Engineering PapersSearch

Engineering topics

Nath, S.

Publications and source records attributed to Nath, S..

Characteristics of Electromagnetic Pulse Propagation in Metal

It is well known that the solution of the diffusion equation for an electromagnetic field with a time harmonic term, e(sup iwt), is in the form of a traveling wave whose amplitude attenuates over distance into a conducting medium. As the attenuation is an increasing function of frequency, the high frequency components attenuate more rapidly than those of low ones upon entering a well conducting object. At the same time, the phase velocity of an individual component is also an increasing function of frequency causing a broadening of the pulse traveling inside a conductor. In the results of our previous study of numerical simulations, the problem of using a gaussian input pulse was immediately clear. First, having the dominant frequency components distributed around zero, the movement of the peak was not well defined. Second, with the amplitude of fourier components varying slowly over a wide range, the dispersion-induced blurring of the peak position was seen to be severe. For the present study, we have used a gaussian modulated single frequency sinusoidal wave, i. e., the carrier, as an input pulse in an effort to improve the issues related to the unclear movement of peak and dispersion as described above. This was based on the following two anticipated advantages: First, the packet moves in a conductor at the group velocity calculated at the carrier frequency, which means it is well controllable. Second, the amplitude of frequency components other than that of the carrier can be almost negligible, such that the effect of dispersion can be significantly reduced. A series of experiments of transmitting electromagnetic pulses through aluminum plates of various thickness was performed to test the validity of the above points. The results of numerical simulation based on wave propagation are discussed with respect to the experimental results. Finally, a simple simulation was performed based on diffusion of a continuous sine wave input and the results are compared with those of a single frequency sinusoidal wave observed over time at difference locations inside a conductor.

Namkung, M.

Self-Nulling Eddy Current Probe for Surface and Subsurface Flaw Detection

An eddy current probe which provides a null-signal in the presence of unflawed material without the need for any balancing circuitry has been developed at NASA Langley Research Center. Such a unique capability of the probe reduces set-up time, eliminates tester configuration errors, and decreases instrumentation requirements. The probe is highly sensitive to surface breaking fatigue cracks, and shows excellent resolution for the measurement of material thickness, including material loss due to corrosion damage. The presence of flaws in the material under test causes an increase in the extremely stable and reproducible output voltage of the probe. The design of the probe and some examples illustrating its flaw detection capabilities are presented.

Wincheski, B.

Application of Self Nulling Eddy Current Probe Technique to the Detection of Fatigue Crack Initiation and Control of Test Procedures

A major part of fracture mechanics is concerned with studying the initiation and propagation of fatigue cracks. This typically requires constant monitoring of crack growth during fatigue cycles and the knowledge of the precise location of the crack tip at any given time. One technique currently available for measuring fatigue crack length is the Potential Drop method. The method, however, may be inaccurate if the direction of crack growth deviates considerably from what was assumed initially or the curvature of the crack becomes significant. Another popular approach is to optically view the crack using a high magnification microscope, but this entails a person constantly monitoring it. The present proposed technique uses an automated scheme, in order to eliminate the need for a person to constantly monitor the experiment. Another technique under development elsewhere is to digitize an optical image of the test specimen surface and then apply a pattern recognition algorithm to locate the crack tip. A previous publication showed that the self nulling eddy current probe successfully tracked a simulated crack in an aluminum sample. This was the impetus to develop an online real time crack monitoring system. An automated system has been developed which includes a two axis scanner mounted on the tensile testing machine, the probe and its instrumentation and a personal computer (PC) to communicate and control all the parameters. The system software controls the testing parameters as well as monitoring the fatigue crack as it propagates. This paper will discuss the experimental setup in detail and demonstrate its capabilities. A three dimensional finite element model is utilized to model the magnetic field distribution due to the probe and how the probe voltage changes as it scans the crack. Experimental data of the probe for different samples under zero load, static load and high cycle fatigue load will be discussed. The final section summarizes the major accomplishments of the present work, the elements of the future R&D needs and the advantages and disadvantages of using this system in the laboratory and field.

Namkung, M.

A New Electromagnetic Instrument for Thickness Gauging of Conductive Materials

Eddy current techniques are widely used to measure the thickness of electrically conducting materials. The approach, however, requires an extensive set of calibration standards and can be quite time consuming to set up and perform. Recently, an electromagnetic sensor was developed which eliminates the need for impedance measurements. The ability to monitor the magnitude of a voltage output independent of the phase enables the use of extremely simple instrumentation. Using this new sensor a portable hand-held instrument was developed. The device makes single point measurements of the thickness of nonferromagnetic conductive materials. The technique utilized by this instrument requires calibration with two samples of known thicknesses that are representative of the upper and lower thickness values to be measured. The accuracy of the instrument depends upon the calibration range, with a larger range giving a larger error. The measured thicknesses are typically within 2-3% of the calibration range (the difference between the thin and thick sample) of their actual values. In this paper the design, operational and performance characteristics of the instrument along with a detailed description of the thickness gauging algorithm used in the device are presented.

