Engineering Papers⌕ Search

Engineering topics

Nakamura, M

Publications and source records attributed to Nakamura, M.

At least 19 records

SU-F-T-230: A Simple Method to Assess Accuracy of Dynamic Wave Arc Irradiation Using An Electronic Portal Imaging Device and Log Files

Purpose: The Dynamic Wave Arc (DWA) technique, where the multi-leaf collimator (MLC) and gantry/ring move simultaneously in a predefined non-coplanar trajectory, has been developed on the Vero4DRT. The aim of this study is to develop a simple method for quality assurance of DWA delivery using an electronic portal imaging device (EPID) measurements and log files analysis. Methods: The Vero4DRT has an EPID on the beam axis, the resolution of which is 0.18 mm/pixel at the isocenter plane. EPID images were acquired automatically. To verify the detection accuracy of the MLC position by EPID images, the MLC position with intentional errors was assessed. Tests were designed considering three factors: (1) accuracy of the MLC position (2) dose output consistency with variable dose rate (160–400 MU/min), gantry speed (2.4–6°/s), ring speed (0.5–2.5°/s), and (3) MLC speed (1.6–4.2 cm/s). All the patterns were delivered to the EPID and compared with those obtained with a stationary radiation beam with a 0° gantry angle. The irradiation log, including the MLC position and gantry/ring angle, were recorded simultaneously. To perform independent checks of the machine accuracy, the MLC position and gantry/ring angle position were assessed using log files. Results: 0.1 mm intentional error can be detected by the EPID, which is smaller than the EPID pixel size. The dose outputs with different conditions of the dose rate and gantry/ring speed and MLC speed showed good agreement, with a root mean square (RMS) error of 0.76%. The RMS error between the detected and recorded data were 0.1 mm for the MLC position, 0.12° for the gantry angle, and 0.07° for the ring angle. Conclusion: The MLC position and dose outputs in variable conditions during DWA irradiation can be easily detected using EPID measurements and log file analysis. The proposed method is useful for routine verification. This research is (partially) supported by the Practical Research for Innovative Cancer Control (15Ack0106151h0001) from Japan Agency for Medical Research and development, AMED. Authors Takashi Mizowaki and Masahiro Hiraoka have consultancy agreement with Mitsubishi Heavy Industries, Ltd., Japan.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-05: Application of a Feature-Based Tracking Algorithm to KV X-Ray Fluoroscopic Images Toward Marker-Less Real-Time Tumor Tracking

Purpose: To detect target position on kV X-ray fluoroscopic images using a feature-based tracking algorithm, Accelerated-KAZE (AKAZE), for markerless real-time tumor tracking (RTTT). Methods: Twelve lung cancer patients treated with RTTT on the Vero4DRT (Mitsubishi Heavy Industries, Japan, and Brainlab AG, Feldkirchen, Germany) were enrolled in this study. Respiratory tumor movement was greater than 10 mm. Three to five fiducial markers were implanted around the lung tumor transbronchially for each patient. Before beam delivery, external infrared (IR) markers and the fiducial markers were monitored for 20 to 40 s with the IR camera every 16.7 ms and with an orthogonal kV x-ray imaging subsystem every 80 or 160 ms, respectively. Target positions derived from the fiducial markers were determined on the orthogonal kV x-ray images, which were used as the ground truth in this study. Meanwhile, tracking positions were identified by AKAZE. Among a lot of feature points, AKAZE found high-quality feature points through sequential cross-check and distance-check between two consecutive images. Then, these 2D positional data were converted to the 3D positional data by a transformation matrix with a predefined calibration parameter. Root mean square error (RMSE) was calculated to evaluate the difference between 3D tracking and target positions. A total of 393 frames was analyzed. The experiment was conducted on a personal computer with 16 GB RAM, Intel Core i7-2600, 3.4 GHz processor. Results: Reproducibility of the target position during the same respiratory phase was 0.6 +/− 0.6 mm (range, 0.1–3.3 mm). Mean +/− SD of the RMSEs was 0.3 +/− 0.2 mm (range, 0.0–1.0 mm). Median computation time per frame was 179 msec (range, 154–247 msec). Conclusion: AKAZE successfully and quickly detected the target position on kV X-ray fluoroscopic images. Initial results indicate that the differences between 3D tracking and target position would be clinically acceptable.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-01: Development of Dynamic Gimbaled X-Ray Head Swing Irradiation Technique

