Engineering Papers⌕ Search

Engineering topics

Neudecker, Denise

Publications and source records attributed to Neudecker, Denise.

At least 145 records · Page 8

ARIADNE – a program estimating covariances in detail for neutron experiments

The python program ARIADNE is a tool developed for evaluators to estimate detailed uncertainties and covariances for experimental data in a consistent and efficient manner. Currently, it is designed to aid in the uncertainty quantification of prompt fission neutron spectra, and was employed to estimate experimental covariances for CIELO and ENDF/B-VIII.0 evaluations. It provides a streamlined way to estimate detailed covariances by (1) implementing uncertainty quantification algorithms specific to the observables, (2) defining input quantities for typically encountered uncertainty sources and correlation shapes, and (3) automatically generating plots of data, uncertainties and correlations, GND formatted XML and plain text output files. Covariances of the same and between different datasets can be estimated, and tools are provided to assemble a database of experimental data and covariances for an evaluation based on ARIADNE outputs. The underlying IPython notebook files can be easily stored, including all assumptions on uncertainties, leading to more reproducible inputs for nuclear data evaluations. Here, the key inputs and outputs are shown along with a representative example for the current version of ARIADNE to illustrate its usability and to open a discussion on how it could address further needs of the nuclear data evaluation community.

97 MATHEMATICS AND COMPUTING↗

Template for estimating uncertainties of measured neutron-induced fission cross-sections

A template for estimating uncertainties (unc.) of measured neutron-induced fission, (n,f), cross-sections (cs) is presented. This preliminary template not only lists all expected unc. sources but also supplies ranges of unc., estimates for correlations between unc. of the same and different experiments which can be used if the information is nonexistent. If this template is applied systematically when estimating experimental covariances for an evaluation, it may help in pinpointing missing unc. for individual datasets, identifying unreasonably low unc., and estimating correlations between different experimental datasets. Thus, a detailed unc. estimate – usually, a time-intensive procedure – can be undertaken more consistently and efficiently. As an example, it is shown that unc. and correlations of 239 Pu(n,f) by Merla et al. [Proceedings of the Conference on Nuclear Data for Science and Technology 1991 Jülich (Springer-Verlag, Berlin, 1992) pp. 510–513], which are questionably low in the GMA database underlying the neutron cs standards evaluations, are distinctly larger at 14.7 MeV and more strongly correlated if this template is used for reestimating the associated covariances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utilization of MCNP ® 6 implicit-capture simulations for quantification of systematic uncertainties from experimental environments

In this study, the high statistical precision that can be achieved using modern data collection techniques implies that systematic uncertainties that were ignored or not considered for past experiments must now be explored. The folding of Monte Carlo simulations into experimental data analysis, which is becoming common practice, requires an estimate of the systematic uncertainty present in the experimental result from uncertainties in the library of cross sections used during the simulation, but this source of uncertainty is typically not quantified. Here we describe a method to estimate this systematic uncertainty by varying the cross sections used during simulation runtime. As opposed carrying out hundreds of sequential analog Monte Carlo simulations, this task was accomplished through a post-processing calculation of output from a single simulation that was run using the implicit-capture formalism available with MCNP ® 6.2 and the PTRAC output format.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Release of ENDF/B-VIII.0-Based ACE Data Files

In February 2018, the National Nuclear Data Center released ENDF/B-VIII.0 in the standard Evaluated Nuclear Data Format (ENDF). This represents the advances made in nuclear data since the release of ENDF/B-VII.1 in 2011.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Information Files of 238 U(n,f)/ 235 U(n,f) NIFFTE fissionTPC Cross-sections for the Neutron Data Standards Project

This report documents input files, output files and underlying assumptions for an uncertainty estimate for nuclear data evaluations purposes of the normalized 238 U/ 235 U neutron-induced fission cross-section ratios, 238 U(n,f)/ 235 U(n,f), measured by the NIFFTE fission Time Projection Chamber (fissionTPC). This uncertainty estimate and the resulting files were based on information provided by fissionTPC experimentalists, R.J.Casperson, N.S. Bowden, L. Snyder and K.T. Schmitt, and an EXFOR file compiled by N. Otuka. These files were generated for the Neutron Data Standards project coordinated by the IAEA in order to simplify the incorporation of 238 U(n,f)/ 235 U(n,f) fissionTPC data into the standards database.

