Engineering Papers⌕ Search

Engineering topics

Nelson, Carl

Publications and source records attributed to Nelson, Carl.

Multi-Institutional Experience of Ductal Carcinoma In Situ in Black vs White Patients Treated With Breast-Conserving Surgery and Whole Breast Radiation Therapy

Purpose: Given the paucity of data on racial disparities in ductal carcinoma in situ (DCIS), the data from a multi-institutional cohort of DCIS patients treated with breast-conserving surgery and whole breast radiation therapy (RT) were analyzed to determine whether racial disparities or differences exist. Methods and Materials: A total of 533 white and 76 black DCIS patients from 3 university-based cancer centers were uniformly treated with breast-conserving surgery and RT. All patient data were collected and analyzed as a function of race. Results: The median follow-up was 5.2 years. No significant racial differences were seen in tumor size, age at diagnosis, estrogen receptor status, necrosis, or grade (all P>.05). Of the treatment parameters, the RT dose delivered, boost, positive margin rates, frequency of hormone receptor status assessment, and receipt of hormonal therapy for the 2 cohorts did not significantly differ (all P>.05). The local relapse-free survival was similar at 5 years (96.1% and 98.1%, P=.399) and 10 years (92.8% vs 95.8%, P=.360), with no significant overall survival difference at 10 years (94.0% vs 88.9%, P=.290) between the white and black patients, respectively. On multivariate analysis, race was not an independent predictor of local relapse-free survival or overall survival when accounting for age, grade, and margin status. Conclusion: In our large cohort of DCIS patients uniformly treated at 3 institutions with breast conservation without any apparent differences in treatment delivery parameters, we demonstrated that the clinical and pathologic features and local survival outcomes did not differ as a function of race. Our results suggest that when black patients with DCIS are appropriately selected for breast conservation and receive adjuvant RT without racial disparities in the treatment parameters, differences in the outcomes as a function of race do not exist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Helical Intensity-Modulated Radiotherapy, Intensity-Modulated Radiotherapy, and 3D-Conformal Radiation Therapy for Pancreatic Cancer

We assessed dosimetric differences in pancreatic cancer radiotherapy via helical intensity-modulated radiotherapy (HIMRT), linac-based IMRT, and 3D-conformal radiation therapy (3D-CRT) with regard to successful plan acceptance and dose to critical organs. Dosimetric analysis was performed in 16 pancreatic cases that were planned to 54 Gy; both post-pancreaticoduodenectomy (n = 8) and unresected (n = 8) cases were compared. Without volume modification, plans met constraints 75% of the time with HIMRT and IMRT and 13% with 3D-CRT. There was no statistically significantly improvement with HIMRT over conventional IMRT in reducing liver V35, stomach V45, or bowel V45. HIMRT offers improved planning target volume (PTV) dose homogeneity compared with IMRT, averaging a lower maximum dose and higher volume receiving the prescription dose (D100). HIMRT showed an increased mean dose over IMRT to bowel and liver. Both HIMRT and IMRT offer a statistically significant improvement over 3D-CRT in lowering dose to liver, stomach, and bowel. The results were similar for both unresected and resected patients. In pancreatic cancer, HIMRT offers improved dose homogeneity over conventional IMRT and several significant benefits to 3D-CRT. Factors to consider before incorporating IMRT into pancreatic cancer therapy are respiratory motion, dose inhomogeneity, and mean dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Less-Toxic Coatings for Inhibiting Corrosion of Aluminum

Two recently invented families of conversion- coating processes have been found to be effective in reducing or preventing corrosion of aluminum alloys. These processes offer less-toxic alternatives to prior conversion-coating processes that are highly effective but have fallen out of favor because they generate chromate wastes, which are toxic and carcinogenic. Specimens subjected to these processes were found to perform well in standard salt-fog corrosion tests.

Minevski, Zoran↗

Isomolybdate conversion coatings

A conversion coating solution and process forms a stable and corrosion-resistant layer on metal substrates or layers or, more preferably, on a boehmite layer or other base conversion coating. The conversion coating process involves contacting the substrate, layer or coating with an aqueous alkali metal isomolybdate solution in order to convert the surface of the substrate, layer or coating to a stable conversion coating. The aqueous alkali metal molybdates are selected from sodium molybdate (Na.sub.2 MoO.sub.4), lithium molybdate (Li.sub.2 MoO.sub.4), potassium molybdate (K.sub.2 MoO.sub.4), or combinations thereof, with the most preferred alkali metal molybdate being sodium molybdate. The concentration of alkali metal molybdates in the solution is preferably less than 5% by weight. In addition to the alkali metal molybdates, the conversion coating solution may include alkaline metal passivators selected from lithium nitrate (LiNO.sub.3), sodium nitrate (NaNO.sub.3), ammonia nitrate (NH.sub.4 NO.sub.3), and combinations thereof; lithium chloride, potassium hexafluorozirconate (K.sub.2 ZrF.sub.6) or potassium hexafluorotitanate (K.sub.2 TiF.sub.6).

Minevski, Zoran↗

Conversion coatings prepared or treated with calcium hydroxide solutions

A conversion coating process that forms a stable and corrosion-resistant oxide layer on metal or metal oxide substrates or layers. Particularly, the conversion coating process involves contacting the metal or metal oxide substrate or layer with the aqueous calcium hydroxide solutions in order to convert the surface of the substrate to a stable metal oxide layer or coating. According to the present invention, the calcium hydroxide solution is prepared by removing carbon dioxide from water or an aqueous solution before introducing the calcium hydroxide. In this manner, formation of calcium carbonate particles is avoided and the porosity of the conversion coating produced by the calcium hydroxide solution is reduced to below about 1%.

Minevski, Zoran↗