Purpose: The Vero4DRT has a unique gimbaled x-ray head with rotating around orthogonal two axes. The purpose of this study was to develop a new irradiation technique using the dynamic gimbaled x-ray head swing function. Methods: The Vero4DRT has maximum field size of 150Χ150 mm2. The expanded irradiation field (expanded-field) for the longitudinal direction which is vertical to the MLC sliding direction, was created by the MLC motion and the gimbaled x-ray head rotation. The gimbaled x-ray head was rotated ± 35 mm, and the expanded-field size was set as 150Χ220 mm2. To irradiate uniform dose distribution, the diamond-shaped radiation field was created and continuously moved for the longitudinal direction. It was achieved by combination of opening and closing of the MLC and gimbal swing rotation. To evaluate dosimetric characteristic of the expanded-field, films inserted in water-equivalent phantoms at 100 mm depth were irradiated and the field size, penumbra, flatness and symmetry were analyzed.In addition, the expanded-field irradiation technique was applied to virtual wedge irradiation. Wedged beam was acquired with the delta–shaped radiation field. 150Χ 220 mm2 fields with 15, 30, 45, and 60 degree wedge were examined. The wedge angles were measured with irradiated film and compared with assumed wedge angles. Results: The field size, penumbra, flatness and symmetry of the expanded-field were 150.0 mm, 8.1–8.4 mm, 2.8% and −0.8% for the lateral direction and 220.1 mm, 6.3–6.4 mm, 3.2% and −0.4% for the longitudinal direction at 100 mm depth. The measured wedge angles were 15.1, 30.2, 45.2 and 60.2 degrees. The differences between assumed and measured angles were within 0.2 degrees. Conclusion: A new technique of the gimbal swing irradiation was developed. To extend applied targets, especially for whole breast irradiation, the expanded-field and virtual wedge irradiations would be effective.

60 APPLIED LIFE SCIENCES↗

SU-D-207-03: Development of 4D-CBCT Imaging System with Dual Source KV X-Ray Tubes

Purpose: The purposes of this work are to develop 4D-CBCT imaging system with orthogonal dual source kV X-ray tubes, and to determine the imaging doses from 4D-CBCT scans. Methods: Dual source kV X-ray tubes were used for the 4D-CBCT imaging. The maximum CBCT field of view was 200 mm in diameter and 150 mm in length, and the imaging parameters were 110 kV, 160 mA and 5 ms. The rotational angle was 105°, the rotational speed of the gantry was 1.5°/s, the gantry rotation time was 70 s, and the image acquisition interval was 0.3°. The observed amplitude of infrared marker motion during respiration was used to sort each image into eight respiratory phase bins. The EGSnrc/BEAMnrc and EGSnrc/DOSXYZnrc packages were used to simulate kV X-ray dose distributions of 4D-CBCT imaging. The kV X-ray dose distributions were calculated for 9 lung cancer patients based on the planning CT images with dose calculation grid size of 2.5 x 2.5 x 2.5 mm. The dose covering a 2-cc volume of skin (D2cc), defined as the inner 5 mm of the skin surface with the exception of bone structure, was assessed. Results: A moving object was well identified on 4D-CBCT images in a phantom study. Given a gantry rotational angle of 105° and the configuration of kV X-ray imaging subsystems, both kV X-ray fields overlapped at a part of skin surface. The D2cc for the 4D-CBCT scans was in the range 73.8–105.4 mGy. Linear correlation coefficient between the 1000 minus averaged SSD during CBCT scanning and D2cc was −0.65 (with a slope of −0.17) for the 4D-CBCT scans. Conclusion: We have developed 4D-CBCT imaging system with dual source kV X-ray tubes. The total imaging dose with 4D-CBCT scans was up to 105.4 mGy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-351: Verification of Monitor Unit Calculation for Lung Stereotactic Body Radiation Therapy Using a Secondary Independent Planning System

