Engineering Papers⌕ Search

Engineering topics

Nelson, R. O.

Publications and source records attributed to Nelson, R. O..

At least 19 records

γ-ray measurements in fast-neutron-induced reactions on 203 Tl

Fast-neutron-induced reactions can be used to characterize reaction mechanisms, investigate nuclear structure, and impose constraints on nuclear models. Because of the difficulty in predicting such effects, experimental data are important to constrain models. Thallium isotopes located close to the doubly magic Pb 208 nucleus are important for comparison with shell-model calculations. Study the population of excited states in Tl 203 and lighter isotopes in such reactions. Our methods are as follows. γ -ray cross sections were measured. The data were taken by using the Germanium Array for Neutron-Induced Excitations spectrometer. The pulsed neutron source of the Los Alamos Neutron Science Center's Weapons Neutron Research facility provided neutrons in the energy range from 1 to 300 MeV. The time-of-flight technique was used to determine the incident neutron energies. Cross sections for emission of several γ rays in 20 reaction channels were determined. Candidates for the intruder 9 / 2 - state in Tl 203 , from the odd proton in the h 9 / 2 orbital, and the first 5 + states in Tl 202 , 204 , from admixture of configurations, were identified. The excitation energy of the candidate 9 / 2 - , π h 9 / 2 state is in good agreement with the theoretical prediction from a semi-empirical weak-coupling model and its half-life is in the range of tens of nanoseconds. The feeding of a previously known isomer in Tl 202 exhibits similarities with the feeding of other isomers in this mass region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron inelastic scattering measurements on Xe 136 at E n = 0.7 to 100 MeV

Experiments searching for neutrinoless double ${\beta}$ decay ($0{\nu}{\beta}{\beta}$) require precise energy calibration and extremely low backgrounds. One of the most popular isotopes for $0{\nu}{\beta}{\beta}$ experiments is $^{136}\mathrm{Xe}$. In support of these experiments, the neutron inelastic scattering properties of this isotope have been measured at the GErmanium Array for Neutron Induced Excitations (GEANIE) at the Los Alamos Neutron Science Center. Time-of-flight techniques are utilized with high-purity germanium detectors to search for inelastic scattering ${\gamma}$ rays for neutron energies between 0.7 and 100 MeV. Limits are set on production of yet-unobserved ${\gamma}$ rays in the energy range critical for $0{\nu}{\beta}{\beta}$ studies, and measurements are made of multiple ${\gamma}$-ray production cross sections. In particular, we have measured the production of the 1313 keV ${\gamma}$ ray, which comes from the transition of the first-excited to ground state of $^{136}\mathrm{Xe}$. This neutron-induced ${\gamma}$ line may be useful for a novel energy calibration technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MeV bremsstrahlung X rays from intense laser interaction with solid foils

Laser-based compact MeV X-ray sources are useful for a variety of applications such as radiography and active interrogation of nuclear materials. MeV X rays are typically generated by impinging the intense laser onto ~mm-thick high-Z foil. Here, we have characterized such a MeV X-ray source from 120 TW (80 J, 650 fs) laser interaction with a 1 mm-thick tantalum foil. Our measurements show X-ray temperature of 2.5 MeV, flux of 3 × 10 12 photons/sr/shot, beam divergence of ~0.1 sr, conversion efficiency of ~1%, that is, ~1 J of MeV X rays out of 80 J incident laser, and source size of 80 m. Our measurement also shows that MeV X-ray yield and temperature is largely insensitive to nanosecond laser contrasts up to 10 -5 . Also, preliminary measurements of similar MeV X-ray source using a double-foil scheme, where the laser-driven hot electrons from a thin foil undergoing relativistic transparency impinging onto a second high-Z converter foil separated by 50–400 m, show MeV X-ray yield more than an order of magnitude lower compared with the single-foil results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gallium nitride (GaN) devices as a platform technology for radiation hard inertial confinement fusion diagnostics

