Engineering Papers⌕ Search

Engineering topics

Nakano, T.

Publications and source records attributed to Nakano, T..

At least 37 records · Page 2

A New Method of Absorption-Phase Nanotomography for 3D Observation of Mineral-Organic-Water Textiles and its Application to Pristine Carbonaceous Chondrites

Pristine carbonaceous chondrites contain fine-grained matrix, which is composed largely of amorphous silicates, sub-micron silicate and sulfide crystals, and organic materials. They are regarded as primitive dust in the early Solar System that have suffered minimal alteration in their parent bodies. The matrix generally has different lithologies; some of them are unaltered but some are more or less aqueously altered. Their textures have been examined in 2D usually by FE-SEM/EDS, TEM/EDS, nano-SIMS and micro-XRD. Observation of their complex fine textures, such as spatial relation between different lithologies in 3D, is important for understanding aggregation and alteration processes. Synchrotron radiation (SR)-based X-ray tomography reveals 3D structures nondestructively with high spatial resolution of approximately greater than 100 nm. We have developed a new technique using absorption contrasts called "dual-energy tomography" (DET) to obtain 3D distribution of minerals at SPring-8, SR facility in Japan, and applied successfully to Itokawa particles. Phase and absorption contrast images can be simultaneously obtained in 3D by using "scanning-imaging x-ray microscopy" (SIXM) at SPring-8, which can discriminate between void, water and organic materials. We applied this technique combined with FIB micro-sampling to carbonaceous chondrites to search for primitive liquid water. In this study, we combined the DET and SIXM to obtain three dimensional submicron-scale association between minerals, organic materials and water and applied this to pristine carbonaceous chondrites.

Tsuchiyama, A.↗

Primitive Liquid Water of the Solar System in an Aqueous Altered Carbonaceous Chondrite

Non-destructive 3D observations of the aqueous altered CM chondrite Sutter's Mill using scanning imaging x-ray microscopy (SIXM) showed that some of calcite and enstatite grains contain two-phase inclusion, which is most probably composed of liquid water and bubbles. This water should be primitive water responsible for aqueous alteration in an asteroid in the early solar system.

Tsuchiyama, A.↗

Search for heavy neutrinos in K + → μ + ν H decays

Here, evidence of a heavy neutrino, ν H , in the K + →μ + ν H decays was sought using the E949 experimental data with an exposure of 1.70 × 10 12 stopped kaons. With the major background from the radiative K + →μ + ν μ γ decay understood and suppressed, upper limits (90% C.L.) on the neutrino mixing matrix element between the muon and heavy neutrinos, |U μH | 2 , were set at the level of 10 –7 to 10 –9 for the heavy neutrino mass region 175 to 300 MeV/c 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Fluid Inclusions in a Carbonaceous Chondrite Using a New X-Ray Micro-Tomography Technique Combined with FIB Sampling

Early solar system aqueous fluids are preserved in some H chondrites as aqueous fluid inclusions in halite (e.g., [1]). Although potential fluid inclusions are also expected in carbonaceous chondrites [2], they have not been surely confirmed. In order to search for these fluid inclusions, we have developped a new X-ray micro-tomography technique combined with FIB sampling and applied this techniqu to a carbanaceous chondrite. Experimental: A polished thin section of Sutter's Mill meteorite (CM) was observed with an optical microscope and FE-SEM (JEOL 7001F) for chosing mineral grains of carbonates (mainly calcite) and sulfides (FeS and ZnS) 20-50 microns in typical size, which may have aqueous fluid inclusions. Then, a "house" similar to a cube with a roof (20-30 microns in size) is sampled from the mineral grain by using FIB (FEI Quanta 200 3DS). Then, the house was atached to a thin W-needle by FIB and imaged by a SR-based imaging microtomography system with a Fresnel zone plate at beamline BL47XU, SPring-8, Japan. One sample was imaged at two X-ray energies, 7 and 8 keV, to identify mineral phases (dual-enegy microtomography: [3]). The size of voxel (pixel in 3D) was 50-80 nm, which gave the effective spatial resolution of approx. 200 nm. A terrestrial quartz sample with an aqueous fluid inclusion with a bubble was also examined as a test sample by the same method. Results and discussion: A fluid inclusion of 5-8 microns in quartz was clearly identified in a CT image. A bubble of approx. 4 microns was also identified as refraction contrast although the X-ray absorption difference between fluid and bubble is small. Volumes of the fluid and bubble were obtained from the 3D CT images. Fourteen grains of calcite, two grains of iron sulfide and one grain of (Zn,Fe)S were examined. Ten calcite, one iron sulfide and one (Zn,Fe)S grains have inclusions >1 micron in size (the maximum: approx. 5 microns). The shapes are spherical or irregular. Tiny inclusions (<1 micron) are also present in all the grains examined. These results show that mineral grains have more inclusions than expected from 2D observations. The X-ray absorption of the inclusions shows that they are not solid inclusions. No bubbles were observed inside, indicating that we cannot determine whether they are really aqueous fluids or merely voids. One calcite grain has an inclusion approx. 2 microns in size, which seems to have a bubble and a tiny solid daughter crystal inside (three-phase inclusion). As we know the exact 3D position of the inclusion, we will anlyze the inclusion by SIMS after freezing the sample as has been done for a halite sample [3]. The present technique is useful for finding small inclusions not only in carbonaceous chondrites but also for terrestrial materials.