Purpose: To compare isocenter (IC) dose between X-ray Voxel Monte Carlo (XVMC) and Acuros XB (AXB) as part of an independent verification of monitor unit (MU) calculation for lung stereotactic body radiation therapy (SBRT) using a secondary independent treatment planning system (TPS). Methods: Treatment plans of 110 lesions from 101 patients who underwent lung SBRT with Vero4DRT (Mitsubishi Heavy Industries, Ltd., Japan, and BrainLAB, Feldkirchen, Germany) were evaluated retrospectively. Dose distribution was calculated with X-ray Voxel Monte Carlo (XVMC) in iPlan 4.5.1 (BrainLAB, Feldkirchen, Germany) on averaged intensity projection images. A spatial resolution and mean variance were 2 mm and 2%, respectively. The clinical treatment plans were transferred from iPlan to Eclipse (Varian Medical Systems, Palo Alto, CA, USA), and doses were recalculated with well commissioned AXB ver. 11.0.31 while maintaining the XVMC-calculated MUs and beam arrangement. Dose calculations were made in the dose-to-medium dose reporting mode with the calculation grid size of 2.5 mm. The mean and standard deviation (SD) of the IC dose difference between XVMC and AXB were calculated. The tolerance level was defined as |mean|+2SD. Additionally, the relationship between IC dose difference and the size of planning target volume (PTV) or computed tomography (CT) value of internal target volume (ITV) was evaluated. Results: The mean±SD of the IC dose difference between XVMC and AXB was −0.32±0.73%. The tolerance level was 1.8%. Absolute IC dose differences exceeding the tolerance level were observed in 3 patients (2.8%). There were no strong correlations between IC dose difference and PTV size (R=−0.14) or CT value of ITV (R=−0.33). Conclusion: The present study suggested that independent verification of MU calculation for lung SBRT using a secondary TPS is useful.

60 APPLIED LIFE SCIENCES↗

Measurement of the {sup 8}B solar neutrino flux with the KamLAND liquid scintillator detector

We report a measurement of the neutrino-electron elastic scattering rate from {sup 8}B solar neutrinos based on a 123 kton-day exposure of KamLAND. The background-subtracted electron recoil rate, above a 5.5-MeV analysis threshold is 1.49 {+-} 0.14(stat) {+-} 0.17(syst) events per kton-day. Interpreted as due to a pure electron flavor flux with a {sup 8}B neutrino spectrum, this corresponds to a spectrum integrated flux of 2.77 {+-} 0.26(stat) {+-} 0.32(syst) x10{sup 6} cm{sup -2}s{sup -1}. The analysis threshold is driven by {sup 208}Tl present in the liquid scintillator, and the main source of systematic uncertainty is due to background from cosmogenic {sup 11}Be. The measured rate is consistent with existing measurements and with standard solar model predictions which include matter-enhanced neutrino oscillation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-spin states in {sup 188}Au: Further evidence for nonaxial shape

The high-spin level structure of {sup 188}Au has been investigated via the {sup 173}Yb({sup 19}F,4n{gamma}) reaction at beam energies of 86 and 90 MeV. The previously reported level scheme has been modified and extended significantly. A new I{sup {pi}}=20{sup +} state associated with {pi}h{sub 11/2}{sup -1} x {nu}i{sub 13/2}{sup -2}h{sub 9/2}{sup -1} configuration and two new rotational bands, one of which is built on the {pi}h{sub 9/2} x {nu}i{sub 13/2} configuration, have been identified. The prolate-to-oblate shape transition through triaxial shape has been proposed to occur around {sup 188}Au for the {pi}h{sub 9/2} x {nu}i{sub 13/2} bands in odd-odd Au isotopes. Evidence for {pi}h{sub 11/2}{sup -1} x {nu}i{sub 13/2}{sup -1} structure of nonaxial shape with {gamma}<-70 deg. has been obtained by comparison with total Routhian surface and cranked-shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Production of radioactive isotopes through cosmic muon spallation in KamLAND