Inertial Confinement Fusion (ICF) is undergoing more detailed research to increase neutron yield and will require high resolution imaging near the target. Neutron damage to diagnostics remains a serious issue in understanding and achieving ICF. We have demonstrated that Gallium Nitride (GaN) optoelectronic devices have exceptional neutron radiation hardness, by systematic testing of neutron radiation effects in GaN devices and materials with elevated neutron fluence levels and a broad neutron energy spectrum. During the 2013-2017 run cycles at Los Alamos Neutron Science Center (LANSCE), we irradiated various GaN materials and devices with fast and thermal plus resonance neutrons at several beamlines. This work presents a radiation hardness study for Aluminum Gallium Nitride and Gallium Nitride (AlGaN/GaN) deep UV LEDs irradiated at the LANSCE 4FP60R beamline. The fluence level was up to 2.4 × 10 13 neutrons/cm 2 for neutrons with energies greater than 0.1 MeV. The device performance was monitored in real time. After three years of irradiation studies, we found that the GaN devices maintained operation in the forward active region. The current and voltage relation (I-V curves) varied insignificantly in the linear region. Finally, our results demonstrate the radiation hardness needed for laser fusion diagnostics at least up to 10 17 neutron yield per shot, if the diagnostics is placed 1 m away from the target, where the neutron fluence per shot is approximately 8 × 10 11 n/cm 2 . The GaN devices can operate for multiple shots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of C 7 LYC scintillators in fast neutron spectroscopy

Here, the capabilities of 7 Li-enriched Cs 2 7 LiYCl 6 (C 7 LYC) scintillation detectors for fast neutron spectroscopy are explored in benchmark experiments that exploit its excellent pulse-shape discrimination between neutrons and γ rays, and its unprecedented ≈10% energy resolution for fast neutrons in the few MeV range, obtained through the 35 Cl(n,p) reaction. Energy- and angle-resolved elastic and inelastic neutron scattering cross-section measurements of 56 Fe(n,n’) were performed at Los Alamos National Laboratory with a pulsed white neutron source and an array of 1" x 1" C 7 LYC crystals. The results convincingly establish the utility of this dual n/γ scintillator for fast neutron spectroscopy. Intrinsic efficiency measurements of both 1" x 1" and the first ever 3" x 3" C 7 LYC crystal have been initiated, using mono-energetic fast neutron beams at UMass Lowell generated via the 7 Li(p,n) reaction. Finally, the spectroscopic capabilities and potential of C 7 LYC are discussed in the context of developing this emerging scintillator for targeted science applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the Neutron Data Standards

With the need for improving existing nuclear data evaluations, (e.g., ENDF/B-VIII.0 and JEFF-3.3 releases) the first step was to evaluate the standards for use in such a library. This new standards evaluation made use of improved experimental data and some developments in the methodology of analysis and evaluation. In addition to the work on the traditional standards, this work produced the extension of some energy ranges and includes new reactions that are called reference cross sections. Since the effort extends beyond the traditional standards, it is called the neutron data standards evaluation. This international effort has produced new evaluations of the following cross section standards: the H(n,n), 6 Li(n,t), 10 B(n,α), 10 B(n,α 1 γ), nat C(n,n), Au(n,γ), 235 U(n,f) and 238 U(n,f). Also in the evaluation process the 238 U(n,γ) and 239 Pu(n,f) cross sections that are not standards were evaluated. Evaluations were also obtained for data that are not traditional standards: the Maxwellian spectrum averaged cross section for the Au(n,γ) cross section at 30 keV; reference cross sections for prompt γ-ray production in fast neutron-induced reactions; reference cross sections for very high energy fission cross sections; the 252 Cf spontaneous fission neutron spectrum and the 235 U prompt fission neutron spectrum induced by thermal incident neutrons; and the thermal neutron constants. The data and covariance matrices of the uncertainties were obtained directly from the evaluation procedure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of polystyrene scintillator fiber array and monolithic polystyrene for neutron imaging and radiography

