Comparison of Heat Flux Gages for High Enthalpy Flows - NASA Ames and IRS

This article is a companion to a paper on heat flux measurements as initiated under a Space Act Agreement in 2011. The current focus of this collaboration between the Institute of Space Systems (IRS) of the University of Stuttgart and NASA Ames Research Center is the comparison and refinement of diagnostic measurements. A first experimental campaign to test different heat flux gages in the NASA Interaction Heating Facility (IHF) and the Plasmawindkanaele (PWK) at IRS was established. This paper focuses on the results of the measurements conducted at IRS. The tested gages included a at face and hemispherical probe head, a 4" hemispherical slug calorimeter, a null-point calorimeter from Ames and a null-point calorimeter developed for this purpose at IRS. The Ames null-point calorimeter was unfortunately defective upon arrival. The measured heat fluxes agree fairly well with each other. The reason for discrepancies can be attributed to signal-to-noise levels and the probe geometry.

spacecraft reentry↗

Remote Recession Sensing of Ablative Heat Shield Materials

Tests were performed to demonstrate the feasibility of a new method of measuring surface recession of a material sample during arc-jet testing in the NASA Ames mARC subscale developmental facility. The measurement principle was inspired through tracer elements such as Ca and Na which were seen in the spectra taken during the airborne observation campaign of the Stardust re-entry and which could be clearly observed standing out against the emission spectra emitted by postshock layer and glowing surface of the re-entry capsule. The measurement principle involves seeding of the heat shield materials at a defined depth with tracer elements which show strong and characteristic emission lines in the post shock plasma. Once the material recession reaches the seeding depth, these elements get into the hot plasma and show up in the emission spectra. The methodology was successfully demonstrated during arc-jet testing of phenolic impregnated carbonablator (PICA) material which was seeded in depth with a mixture of NaCl and MgCl in powder form. In the emission spectroscopy data, the emission lines of Mg and Na showed up about 1.5 seconds after probe insertion into the arc-jet plasma and vanished after another 2.5 seconds when recessionhad consumed the seeding material. From these data, a recession rate of about 1 mm/s is estimated.The heat flux during the test was measured to be 2575 W/sq cm on a hemispherical heat flux probewhich corresponds to a heat flux of 1036 W/sq cm on the rectangular test articles. An estimate for a lower limit of the surface temperature of 2800K during the test was obtained by fitting Planck radiation to the continuum spectra emitted by the PICA sample. Typical recession rates of PICA during testing in the large arc-jet facilities at similar test conditions are reported to be on the order of 0.05 to 0.1 cm/s which agrees well with the recession rates of 0.05-0.06 cm/s estimated from the emission spectroscopy data. Further tests under better controlled conditions are suggested to quantify this measurement method. Through a different choice of seeding materials with lower melting point, an extension of the measurement principle to monitor char depth seems feasible but was not yet demonstrated. Possible applications besides ground testing are recession and possibly char depth measurements during real re-entry. Detection through emission spectroscopy could be accomplished through ground based or airborne observation as performed during the Stardust and Hayabusa re-entries, or through on-board spectrometers. A suitable mission would be the re-entryof the OSIRIS-REX mission planned for late 2023. The measured data are presented and interpreted, the results and details of future applications are discussed.

instrumentation↗

Remote Recession Sensing of Ablative Heat Shield Materials

Material recession and charring are two major processes determining the performance of ablative heat shield materials. Even in ground testing, the characterization of these two mechanisms relies on measurements of material thickness before and after testing, thus providing only information integrated over the test time. For recession measurements, optical methods such as imaging the sample surface during testing are under investigation but require high alignment and instrument effort, therefore being not established as a standard measurement method. For char depth measurements, the most common method so far consists in investigation of sectioned samples after testing or in the case of Stardust where core extractions were performed to determine char information. In flight, no reliable recession measurements are available, except total recession after recovering the heat shield on ground. Developments of mechanical recession sensors have been started but require substantial on board instrumentation adding mass and complexity. In this work, preliminary experiments to evaluate the feasibility of remote sensing of material recession and possibly char depth through optically observing the emission signatures of seeding materials in the post shock plasma is investigated. It is shown that this method can provide time resolved recession measurements without the necessity of accurate alignment procedures of the optical set-up and without any instrumentation on board of a spacecraft. Furthermore, recession data can be obtained without recovering flight hardware which would be a huge benefit for inexpensive heat shield material testing on board of small re-entry probes, e.g. on new micro-satellite re-entry probes as a possible future application of Cubesats or RBR

instrumentation↗

Monitoring Temperature in High Enthalpy Arc-heated Plasma Flows using Tunable Diode Laser Absorption Spectroscopy

A tunable diode laser sensor was designed for in situ monitoring of temperature in the arc heater of the NASA Ames IHF arcjet facility (60 MW). An external cavity diode laser was used to generate light at 777.2 nm and laser absorption used to monitor the population of electronically excited oxygen atoms in an air plasma flow. Under the assumption of thermochemical equilibrium, time-resolved temperature measurements were obtained on four lines-of-sight, which enabled evaluation of the temperature uniformity in the plasma column for different arcjet operating conditions.