Radioactive isotopes produced through cosmic muon spallation are a background for rare-event detection in nu detectors, double-beta-decay experiments, and dark-matter searches. Understanding the nature of cosmogenic backgrounds is particularly important for future experiments aiming to determine the pep and CNO solar neutrino fluxes, for which the background is dominated by the spallation production of {sup 11}C. Data from the Kamioka liquid-scintillator antineutrino detector (KamLAND) provides valuable information for better understanding these backgrounds, especially in liquid scintillators, and for checking estimates from current simulations based upon MUSIC, FLUKA, and GEANT4. Using the time correlation between detected muons and neutron captures, the neutron production yield in the KamLAND liquid scintillator is measured to be Y{sub n}=(2.8+-0.3)x10{sup -4} mu{sup -1} g{sup -1} cm{sup 2}. For other isotopes, the production yield is determined from the observed time correlation related to known isotope lifetimes. We find some yields are inconsistent with extrapolations based on an accelerator muon beam experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of the Production of Radioactive Isotopes through Cosmic Muon Spallation in KamLAND

Radioactive isotopes produced through cosmic muon spallation are a background for rare event detection in {nu} detectors, double-beta-decay experiments, and dark-matter searches. Understanding the nature of cosmogenic backgrounds is particularly important for future experiments aiming to determine the pep and CNO solar neutrino fluxes, for which the background is dominated by the spallation production of {sup 11}C. Data from the Kamioka Liquid scintillator Anti-Neutrino Detector (KamLAND) provides valuable information for better understanding these backgrounds, especially in liquid scintillator, and for checking estimates from current simulations based upon MUSIC, FLUKA, and Geant4. Using the time correlation between detected muons and neutron captures, the neutron production yield in the KamLAND liquid scintillator is measured to be (2.8 {+-} 0.3) x 10{sup -4} n/({mu} {center_dot} (g/cm{sup 2})). For other isotopes, the production yield is determined from the observed time correlation related to known isotope lifetimes. We find some yields are inconsistent with extrapolations based on an accelerator muon beam experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurement of Neutrino Oscillation Parameters with KamLAND

The KamLAND experiment has determined a precise value for the neutrino oscillation parameter {delta}m{sub 21}{sup 2} and stringent constraints on {theta}{sub 12}. The exposure to nuclear reactor antineutrinos is increased almost fourfold over previous results to 2.44x10{sup 32} proton yr due to longer livetime and an enlarged fiducial volume. An undistorted reactor {nu}{sub e} energy spectrum is now rejected at >5{sigma}. Analysis of the reactor spectrum above the inverse beta decay energy threshold, and including geoneutrinos, gives a best fit at {delta}m{sub 21}{sup 2}=7.58{sub -0.13}{sup +0.14}(stat){sub -0.15}{sup +0.15}(syst)x10{sup -5}= eV{sup 2} and tan{sup 2}{theta}{sub 12}=0.56{sub -0.07}{sup +0.10}(stat){sub -0.06}{sup +0.10}(syst). Local {delta}{chi}{sup 2} minima at higher and lower {delta}m{sub 21}{sup 2} are disfavored at >4{sigma}. Combining with solar neutrino data, we obtain {delta}m{sub 21}{sup 2}=7.59{sub -0.21}{sup +0.21}x10{sup -5} eV{sup 2} and tan{sup 2}{theta}{sub 12}=0.47{sub -0.05}{sup +0.06}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-thermal processes in standard big bang nucleosynthesis: I. In-flight nuclear reactions induced by energetic protons

The standard model of big bang nucleosynthesis (BBN) relies on a nuclear reaction network operating with thermal reactivities for Maxwellian plasma. In the primordial plasma, however, a number of non-thermal processes triggered by energetic particles of various origins can take place. In the present work we examine in-flight nuclear reactions induced in the plasma by MeV protons generated in D(d, p)T and {sup 3}He(d, p){sup 4}He fusions. We particularly focus on several low threshold endoergic processes. These are reactions omitted in the standard network-proton-induced break-ups of loosely bound D, {sup 7}Li, {sup 7}Be nuclei-and the {sup 3}H(p, n){sup 3}He charge-exchange reaction important for the interconversion of A = 3 nuclei in the early universe. It is found that the break-up processes in the plasma take the form of Maxwellian processes at temperatures T>70 keV, while in the lower temperature range they proceed as non-thermal reactions. It is shown that at T<70 keV the in-flight reaction channels can enhance the break-up reactivities by several orders of magnitude. The levels of these reactivities however remain insufficiently high to affect BBN kinetics and change the standard prediction of light element abundances. The abundances are found to be: Y{sub p} = 0.2457, D/H = 2.542 Multiplication-Sign 10{sup -5}, {sup 3}He/H = 1.004 Multiplication-Sign 10{sup -5}, {sup 7}Li/H = 4.444 Multiplication-Sign 10{sup -10}. Future steps in the study of non-thermal processes in the primordial plasma are briefly discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel Internal Target for Electron Scattering off Unstable Nuclei

