Engineering Papers⌕ Search

Engineering topics

Nakamura, K

Publications and source records attributed to Nakamura, K.

At least 55 records · Page 3

Desulfurization Reactions on Surfaces of Metal Carbides: Photoemission and Density-Functional Studies

High-resolution photoemission and density functional (DF) calculations were used to study the interaction of atomic sulfur and S-containing molecules with metal carbides in which the carbon/metal ratio varies from 0.5 to 1 (M2C and MC, M = Ti, V or Mo). In these compounds, the C sites cannot be considered as simple spectators. They moderate the reactivity of the metal centers and provide bonding sites for adsorbates. For example, the adsorption of S on TiC(001) induces a large positive shift (1.0-1.3 eV) in the C 1s core level. DF calculations give a CTiTi hollow as the most stable site for the S adatoms. There is a correlation between the adsorption energy of S or thiophene and shifts in the centroid of the metal d band induced by metal-carbon bonding in the metal carbides. The M2C and MC carbides have difficulty obeying Sabatier's principle for being good HDS catalysts because some of them interact too strongly with the products (M2C stoichiometry) and the others have problems dissociating the reactants (MC stoichiometry). The addition of small Au nanoparticles is an efficient way for enhancing the HDS activity of MC catalysts. In spite of the very poor desulfurization performance of TiC and MoC, the Au/TiC and Au/MoC systems display an HDS activity comparable or higher than that of conventional Ni/MoS{sub x} catalysts. The Au nanoparticles probably increase the HDS activity of the metal carbides by enhancing the adsorption energy of thiophene and by helping in the dissociation of H2 to produce the hydrogen necessary for the hydrogenolysis of C-S bonds and the removal of sulfur.

08 HYDROGEN↗

Outward electron orbit extending to inward part of closed helical magnetic surfaces surrounded by shifted negative space potential

Outward electron orbits that extend to the inward part of a closed helical vacuum magnetic region are found in three-dimensional calculations, which take into account two experimental findings. The pitch angle of electrons in the stochastic magnetic region (SMR) is scattered considerably due to the presence of a shifted self-space potential phi{sub s}. Eventually, the electron becomes a helically trapped particle, and starts an inward movement along one of the |B{sub min}| contours. Once penetrating into the helical magnetic region, the electron is never lost to the chamber wall, because the negative phi{sub s} in the SMR acts as a potential barrier.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of Au-C Interactions on the Catalytic Activity of Au Nanoparticles Supported on TiC(001) Towards Molecular Oxygen Dissociation

High-resolution photoemission and density functional calculations on realistic slab surface models were used to study the interaction and subsequent dissociation of O{sub 2} with Au nanoparticles supported on TiC(001). The photoemission results indicate that at 150 K O{sub 2} adsorbs molecularly on the supported gold nanoparticles, and upon heating to temperatures above 200 K the O{sub 2} {yields} 2O reaction takes place with migration of atomic oxygen to the TiC(001) substrate. The addition of Au to TiC(001) substantially enhances the rate of O{sub 2} dissociation at room temperature. The reactivity of Au nanoparticles supported on TiC(001) toward O{sub 2} dissociation is much larger than that of similar nanoparticles supported either on TiO{sub 2}(110) or MgO(001) surfaces, where the cleavage of O-O bonds is very difficult. Density functional calculations carried out on large supercells show that the contact of Au with TiC(001) is essential for charge polarization and an enhancement in the chemical activity of Au. Small two-dimensional particles which expose Au atoms in contact with TiC(001) are the most reactive. While O{sub 2} prefers binding to Au sites, the O atoms interact more strongly with the TiC(001) surface. The oxygen species active during the low-temperature (<200 K) oxidation of carbon monoxide on Au/TiC(001) is chemisorbed O{sub 2}. Once atomic O binds to TiC(001), the chemisorption bond is so strong that temperatures well above 400 K are necessary to remove the O adatoms from the TiC(001) substrate by direct reaction with CO. The high reactivity of Au/TiC(001) toward O{sub 2} at low-temperature opens the route for the transformation of alcohols and amines on the supported Au nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Percutaneous Radiofrequency Lung Ablation Combined with Transbronchial Saline Injection: An Experimental Study in Swine