Martin, Marcel Nations↗

Radial Profiles of the Plasma Electron Characteristics in a 30 kW Arc Jet

The present effort aims to strengthen modeling work conducted at the NASA Ames Research Center by measuring the critical plasma electron characteristics within and slightly outside of an arc jet plasma column. These characteristics are intended to give physical insights while assisting in the formulation of boundary conditions to validate full scale simulations. Single and triple Langmuir probes have been used to achieve estimates of the electron temperature (T(sub e)), electron number density (n(sub e)) and plasma potential (outside of the plasma column) as probing location is varied radially from the flow centerline. Both the electron temperature and electron number density measurements show a large dependence on radial distance from the plasma column centerline with T(sub e) approx. = (3 - 12 eV and n(sub e) approx. = 10(exp 12) - 10(exp 14)/cu cm.

Codron, Douglas A.↗

Radial Profiles of Plasma Electron Characteristics in a Low-Power Arcjet

Since 1960, the Arc Jet Complex at NASA Ames Research Center has been a source of long-duration, high-enthalpy flow for materials testing with application to the thermal protection of aerospace vehicle components. From their inception the facilities have played an integral role supporting many of NASA's space flight programs and numerous DoD projects. In recent years advancements in computational fluid dynamics (CFO) have made the resultant models a valuable tool for assessing and predicting performance, however, the inherent limitation of models to compensate for a dissociated, transitionally high temperature nonequilibrated flowfield have made further measurements necessary. The use of electrostatic probe diagnostics within similarly harsh plasma environments in previous studies have been met with much success. In this study, the use of a single Langmuir probe was implemented to characterize the plasma parameters of interest as they vary radially within a large volume of the plume. Classical Langmuir probe theory was applied to achieve first order estimates of the heavy particle temperature, the ratio T(sub i)/T(sub e), and the ionization fraction. As expected, both the electron temperature and electron density measurements show a dependence on radial distance from the plume centerline, with electron density profiles showing the largest dependence. This paper aims to validate and strengthen modeling work conducted at the NASA Ames Research Center by measuring the critical plasma parameters (electron temperature, electron density, and plasma potential) within the arc plume of a subscale arc jet. These parameters are intended to give physical insight into the flow characteristics while providing the necessary boundary conditions to validate full scale simulations.

Codron, Douglas↗

Surface Catalysis and Oxidation on Stagnation Point Heat Flux Measurements in High Enthalpy Arc Jets

Heat flux sensors are routinely used in arc jet facilities to determine heat transfer rates from plasma plume. The goal of this study is to assess the impact of surface composition changes on these heat flux sensors. Surface compositions can change due to oxidation and material deposition from the arc jet. Systematic surface analyses of the sensors were conducted before and after exposure to plasma. Currently copper is commonly used as surface material. Other surface materials were studied including nickel, constantan gold, platinum and silicon dioxide. The surfaces were exposed to plasma between 0.3 seconds and 3 seconds. Surface changes due to oxidation as well as copper deposition from the arc jets were observed. Results from changes in measured heat flux as a function of surface catalycity is given, along with a first assessment of enthalpy for these measurements. The use of cupric oxide is recommended for future heat flux measurements, due to its consistent surface composition arc jets.

Nawaz, Anuscheh↗

Influence of Catalysis and Oxidation on Slug Calorimeter Measurements in Arc Jets

Arc jet tests play a critical role in the characterization and certification of thermal protection materials and systems (TPS). The results from these arc jet tests feed directly into computational models of material response and aerothermodynamics to predict the performance of the TPS in flight. Thus the precise knowledge of the plasma environment to which the test material is subjected, is invaluable. As one of the environmental parameters, the heat flux is commonly measured. The measured heat flux is used to determine the plasma enthalpy through analytical or computational models. At NASA Ames Research Center (ARC), slug calorimeters of a geometrically similar body to the test article are routinely used to determine the heat flux. A slug calorimeter is a thermal capacitance-type calorimeter that uses the temperature rise in a thermally insulated slug to determine the heat transfer rate, see Figure 1(left). Current best practices for measuring the heat flux with a slug calorimeter are described in ASTM E457 - 96. Both the calorimeter body and slug are made of Oxygen Free High Conductivity Copper, and are cleaned before each run.

Nawaz, Anuscheh↗

Closed Gap Slug Calorimeter for Plasma Stream Characterization

Slug calorimeters are used in sheer and stagnation mode to characterize heat flux levels for high enthalpy streams. The traditional design features a gap between slug and holder, which can be of concern in these convective heat flux environments. The challenge is to develop a calorimeter that closes the gap to gas flow, but largely maintains thermal insulation of the slug. The work presented herein introduces two new slug calorimeter designs featuring a closed gap. This is done using either aerogel as a filler or press fitting the slug with a disk. The designs were verified and compared to the baseline calorimeter design under radiative heat flux. Building on this, the calorimeters were exposed to convective heat flux in the arc-jet facilities. Results from the new designs and conclusions on the impact of the gap in convective heat flux will be shown.

Nawaz, Anuscheh↗

Plasma Sheet Velocity Measurement Techniques for the Pulsed Plasma Thruster SIMP-LEX

The velocity of the first plasma sheet was determined between the electrodes of a pulsed plasma thruster using three measurement techniques: time of flight probe, high speed camera and magnetic field probe. Further, for time of flight probe and magnetic field probe, it was possible to determine the velocity distribution along the electrodes, as the plasma sheet is accelerated. The results from all three techniques are shown, and are compared for one thruster geometry.

Nawaz, Anuscheh↗