Engineering Papers⌕ Search

Engineering topics

Nandanoori, Sai Pushpak

Publications and source records attributed to Nandanoori, Sai Pushpak.

Self-Aware Local Autonomous and Semi-Cooperative Control for Cross-Layered Resilience (SLAC3R)

The objective of this work is to develop and demonstrate novel, adaptive, lightweight algorithms that enable the decision-making agents in a large cyber-physical network to act both autonomously and in collaborative harmony to enforce assured resilience across spatiotemporal layers, even under unforeseen adversarial scenarios (e.g., high- impact-low-probability events). Towards this end, the proposed solution will serve as minimally invasive add-on layers that bridge the existing (faster, reactive) local myopic controls and (slower, predictive) centralized optimization. Importantly, the proposed algorithms will enable the multi-agent network to autonomously and collaboratively enforce resilient operation under no or limited communication environment typical of severe cyber- physical adversarial events. The expected outcome of this effort is a suite of prototype, open-source, software algorithms for safety-aware local autonomous and semi-cooperative control (SLAC3R), demonstrated on networked microgrids (via RD2C/Thrust-1 OPAL-RT testbed).

97 MATHEMATICS AND COMPUTING↗

Transient Stability Analysis of Direct Droop-Controlled Grid-Forming Inverter with Current Clipping as Current Limiting Control

This paper investigates the transient stability of the direct droop-controlled grid-forming (GFM) inverter which employs the current clipping-based approach for overcurrent limitation. An equivalent circuit model of the direct-droop GFM inverter with current clipping is developed for this purpose. It is shown that during overcurrent conditions, the GFM inverter with current clipping acts as a voltage source with a virtual resistance behind the inverter filters. To compute the parameters of this virtual resistance an analytical expression is given in the paper. Then utilizing the developed circuit, a criteria to exit current limiting during post-fault conditions is given. The developed analytical approaches are then validated through electromagnetic transient (EMT) simulation results in PSCAD software and finally concluding remarks are drawn.

Mohiuddin, Sheik Mohammad↗

Guest Editorial: Special section on Resilient Control of Cyber-Physical Power and Energy Systems

Our power and energy systems are becoming more and more integrated and interconnected. The increasing integration of edge devices and dependence on cyber infrastructure provides both the potential for benefits and risks. The integration enables more dynamic and flexible control paradigms while at the same time increasing the cyberattack surface and uncertainty of behavior. Control methodology in this new world must be designed for resilience and must have the ability to withstand, react, and respond to both physical faults and cyber-induced threats. Finally, understanding system resilience under adverse conditions requires studying control performance and how cyber infrastructure can integrate with and support the overall resilience of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Losing Control of Your Linear Network? Try Resilience Theory

Resilience of cyber-physical networks to unexpected failures is a critical need widely recognized across domains. For instance, power grids, telecommunication networks, transportation infrastructures, and water treatment systems have all been subject to disruptive malfunctions and catastrophic cyberattacks. Following such adverse events, we investigate scenarios where a node of a linear network suffers a loss of control authority over some of its actuators. These actuators are not following the controller's commands and are instead producing undesirable outputs. The repercussions of such a loss of control can propagate and destabilize the whole network despite the malfunction occurring at a single node. To assess system vulnerability, we establish resilience conditions for networks with a subsystem enduring a loss of control authority over some of its actuators. Furthermore, we quantify the destabilizing impact on the overall network when such a malfunction perturbs a nonresilient subsystem. We illustrate our resilience conditions on two academic examples, on an islanded microgrid and on the linearized IEEE 39-bus system.

97 MATHEMATICS AND COMPUTING↗

Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation

Here, this letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct (d)-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗

A Data-driven approach to Determining the Fidelity in the Hardware-in-the-loop Systems using Subspace Identification Method

One of the major questions in any Hardware-in-the-loop (HiL) simulation is to understand the fidelity of the HiL simulation itself which is most often indicated qualitatively as either high or low instead of quantifying it. Being cognizant of the level of fidelity forms the crux to assess the validity and credibility of the HiL simulation. In this work, we address this issue by developing a systematic, data-driven approach to assess the fidelity of any HiL simulation, and more specifically, the fidelity of the interface between the simulator and hardware in an HiL simulation. Applying a subspace identification method, a linear system representing the interface is obtained from the time-series data captured between the hardware and simulator in the HiL simulation. Finally, the fidelity is defined based on this linear system properties. The proposed data-driven fidelity quantification framework is illustrated on the IEEE 123 node feeder system running on HYPERSIM and interacting with virtual protection relays.

97 MATHEMATICS AND COMPUTING↗

Operator-theoretic Resilience Calculations (ORC)

This project developed operational metrics to characterize the resilience of a dynamic network in real-time from time-series data by proposing: a) Resilience ratio b) Recovery energy. Resilience analysis considers the controllability and observability and provides a real-time under- standing on resilience without creating/simulating them. The report focuses on the application of resilience metrics on the HYPERSIM data and insights obtained.

97 MATHEMATICS AND COMPUTING↗