Development and testing of the IAEA universal non-destructive assay data acquisition platform (UNAP)
Abstract Not Provided
Engineering topics
Publications and source records attributed to Newell, Matthew R.
Abstract Not Provided
Abstract Not Provided
Safeguarding natural uranium as it enters the fuel cycle has become a priority for the safeguards community in recent years. Uranyl nitrate is a material of interest in this endeavor because it is normally a step in the process from converting uranium ores to more concentrated forms like UO{sub 2} and U{sub 3}O{sub 8}. This paper will detail the improvements and design optimizations made for a uranyl nitrate neutron detector. The original design of the detector was based on standard neutron counter designs and featured 2 rings of He-3 tubes fully moderated and shielded from background. Several areas for enhancement were identified after months of testing in three different locations. An operating uranyl nitrate facility was included as one of the test locations. Three significant upgrades to the counter addressed in the redesign were: real time background detection, counter reliability improvements, and optimization of the detector design for the detection of neutrons emitted by the uranyl nitrate flowing through the monitored process pipe. The optimized detector design includes significant electronics upgrades, the ability to detect neutrons (background and signal) with 36 degree spatial resolution around the process pipe for signal and 45 degree spatial resolution for background, inner and outer rings of He-3 tubes for real time background corrections, and notably more reliable cabling. Monte Carlo N-Particle (MCNP) modeling was used to optimize the signal (neutrons from uranyl nitrate in the monitored process pipe) to noise (background neutrons from all sources) ratio of the inner ring of He-3 tubes. Additionally, MCNP modeling maximized noise to signal on the outer ring of He-3 tubes. Details of the detector optimization as well as all the additional detector enhancements will be discussed. The neutron counter will be field tested on the Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory (ORNL).
Accessing special nuclear material (SNM) standards for the calibration of and training on nondestructive assay (NDA) instruments has become increasingly difficult in light of enhanced safeguards and security regulations. Limited or nonexistent access to SNM has affected neutron based NDA techniques more than gamma ray techniques because the effects of multiplication require a range of masses to accurately measure the detector response. Neutron based NDA techniques can also be greatly affected by the matrix and impurity characteristics of the item. The safeguards community has been developing techniques for calibrating instrumentation and training personnel with dwindling numbers of SNM standards. Monte Carlo methods have become increasingly important for design and calibration of instrumentation. Monte Carlo techniques have the ability to accurately predict the detector response for passive techniques. The Monte Carlo results are usually benchmarked to neutron source measurements such as californium. For active techniques, the modeling becomes more difficult because of the interaction of the interrogation source with the detector and nuclear material; and the results cannot be simply benchmarked with neutron sources. A Monte Carlo calculated calibration curve for a training course in Indonesia of material test reactor (MTR) fuel elements assayed with an active well coincidence counter (AWCC) will be presented as an example. Performing training activities with reduced amounts of nuclear material makes it difficult to demonstrate how the multiplication and matrix properties of the item affects the detector response and limits the knowledge that can be obtained with hands-on training. A neutron pulse simulator (NPS) has been developed that can produce a pulse stream representative of a real pulse stream output from a detector measuring SNM. The NPS has been used by the International Atomic Energy Agency (IAEA) for detector testing and training applications at the Agency due to the lack of appropriate SNM standards. This paper will address the effect of reduced access to SNM for calibration and training of neutron NDA applications along with the advantages and disadvantages of some solutions that do not use standards, such as the Monte Carlo techniques and the NPS.
A portable multiplicity counter has signal input circuitry, processing circuitry and a user/computer interface disposed in a housing. The processing circuitry, which can comprise a microcontroller integrated circuit operably coupled to shift register circuitry implemented in a field programmable gate array, is configured to be operable via the user/computer interface to count input signal pluses receivable at said signal input circuitry and record time correlations thereof in a total counting mode, coincidence counting mode and/or a multiplicity counting mode. The user/computer interface can be for example an LCD display/keypad and/or a USB interface. The counter can include a battery pack for powering the counter and low/high voltage power supplies for biasing external detectors so that the counter can be configured as a hand-held device for counting neutron events.