Tsuchiyama, A.↗

Realizations of the ITS-90 below 24.5561 K at NMIJ/AIST

The International Temperature Scale of 1990 (ITS-90) down to its defined minimum temperature of 0.65 K has been realized at the National Metrology Institute of Japan (NMIJ), using a {sup 3}He vapor pressure thermometer (VPT) from 0.65 K to 3.2 K, a {sup 4}He VPT from 2.2 K to 4.2 K, an interpolating constant-volume gas thermometer (ICVGT) from 3 K to 24.5561 K and standard platinum resistance thermometers (SPRTs) above 13.8803 K. The scales realized by these different thermometers in the overlapped temperature ranges differ among each other. These differences, also known as the non-uniqueness of the ITS-90, are estimated and reported in this paper. The difference between the scales of the SPRTs and ICVGT has a maximum of about 0.6 mK at temperatures close to 15 K, though it is about half of the propagation of the calibration uncertainties of the SPRT at the fixed points. The difference between the vapor pressure scales of {sup 4}He and {sup 3}He shows temperature dependence, which is consistent with that reported previously and has a maximum of about 0.2 mK at temperatures close to 3.1 K. The differences between the ICVGT scales with different lowest calibration temperatures are also estimated. The difference between the ICVGT scales with or without corrections for the aerostatic pressure head, the dead-space volume effect and the thermomolecular pressure difference has a maximum of about 0.17 mK.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of the triple-point temperatures of {sup 20}Ne, {sup 22}Ne and normal Ne

At the National Metrology Institute of Japan (NMIJ), the triple points of {sup 20}Ne and {sup 22}Ne were realized using modular sealed cells, Ec3Ne20 and Ec8Ne22, made by the Istituto Nazionale di Ricerca Metrologica (INRiM) in Italy. The difference of the triple-point temperatures of {sup 20}Ne and {sup 22}Ne was estimated by using the sub-range of standard platinum resistance thermometers (SPRTs) calibrated by NMIJ on the International Temperature Scale of 1990 (ITS-90). The melting curves obtained with the Ec3Ne20 and Ec8Ne22 cells show narrow widths (0.1 mK) over a wide range of the inverse of the melted fraction (1/F) from 1/F=1 to 1/F=10. The liquidus point T{sub tp} estimated by the melting curves from F∼0.5 to F∼0.85 using the Ec8Ne22 is 0.146 29 (4) K higher than that using the Ec3Ne20 cell, which is in good agreement with that observed by INRiM using the same cells. After correction of the effect of impurities and other isotopes for Ec3Ne20 and Ec8Ne22 cells, the difference of T{sub tp} between pure {sup 20}Ne and pure {sup 22}Ne is estimated to be 0.146 61 (4) K, which is consistent with the recent results reported elsewhere. The sub-ranges of SPRTs computed by using the triple point of {sup 20}Ne or {sup 22}Ne realized by the Ec3Ne20 cell or the Ec8Ne22 cell in place of the triple point of Ne for the defining fixed point of the ITS-90 are in good agreement with those realized on the basis of the ITS-90 at NMIJ within 0.03 mK, which is much smaller than the non-uniqueness and the sub-range inconsistency of SPRTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dependence of the triple point temperature of neon on isotopic composition and its implications for the ITS-90