238 U(n,f)/ 235 U(n,f)↗

Evaluations of Energy Spectra of Neutrons Emitted Promptly in Neutron-induced Fission of 235 U and 239 Pu

The energy spectra of neutrons emitted promptly in the neutron-induced fission reactions of 235 U and 239 Pu were re-evaluated for ENDF/B-VIII.0. The evaluations presented here are based on a careful modeling of all relevant physics processes, an extensive analysis of experimental data and a detailed quantification of pertinent uncertainties. Energy spectra of neutrons emitted in up to fourth chance fission are considered and both compound and pre-equilibrium processes are included. Also, important nuclear model parameters, such as the average total kinetic energy of the fission fragments and the multiple chance fission probabilities, and their uncertainties are estimated based on experimental knowledge, model information and evaluated data. In addition to experimental information already available for ENDF/B-VII.1, these new evaluations make use of recently published experimental data either of high precision or spanning a broad incident energy range, information on legacy measurements explaining discrepancies and recently measured data of the average total kinetic energy as a function of incident neutron energy. The resulting evaluated data and covariances agree well with the experimental database used for the evaluation. However, the evaluated spectra are softer than the 235 U and 239 Pu ENDF/B-VII.1, JENDL-4.0 and JEFF-3.2 evaluations for incident neutron energies E inc ≤ 1.5 MeV and E inc ≤ 5 MeV, respectively. For E inc > 5 MeV, the evaluated spectra show structures due to the improved modeling which are not present in ENDF/B-VII.1 and JEFF-3.2 but can be observed in JENDL-4.0 evaluations. Part of these new evaluations were adopted for ENDF/B-VIII.0, while the ENDF/B-VII.1 239 Pu PFNS was retained for E inc ≤ 5 MeV awaiting more conclusive experimental evidence.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Prompt Fission Neutron Spectrum of 235 U(n,f) below 2.5 MeV for Incident Neutrons from 0.7 to 20 MeV

New prompt fission neutron spectrum measurements are reported for 235 U(n,f) reactions induced by neutrons with energies from 0.7 to 20 MeV. These measurements cover outgoing neutron energies from 2.5 MeV down to 10 keV, using an array of 6 Li-glass scintillators for neutron detection and a double time-of-flight technique. The neutrons were produced at the Weapons Neutron Research facility of the Los Alamos Neutron Science Center. A detailed MCNP ® model of the experimental equipment and the surrounding room was used to interpret the experimental results. Backgrounds were measured in situ, making use of the time-dependent singles rates of the various detectors with asynchronous readout from waveform digitizers. The results presented here have been included in a re-evaluation of the fission neutron spectra for this fissioning system, a description of which is presented elsewhere in this issue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the 235 U prompt fission neutron spectrum including a detailed analysis of experimental data and improved model information

We present an evaluation of the 235 U prompt fission neutron spectrum (PFNS) induced by thermal to 20-MeV neutrons. Experimental data and associated covariances were analyzed in detail. The incident energy dependence of the PFNS was modeled with an extended Los Alamos model combined with the Hauser-Feshbach and the exciton models. These models describe prompt fission, pre-fission compound nucleus and pre-equilibrium neutron emissions. The evaluated PFNS agree well with the experimental data included in this evaluation, preliminary data of the LANL and LLNL Chi-Nu measurement and recent evaluations by Capote et al. and Rising et al. However, they are softer than the ENDF/B-VII.1 (VII.1) and JENDL-4.0 PFNS for incident neutron energies up to 2 MeV. Simulated effective multiplication factors k eff of the Godiva and Flattop-25 critical assemblies are further from the measured k eff if the current data are used within VII.1 compared to using only VII.1 data. However, if this work is used with ENDF/B-VIII.0β2 data, simulated values of k eff agree well with the measured ones.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

General Guidelines on Criteria for Adoption or Rejection of Evaluated Libraries and Data by the Nuclear Data Team

This memo contains general guidelines on what documentation and tools need to be in place as well as format and data testing requirements such that evaluated nuclear data sets or entire libraries can be adopted by the nuclear data team. Additional requirements beyond this memo might apply for specific nuclear data observables. These guidelines were established based on discussions between J.L. Conlin, M.G. Gray, A.P. McCartney, D. Neudecker, D.K. Parsons and M.C. White.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The Prompt Fission Neutron Spectrum of 235U for Einc 0.7-5.0 MeV

The Chi-Nu experiment aims to accurately measure the prompt fission neutron spectrum (PFNS) for the major actinides. At the Los Alamos Neutron Science Center (LANSCE), fission can be induced using the white neutron source. Using a two arm time of flight (T.O.F) technique; Chi-Nu presents a preliminary result of the low energy component of the 235U PFNS measured using an array of 22-Lithium glass scintillators.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluating the 239 Pu prompt fission neutron spectrum induced by thermal to 30 MeV neutrons

We present a new evaluation of the 239 Pu prompt fission neutron spectrum (PFNS) induced by thermal to 30 MeV neutrons. Compared to the ENDF/B-VII.1 evaluation, this one includes recently published experimental data as well as an improved and extended model description to predict PFNS. For instance, the pre-equilibrium neutron emission component to the PFNS is considered and the incident energy dependence of model parameters is parametrized more realistically. Experimental and model parameter uncertainties and covariances are estimated in detail. Also, evaluated covariances are provided between all PFNS at different incident neutron energies. In conclusion, selected evaluation results and first benchmark calculations using this evaluation are briefly discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