A novel internal target has been developed, which will make electron scattering off short-lived radioactive nuclei possible in an electron storage ring. An 'ion trapping' phenomenon in the electron storage ring was successfully utilized for the first time to form the target for electron scattering. Approximately 7x10{sup 6} stable {sup 133}Cs ions were trapped along the electron beam axis for 85 ms at an electron beam current of 80 mA. The collision luminosity between the stored electrons and trapped Cs ions was determined to be 2.4(8)x10{sup 25} cm{sup -2} s{sup -1} by measuring elastically scattered electrons.

43 PARTICLE ACCELERATORS↗

Wolfenstein parameters for s{sub 1/2} proton knockout (p,2p) reactions

A complete set of Wolfenstein parameters (D{sub i{sup '}}{sub j}), induced polarizations (P), and analyzing powers (A{sub y}) have been measured for (p,2p) reactions on {sup 6}Li, {sup 12}C, and {sup 40}Ca targets in order to investigate possible nuclear medium effects on the nucleon-nucleon (NN) interaction. Most of these observables show significant reductions from the values for proton-proton scattering as monotonic functions of the nuclear density relevant to these reactions. The reductions of these D{sub i{sup '}}{sub j} are reasonably reproduced by nonrelativistic plane-wave and distorted-wave calculations based on the impulse approximation, demonstrating that these suppressions are attributed to changes of the two body kinematics due to the finite separation energies of these reactions, while the reductions of A{sub y} and P are much more prominent than the calculations. The relativistic calculations, which partly explain the A{sub y} and P reductions, cannot reproduce the D{sub i{sup '}}{sub j} data, but all the data are consistently reproduced when the parameters of the NN interaction in a meson exchange model are renormalized, suggesting possible modifications of the NN interaction by the surrounding nuclear medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of Hydrogen Isotope Geochemistry to Volcanology: Recent Perspective on Eruption Dynamics

Degassing of magma is central to understand the dynamics of volcanic eruption. Hydrogen isotopic composition of volcanic rocks reflects degassing processes. The natural obsidian samples in some eruptions typically show a gently and then rapidly decreasing {delta}D trends with decreasing water content; this led to the two-stage degassing model, with closed-system volatile exsolution (batch fractionation of hydrogen isotope) during the explosive phase followed by open-system degassing (Rayleigh fractionation) to produce the low {delta}D value of the dome and flow lavas. However, the relationship between pattern of degassing (and fractionation) and mode of eruption is controversial. Based on the CO{sub 2}/H{sub 2}O ratio of the obsidians, Rust et al. suggested that the analyzed samples with relatively constant {delta}D value and high water content were buffered (re-equilibrated) with vapor of relatively constant isotopic composition, assuming that silicic magma along conduit wall is fragmented and highly permeable. However, the timing and mechanism of the shift to open system degassing (Rayleigh fractionation) has not been clarified. To further constrain the eruption dynamics, experimental study on the hydrogen isotope fractionation during degassing would be helpful, although common noble metals used as sample capsules, including Au, are permeable to hydrogen at magmatic temperature, and even to water molecule in the prolonged run, probably due to the change of grain boundary properties such as thermal grooving.

58 GEOSCIENCES↗

OPERA - First Beam Results

OPERA is a long base-line neutrino oscillation experiment to detect tau-neutrino appearance and to prove that the origin of the atmospheric muon neutrino deficit observed by Kamiokande is the neutrino oscillation. A Hybrid emulsion detector, of which weight is about 1.3 kton, has been installed in Gran Sasso laboratory. New muon neutrino beam line, CNGS, has been constructed at CERN to send neutrinos to Gran Sasso, 730 km apart from CERN. In 2006, first neutrinos were sent from CERN to LNGS and were detected by the OPERA detector successfully as planned.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