The paper summarizes the results of an International Project started in 2003 aimed at formulating a correction for the variability of isotopic composition found in 'natural' neon, and presently not taken into account by the ITS-90 definition, whose consequent ambiguity leads to a combined uncertainty u{sub c}= 160 μK, whereas u{sub c}= 30-50 μK for the rest of the budget. After a very short summary of the Project results (a detailed Final Report will be published later) recommendations for the correction function are presented, in agreement with both the experimental data and the theoretical calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of the K 0 L →π⁰π⁰νν¯decay

The rare decay K 0 L →π⁰π⁰νν̄ was studied with the E391a detector at the KEK 12-GeV proton synchrotron. Based on 9.4×10⁹ K 0 L decays, an upper limit of 8.1×10⁻⁷ was obtained for the branching fraction at 90% confidence level. We also set a limit on the K 0 L →π⁰π⁰X (X→invisible particles) process; the limit on the branching fraction varied from 7.0×10⁻⁷ to 4.0×10⁻⁵ for the mass of X ranging from 50 MeV/c² to 200 MeV/c².

Ogata, R.↗

Three Dimensional Structures of Particles Recovered from the Asteroid Itokawa by the Hayabusa Mission and a Role of X-Ray Microtomography in the Preliminary Examination

Particles of regolith on S-type Asteroid 25143 Itokawa were successfully recovered by the Hayabusa mission of JAXA (Japan Aerospace Exploration Agency). Near-infrared spectral study of Itokawa s surface indicates that these particles are materials similar to LL5 or LL6 chondrites. High-resolution images of Itokawa's surface suggest that they may be breccias and some impact products. At least more than 1500 particles were identified as Itokawa origin at curation facility of JAXA. Preliminary analysis with SEM/EDX at the curation facility shows that they are roughly similar to LL chondrites. Although most of them are less than 10 micron in size, some larger particles of about 100 micron or larger were also identified. A part of the sample (probably several tens particles) will be selected by Hayabusa sample curation team, and sequential examination will start from January 2011 by Hayabusa Asteroidal Sample Preliminary Examination Team (HASPET). In mainstream of the analytical flow, each particle will be examined by microtomography, XRD and XRF first as nondestructive analyses, and then the particle will be cut by an ultra-microtome and examined by TEM, SEM, EPMA, SIMS, PEEM/XANES, and TOF-SIMS sequentially. Three-dimensional structures of Itokawa particles will be obtained by microtomography sub-team of HASPET. The results together with XRD and XRF will be used for design of later destructive analyses, such as determination of cutting direction and depth, to obtain as much information as possible from small particles. Scientific results and a role of the microtomography in the preliminary examination will be presented.

Tsuchiyama, A.↗

Search for Organic Nanoglobules in Carbonaceous Chondrites Using Microtomography

Primitive solar materials have various organic matters. In recent years, novel organic materials called organic nanoglobules of a few hundred micrometers in typical size were discovered in carbonaceous chondrites, IDPs, and comet 81P/Wild 2. The organic globules are spherical shape and in many cases with hollow structures. Composition of the globules are mainly aromatic carbon. The isotopic anomalies of SD and 6N 15 observed in the globules indicate that they were formed from photochemical reaction to ice particles at very low temperature environment, such as molecular clouds or outer protosolar disk. Aqueous alteration of organic matters and the gamma-ray irradiation to PAH are also suggested as alternative possible formation processes. If the globules are made from organic ice particles, the hollow regions of the globules are suggested to be once filled with volatile H20-rich organic ices, while if they were formed by aqueous alteration, the hollow regions should be filled with a fluid which caused the aqueous alteration. However, fluids in the globules have not been detected so far in the previous studies. If fluids were originally preserved in the hollows, they might be lost during destructive processes of sample separation or preparation for TEM observation. X-ray computed tomography (CT) is a nondestructive method which can determine 3-D internal structures of objects. SR (synchrotron radiation)-based imaging microtomography can give submicron spatial resolution [8] and was applied to micro textures in extraterrestrial materials, such as cometary grains captured by the Stardust mission [9]. If organic globules are observed non-destructively in carbonaceous chondrites by tomography, we can check the presence of fluids in the hollows. If fluids are preserved, we may analyze chemical and isotopic compositions of the fluids. The purpose of this study is to observe organic nanoglobules using imaging tomography for future analysis.