Fulton, J. P.

Issues on Reproducibility/Reliability of Magnetic NDE Methods

One of the critical elements related to the practicality of any NDE technique is its reproducibility under nominally the same inspection conditions. The results of certain test methodologies, however, are not always repeatable and understanding the origin of the irreproducibility is often as critical as obtaining reproducible results. One example is the characterization of residual stress in structural ferromagnets using the magnetoacoustic (MAC) method. Although it has not been widely publicized, the test results of this method are known to be time-dependent. Two distinct types of time dependencies have been observed during testing. The first type has a clearly definable relaxation time, while no such trend has been observed for the second. The purpose of the present study is to systematically investigate the time dependence of the second type, to find out the range and, if possible, the origin of the variation in the test results. For this, MAC curves were obtained under various stress levels and the tests were repeated over time. Particular attention was given to whether noise in the measuring device or a change in the laboratory environment could have been a contributing factor. The steel samples used for the study were cut from C- and U-class railroad wheels. The MAC behavior of these samples was reported previously. Each steel sample was first machined to be a cylindrical rod of 3.175 cm (1.25 in) in diameter and 26.67 cm (10.5 in) in length. The center portion of the samples were further machined to form a pair of flat and parallel surfaces for the launch and reflection of the ultrasonic pulses. Data acquisition involved two major elements; magnetic and acoustic measurements. Throughout the experiment the net magnetic induction, B, was measured by integrating the induction pickup coil output using an integrating fluxmeter. The acoustic measurements employed the phase-locked technique which will be described in the following.

Namkung, M.

Combined investigation of Eddy current and ultrasonic techniques for composite materials NDE

Advanced composites are not without trade-offs. Their increased designability brings an increase in the complexity of their internal geometry and, as a result, an increase in the number of failure modes associated with a defect. When two or more isotropic materials are combined in a composite, the isotropic material failure modes may also combine. In a laminate, matrix delamination, cracking and crazing, and voids and porosity, will often combine with fiber breakage, shattering, waviness, and separation to bring about ultimate structural failure. This combining of failure modes can result in defect boundaries of different sizes, corresponding to the failure of each structural component. This paper discusses a dual-technology NDE (Non Destructive Evaluation) (eddy current (EC) and ultrasonics (UT)) study of graphite/epoxy (gr/ep) laminate samples. Eddy current and ultrasonic raster (Cscan) imaging were used together to characterize the effects of mechanical impact damage, high temperature thermal damage and various types of inserts in gr/ep laminate samples of various stacking sequences.

Davis, C. W.

Mutual Inductance Problem for a System Consisting of a Current Sheet and a Thin Metal Plate

Rapid inspection of aircraft structures for flaws is of vital importance to the commercial and defense aircraft industry. In particular, inspecting thin aluminum structures for flaws is the focus of a large scale R&D effort in the nondestructive evaluation (NDE) community. Traditional eddy current methods used today are effective, but require long inspection times. New electromagnetic techniques which monitor the normal component of the magnetic field above a sample due to a sheet of current as the excitation, seem to be promising. This paper is an attempt to understand and analyze the magnetic field distribution due to a current sheet above an aluminum test sample. A simple theoretical model, coupled with a two dimensional finite element model (FEM) and experimental data will be presented in the next few sections. A current sheet above a conducting sample generates eddy currents in the material, while a sensor above the current sheet or in between the two plates monitors the normal component of the magnetic field. A rivet or a surface flaw near a rivet in an aircraft aluminum skin will disturb the magnetic field, which is imaged by the sensor. Initial results showed a strong dependence of the flaw induced normal magnetic field strength on the thickness and conductivity of the current-sheet that could not be accounted for by skin depth attenuation alone. It was believed that the eddy current imaging method explained the dependence of the thickness and conductivity of the flaw induced normal magnetic field. Further investigation, suggested the complexity associated with the mutual inductance of the system needed to be studied. The next section gives an analytical model to better understand the phenomenon.

Fulton, J. P.

An Ultrasonic Study on Anelasticity in Metals

A new ultrasonic approach for monitoring the anelastic behavior of metals and alloys was presented. The approach poses some problems related to separating the temperature dependence of the anelastic phenomena from the natural wave velocity s susceptibility to temperature changes. However, these effects can be distinguished and separated without much difficulty. Due to its high sensitivity to microstructural changes, the new technique will be quite valuable when used in conjunction with strain gauges for studying anelastic behavior. The two techniques should complement each other quite well. In the future, tests using both the P2L2 and strain gauges to more thoroughly monitor the samples will be conducted. Further work will be done to fully characterize the temperature sensitivity of the velocity and provide a more solid foundation for separating its effects.

Namkug, M.