To evaluate the efficacy of radiofrequency lung ablation with transbronchial saline injection. The bilateral lungs of eight living swine were used. A 13-gauge bone biopsy needle was inserted percutaneously into the lung, and 1 ml of muscle paste was injected to create a tumor mimic. In total, 21 nodules were ablated. In the saline injection group (group A), radiofrequency ablation (RFA) was performed for 11 nodules after transbronchial saline injection under balloon occlusion with a 2-cm active single internally cooled electrode. In the control group (group B), conventional RFA was performed for 10 nodules as a control. The infused saline liquid showed a wedge-shaped and homogeneous distribution surrounding a tumor mimic. All 21 RFAs were successfully completed. The total ablation time was significantly longer (13.4 {+-} 2.8 min vs. 8.9 {+-} 3.5 min; P = 0.0061) and the tissue impedance was significantly lower in group A compared with group B (73.1 {+-} 8.8 {Omega} vs. 100.6 {+-} 16.6 {Omega}; P = 0.0002). The temperature of the ablated area was not significantly different (69.4 {+-} 9.1{sup o}C vs. 66.0 {+-} 7.9{sup o}C; P = 0.4038). There was no significant difference of tumor mimic volume (769 {+-} 343 mm{sup 3} vs. 625 {+-} 191 mm{sup 3}; P = 0.2783). The volume of the coagulated area was significantly larger in group A than in group B (3886 {+-} 1247 mm{sup 3} vs. 2375 {+-} 1395 mm{sup 3}; P = 0.0221). Percutaneous radiofrequency lung ablation combined with transbronchial saline injection can create an extended area of ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging Single Atoms Using Secondary Electrons with an Aberration-Corrected Electron Microscope

Aberration correction has embarked on a new frontier in electron microscopy by overcoming the limitations of conventional round lenses, providing sub-angstrom-sized probes. However, improvement of spatial resolution using aberration correction so far has been limited to the use of transmitted electrons both in scanning and stationary mode, with an improvement of 20-40%. In contrast, advances in the spatial resolution of scanning electron microscopes (SEMs), which are by far the most widely used instrument for surface imaging at the micrometre-nanometre scale, have been stagnant, despite several recent efforts. Here, we report a new SEM, with aberration correction, able to image single atoms by detecting electrons emerging from its surface as a result of interaction with the small probe. The spatial resolution achieved represents a fourfold improvement over the best-reported resolution in any SEM. Furthermore, we can simultaneously probe the sample through its entire thickness with transmitted electrons. This ability is significant because it permits the selective visualization of bulk atoms and surface ones, beyond a traditional two-dimensional projection in transmission electron microscopy. It has the potential to revolutionize the field of microscopy and imaging, thereby opening the door to a wide range of applications, especially when combined with simultaneous nanoprobe spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the Production of Radioactive Isotopes through Cosmic Muon Spallation in KamLAND

Radioactive isotopes produced through cosmic muon spallation are a background for rare event detection in {nu} detectors, double-beta-decay experiments, and dark-matter searches. Understanding the nature of cosmogenic backgrounds is particularly important for future experiments aiming to determine the pep and CNO solar neutrino fluxes, for which the background is dominated by the spallation production of {sup 11}C. Data from the Kamioka Liquid scintillator Anti-Neutrino Detector (KamLAND) provides valuable information for better understanding these backgrounds, especially in liquid scintillator, and for checking estimates from current simulations based upon MUSIC, FLUKA, and Geant4. Using the time correlation between detected muons and neutron captures, the neutron production yield in the KamLAND liquid scintillator is measured to be (2.8 {+-} 0.3) x 10{sup -4} n/({mu} {center_dot} (g/cm{sup 2})). For other isotopes, the production yield is determined from the observed time correlation related to known isotope lifetimes. We find some yields are inconsistent with extrapolations based on an accelerator muon beam experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Longitudinal Density Tailoring for the Enhancement of Electron Beams in theCapillary-discharge Laser-guidedWakefield Accelerator

Density perturbations in a hydrogen-filled capillary discharge waveguide have been used to control the injection of electrons into a laser wakefield. This has allowed injection and acceleration in channels of lower density than previously possible, and the production of relativistic electron beams with improved stability. For parameters of optimum stability, the mean bunch energy was 300MeV +- 7 MeV rms, with divergence 1.3 mrad +- 0:1 mrad rms and pointing stability 0.8 mrad rms.

43 PARTICLE ACCELERATORS↗

Experimental study of self-trapping in capillary discharge guided laser wakefield acceleration

Laser wakefield acceleration experiments were carried out using hydrogen-filled capillary discharge waveguides. For a 33 mm long, 300 mu m capillary, parameter regimes with high energy electron beams (up to 1 GeV) and stable 0.5 GeV were found. In the high energy regime, the electron beam peak energy was correlated with the number of trapped electrons. For a 15 mm long, 200 mu m diameter capillary, quasi-monoenergetic e beams up to 300 MeV were observed. By de-tuning discharge delay from optimum guiding performance, self-trapping was found to be stabilized.

43 PARTICLE ACCELERATORS↗

UNDULATOR-BASED LASER WAKEFIELD ACCELERATOR ELECTRON BEAM DIAGNOSTIC

to couple the THUNDER undulator to the LOASIS Lawrence Berkeley National Laboratory (LBNL) laser wakefield accelerator (LWFA). Currently the LWFA has achieved quasi-monoenergetic electron beams with energies up to 1 GeV. These ultra-short, high-peak-current, electron beams are ideal for driving a compact XUV free electron laser (FEL). Understanding the electron beam properties such as the energy spread and emittance is critical for achieving high quality light sources with high brightness. By using an insertion device such as an undulator and observing changes in the spontaneous emission spectrum, the electron beam energy spread and emittance can be measured with high precision. The initial experiments will use spontaneous emission from 1.5 m of undulator. Later experiments will use up to 5 m of undulator with a goal of a high gain, XUV FEL.