Matsumoto, T.↗

Three-Dimensional Shapes and Impactor Size Estimation of Stardust Impact

Impact tracks formed by cometary dust capture in silica aerogel collectors in the Stardust mission [1] have a variety of shapes, showing diversity of the cometary dust [2]. We have investigated 3-D structures and elemental distributions of three impact tracks using synchrotron radiation x-ray analyses (microtomography and XRF) as one of the preliminary examination [3]. In this study, additional five tracks were investigated by the same analytical method. Impactor sizes of the tracks were estimated from the track entrance sizes and Fe abundances. Size parameters, such as length, of the tracks were normalized by the impactor size to compare track shape

Iida, Y.↗

Mineralogy, Three Dimensional Structure, and Oxygen Isotope Ratios of Four Crystalline Particles from Comet 81P/Wild 2

Preliminary examinations of small dust particles from comet 82P/Wild 2 revealed many expected and unexpected features. Among them the most striking feature is the presence of abundant crystalline material in the comet. Synchrotron radiation X-ray diffraction and microtomography are the most efficient methods to detect and describe bulk mineralogical features of crystalline cometary particles. In the present study, in addition to these two non-destructive techniques, electron microscopy and ion-probe mass spectrometry were carried out on the four crystalline particles.

Nakamura, T.↗

Application of real-time radiation dosimetry using a new silicon LET sensor

A new type of real-time radiation monitoring device, RRMD-III, consisting of three double-sided silicon strip detectors (DSSDs), has been developed and tested on-board the Space Shuttle mission STS-84. The test succeeded in measuring the linear energy transfer (LET) distribution over the range of 0.2 keV/micrometer to 600 keV/micrometer for 178 h. The Shuttle cruised at an altitude of 300 to 400 km and an inclination angle of 51.6 degrees for 221.3 h, which is equivalent to the International Space Station orbit. The LET distribution obtained for particles was investigated by separating it into galactic cosmic ray (GCR) particles and trapped particles in the South Atlantic Anomaly (SAA) region. The result shows that the contribution in dose-equivalent due to GCR particles is almost equal to that from trapped particles. The total absorbed dose rate during the mission was 0.611 mGy/day; the effective quality factor, 1.64; and the dose equivalent rate, 0.998 mSv/day. The average absorbed dose rates are 0.158 mGy/min for GCR particles and 3.67 mGy/min for trapped particles. The effective quality factors are 2.48 for GCR particles and 1.19 for trapped particles. The absorbed doses obtained by the RRMD-III and a conventional method using TLD (Mg(2)SiO(4)), which was placed around the RRMD-III were compared. It was found that the TLDs showed a lower efficiency, just 58% of absorbed dose registered by the RRMD-III.

NASA Discipline Radiation Health↗

Radiation dosimetry measurements with real time radiation monitoring device (RRMD)-II in Space Shuttle STS-79

The real-time measurement of radiation environment was made with an improved real-time radiation monitoring device (RRMD)-II onboard Space Shuttle STS-79 (S/MM#4: 4th Shuttle MIR Mission, at an inclination angle of 51.6 degrees and an altitude of 250-400km) for 199 h during 17-25 September, 1996. The observation of the detector covered the linear energy transfer (LET) range of 3.5-6000 keV/micrometer. The Shuttle orbital profile in this mission was equivalent to that of the currently planned Space Station, and provided an opportunity to investigate variations in count rate and dose equivalent rate depending on altitude, longitude, and latitude in detail. Particle count rate and dose equivalent rate were mapped geographically during the mission. Based on the map of count rate, an analysis was made by dividing whole region into three regions: South Atlantic Anomaly (SAA) region, high latitude region and other regions. The averaged absorbed dose rate during the mission was 39.3 microGy/day for a LET range of 3.5-6000 keV/micrometer. The corresponding average dose equivalent rates during the mission are estimated to be 293 microSv/day with quality factors from International Commission on Radiological Protection (ICRP)-Pub. 60 and 270 microSv/day with quality factors from ICRP-Pub. 26. The effective quality factors for ICRP-Pub. 60 and 26 are 7.45 and 6.88, respectively. From the present data for particles of LET > 3.5keV/micrometer, we conclude that the average dose equivalent rate is dominated by the contribution of galactic cosmic ray (GCR) particles. The dose-detector depth dependence was also investigated.

