to achieve greater autonomy for monitoring and control functions in advanced reactors was investigated for the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The METL sodium purification system served as a representative system as it requires significant human in-the-loop interaction to accomplish its design function. The objective was to demonstrate how real-time operation could be automated while preserving oversight of the operator for ensuring that the system design functions are met. A digital twin model of the purification system was developed for both the cold trap purification loop and plugging meter diagnostic loop using information from the METL piping and instrumentation diagram (P&ID). Automated monitoring and diagnosis of component degradation in the METL facility was demonstrated in tests using the PRO-AID health monitoring software with the digital twin model incorporated in the library of components. Component failures were introduced and were successfully diagnosed in real time. These tests serve to demonstrate an advanced monitoring capability able to differentiate sensor degradation from component degradation, to generate a rank ordering of probabilities of different failure mechanisms that serves to circumvent the false alarm problem with current anomaly detection methods, and how facility monitoring can be transformed from anomaly detection to identification of a specific fault. Automated control of the purification system was demonstrated through simulations that exercised a model predictive controller designed using the digital twin model. Results of these simulations compared favorably with experimental data showing very good reference tracking response with negligible overshoot. In conclusion, these pilot tests and simulations successfully demonstrated the use of a digital twin for improved automation of monitoring and control. It was shown how the digital twin enables switching between control modes from cold trap operation where impurities are removed to plugging meter operation where impurity concentrations are measured.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cost Benefit Analyses through Integrated Online Monitoring and Diagnostics (Final Report)

The objective of this research is to improve the economic competitiveness of advanced reactors through the optimization of cost and plant performance, which can be achieved by coupling intelligent online monitoring with asset management decision-making. As advanced reactors are early in the development life-cycle, online monitoring systems and associated sensor networks can be incorporated directly into the design without constraints related to retrofitting and system upgrades

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Description of Sensor Assignment Optimization Method as Deployed on a Multi-Node Cluster

Data analytic methods are being developed to address the problem of how to assign a sensor set in a nuclear facility such that a requisite level of process monitoring capability is realized and that the sensor set is sufficiently rich to determine the status of the individual sensors with respect to need for calibration. There is an awareness in the nuclear industry that data analytics combined with rich sensor sets represent a means to improve operations and reduce costs. In the industry the calibration problem has been previously approached as an empirical data-driven problem with several methods having been developed. However, the experience of the utilities over the past ten years with these methods indicates that the absence of physics-based information renders the data-driven approach less reliable. Complicating factors such as the inherent variability of operation (both equipment alignment and operating condition) can confound a pure data-driven approach while there are no rigorous guidelines for determining what constitutes an adequate sensor set. The solution under development to overcome these shortcomings supplements the data analytic method with process information in a so-called process-constrained data-analytic approach. Simple balance equations are written for generic components (e.g., mechanical pump, valve, and heat exchanger). These do not require a priori knowledge of process parameters, such as heat transfer coefficients or friction factors. All that is needed on the part of the utility user is to identify the components and how they are connected. This report describes the development of a parallel computing capability for determining the optimal sensor set. The optimal sensor set problem suffers from the curse of dimensionality. Computation time increases exponentially as the size of the system grows. To overcome this difficulty a pre-conditioner algorithm is developed to find an approximate solution close the actual solution. This serves as a seed for the full-blown algorithm and acts to constrain the space that must searched. The optimization algorithms are described and the implementation on a parallel computing platform is described. The application of the method to a use case we are solving in collaboration with our utility partner served to illustrate how the default sensor set in a nuclear plant may not provide sufficient coverage to infer sensor calibration status.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