The neutron imaging diagnostic at the National Ignition Facility has been operating since 2011 generating neutron images of deuterium-tritium (DT) implosions at peak compression. The current design features a scintillating fiber array, which allows for high imaging resolution to discern small-scale structure within the implosion. In recent years, it has become clear that additional neutron imaging systems need to be constructed in order to provide 3D reconstructions of the DT source and these additional views need to be on a shorter line of sight. As a result, there has been increased effort to identify new image collection techniques that improve upon imaging resolution for these next generation neutron imaging systems, such as monolithic deuterated scintillators. This work details measurements performed at the Weapons Neutron Research Facility at Los Alamos National Laboratory that compares the radiographic abilities of the fiber scintillator with a monolithic scintillator, which may be featured in a future short line of sight neutron imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

α and 2 p 2 n emission in fast neutron-induced reactions on Ni 60

The cross sections for populating the residual nucleus in the reaction A Z X(n,x) A-4 Z-2 Y exhibit peaks as a function of incident neutron energy corresponding to the (n,n'α) reaction and, at higher energy, to the (n,2p3n) reaction. In addition, the relative magnitudes of these peaks vary with the Z of the target nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent Work Leading Towards a New Evaluation of the Neutron Standards

A new version of the ENDF/B library has been planned. The first step in producing this new library is evaluating the neutron standards. An evaluation is now underway with support from a Data Development Project of the IAEA. In addition to the neutron cross section standards, new evaluations are being done for prompt fission neutron spectra and a number of reference data. Efforts have been made to handle uncertainties in a proper way in these evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The LANL/LLNL Prompt Fission Neutron Spectrum Program at LANSCE and Approach to Uncertainties

New data on the prompt fission neutron spectra (PFNS) from neutron-induced fission with higher accuracies are needed to resolve discrepancies in the literature and to address gaps in the experimental data. The Chi-Nu project, conducted jointly by LANL and LLNL, aims to measure the shape of the PFNS for fission of {sup 239}Pu induced by neutrons from 0.5 to 20 MeV with accuracies of 3–5% in the outgoing energy from 0.1 to 9 MeV and 15% from 9 to 12 MeV and to provide detailed experimental uncertainties. Neutrons from the WNR/LANSCE neutron source are being used to induce fission in a Parallel-Plate Avalanche Counter (PPAC). Two arrays of neutron detectors are used to cover the energy range of neutrons emitted promptly in the fission process. Challenges for the present experiment include background reduction, use of {sup 239}Pu in a PPAC, and understanding neutron detector response. Achieving the target accuracies requires the understanding of many systematic uncertainties. The status and plans for the future will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiple-scattering Corrections to Measurements of the Prompt Fission Neutron Spectrum

The Chi-Nu project, conducted jointly by LANL and LLNL, aims to measure the shape of the prompt fission neutron spectrum (PFNS) for fission of {sup 239}Pu induced by neutrons from 50 keV to 15 MeV with accuracies of 3–5% in the outgoing energy from 50 keV to 9 MeV and 15% from 9 to 15 MeV. In order to meet this goal, detailed Monte Carlo simulations are being used to assess the importance and effect of every component in the experimental configuration. As part of this effort, we have also simulated some past PFNS measurements to identify possible sources of systematic error. We find that multiple scattering plays an important role in the target geometry, collimators, and detector response and that past experiments probably underestimated the extent of this effect.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Millisecond Isomer Lifetime Measurements at LANSCE

New half-life measurements have been made of the millisecond isomers {sup 71m}Ge, {sup 114m2}I, {sup 208m}Bi, {sup 88m1}Y, {sup 88m2}Y, and {sup 75m}As populated in neutron-induced reactions. These measurements were made using the unique time structure of the LANSCE/WNR neutron source, by observing the γ-ray decays of the isomers during the time between the LANSCE proton macropulses. Two different LANSCE proton beam time structures were used. The GEANIE array of HPGe detectors was used to detect the γ-ray decays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