manned↗

Measurements of LET distribution and dose equivalent onboard the Space Shuttle IML-2 (STS-65) and S/MM#4 (STS-79)

Space radiation dosimetry measurements have been made onboard the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2: 28.5 degrees x 300 km: 14.68 days) and the STS-79 in the 4th Shuttle MIR mission (S/MM#4: 51.6 degrees x 300-400km: 10.2 days). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD-I for IML-2 and RRMD-II with improved triggering system for S/MM#4)" utilizing silicon semi-conductor detectors and the other detectors are conventional passive detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. The main contribution to dose equivalent for particles with LET > 5.0 keV/micrometer (IML-2) and LET > 3.5 keV/micrometer (S/MM#4) is seen to be due to galactic cosmic rays (GCRs) and the contribution of the South Atlantic Anomaly (SAA) is less than 5% (IML-2: 28.5 degrees x 300 km) and 15% (S/MM#4: 51.6 degrees x 400 km) in the above RRMD LET detection conditions. For the whole LET range (> 0.2 kev/micrometer) obtained by TLDs and CR-39 in these two typical orbits (a small inclination x low altitude and a large inclination x high altitude), absorbed dose rates range from 94 to 114 microGy/day, dose equivalent rates from 186 to 207 microSv/day and average quality factors from 1.82 to 2.00 depending on the locations and directions of detectors inside the Spacelab at the highly protected IML-2 orbit (28.5 degrees x 300 km), and also, absorbed dose rates range from 290 to 367 microGy/day, dose equivalent rates from 582 to 651 microSv/day and average quality factors from 1.78 to 2.01 depending on the dosimeter packages around the RRMD-II "Detector Unit" at the S/MM#4 orbit (5l.6 degrees x 400km). In general, it is seen that absorbed doses depend on the orbit altitude (SAA trapped particles contribution dominant) and dose equivalents on the orbit inclination (GCR contribution dominant). The LET distributions obtained by two different types of active and passive detectors, RRMDs and CR-39, are in good agreement for LET of 15 - 200 kev/micrometer and difference of these distributions in the regions of LET < 15 kev/micrometer and LET > 200 kev/micrometer can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks and chemical etching conditions.

manned↗

Decay of a coherent scalar disturbance in a turbulent flow

The time evolution of an initially coherent, sinusoidal passive-scalar disturbance is considered when the wavelength q is less than the length scale of the surrounding isotropic turbulent flow. In 64 sup 3 direct numerical simulations a Gaussian prescription for the average scalar amplitude breaks down after a timescale associated with the wavenumber of the disturbance and there is a transition to a new characteristic decay. The Gaussian prescription is given by exp(-(1/2) q-squared w(t)), where a form for w(t), the Lagrangian mean square displacement of a single fluid particle, is proposed. After the transition the decay is given by exp(-t/tau), where tau is the new characteristic timescale. If q k(sub K), then 1/tau = 1/tau(sub D) + 1/tau(sub K), where k(sub K) is the Kolmogorov wavenumber, tau(sub D) is the diffusive timescale and tau(sub K) is the Kolmogorov timescale. An experiment originally proposed by de Gennesis considered in which the evolution of a coherent laser-induced pattern is read by a diffracting laser. The theory of this experiment involves the dispersion of particle pairs, but it is shown that in a certain limit it reduces to the single Fourier-mode problem and can be described in terms of single particle diffusion. The decay of a single mode after the transition in the simulation best describes the experiment.

Kerr, R. M.↗

Investigation of air stream from combustor-liner air entry holes, 3

Jets flowing from air entry holes of the combustor liner of a gas turbine were investigated. Cold air was supplied through the air entry holes into the primary hot gas flows. The mass flow of the primary hot gas and issuing jets was measured, and the behavior of the air jets was studied by the measurement of the temperature distribution of the gas mixture. The air jets flowing from three circular air entry holes, single streamwise long holes, and two opposing circular holes, parallel to the primary flow were studied along with the effects of jet and gas stream velocities, and of gas temperature. The discharge coefficient, the maximum penetration of the jets, the jet flow path, the mixing of the jets, and temperature distribution across the jets were investigated. Empirical expressions which describe the characteristics of the jets under the conditions of the experiments were formulated.

Aiba, T.↗