43 PARTICLE ACCELERATORS↗

Progress on laser plasma accelerator development using transverselyand longitudinally shaped plasmas

A summary of progress at Lawrence Berkeley National Laboratory is given on: (1) experiments on down-ramp injection; (2) experiments on acceleration in capillary discharge plasma channels; and (3) simulations of a staged laser wakefield accelerator (LWFA). Control of trapping in a LWFA using plasma density down-ramps produced electron bunches with absolute longitudinal and transverse momentum spreads more than ten times lower than in previous experiments (0.17 and 0.02 MeV Ic FWHM, respectively) and with central momenta of 0.76 +- 0.02 MeV Ic, stable over a week of operation. Experiments were also carried out using a 40 TW laser interacting with a hydrogen-filled capillary discharge waveguide. For a 15 mm long, 200 mu m diameter capillary, quasi-monoenergetic bunches up to 300 MeV were observed. By detuning discharge delay from optimum guiding performance, self-trapping was found to be stabilized. For a 33 mm long, 300 mu m capillary, a parameter regime with high energy bunches, up to 1 Ge V, was found. In this regime, peak electron energy was correlated with the amount of trapped charge. Simulations show that bunches produced on a down-ramn and iniected into a channel-guided LWFA can produce stable beams with 0.2 MeV Ic-class momentum spread at high energies.

43 PARTICLE ACCELERATORS↗

Recent Progress on Toroidal Nonneutral Plasmas Confined on Heliotron Magnetic Surfaces

Firstly, non-constant space potential {phi}{sub s} and electron density n{sub e} on magnetic surfaces of helical nonneutral plasmas are observed in CHS experiments. The variation of {phi}{sub s} has grown with increasing electron injection energy, implying that thermal effects are important when considering the force balance along magnetic field lines. These observations confirm the existence of plasma equilibrium having non-constant {phi}{sub s} and n{sub e} on magnetic surfaces of helical nonneutral plasmas. Secondly, outward orbits that extend to inward part of closed helical vacuum magnetic region are found in three dimensional calculations which take into account two experimental findings. The pitch angle of electron injected into the stochastic magnetic region is scattered considerably due to the presence of shifted self space potential {phi}{sub s}. Eventually, the injected electron turns to be a helically trapped particle, and start an inward movement along one of the |B{sub min}| contours. Once penetrating deeply, the electron can never escape from the last closed flux surface because the negative {phi}{sub s} acts as a potential barrier. Thirdly, first data obtained from toroidal nonneutral plasmas confined on the quasi-poloidally symmetric magnetic surfaces having a helical-axis is described. It shows that externally produced plasmas are successfully observed, and moreover, the non-constant {phi}{sub s} and n{sub e} of helical nonneutral plasmas are ensured in the Heliotron J experiments, as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Creation of a Tumor-Mimic Model Using a Muscle Paste for Radiofrequency Ablation of the Lung

The purpose of this study was to develop an easily created tumor-mimic model and evaluate its efficacy for radiofrequency ablation (RFA) of the lung. The bilateral lungs of eight living adult swine were used. A tumor-mimic model was made by percutaneous injection of 1.0 ml muscle paste through the bone biopsy needle into the lung. An RFA probe was then inserted into the tumor mimics immediately after tumor creation. Ablation time, tissue impedance, and temperature were recorded. The tumor mimics and their coagulated regions were evaluated microscopically and macroscopically. The muscle paste was easily injected into the lung parenchyma through the bone biopsy needle and well visualized under fluoroscopy. In 10 of 12 sites the tumor mimics were oval shaped, localized, and homogeneous on gross specimens. Ten tumor mimics were successfully ablated, and four locations were ablated in the normal lung parenchyma as controls. In the tumor and normal lung parenchyma, ablation times were 8.9 {+-} 3.5 and 4.4 {+-} 1.6 min, respectively; tissue impedances at the start of ablation were 100.6 {+-} 16.6 and 145.8 {+-} 26.8 {Omega}, respectively; and temperatures at the end of ablation were 66.0 {+-} 7.9 and 57.5 {+-} 7.6{sup o}C, respectively. The mean size of tumor mimics was 13.9 x 8.2 mm, and their coagulated area was 18.8 x 13.1 mm. In the lung parenchyma, the coagulated area was 15.3 x 12.0 mm. In conclusion, our tumor-mimic model using muscle paste can be easily and safely created and can be ablated using the ablation algorithm in the clinical setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The KamLAND Full-Volume Calibration System

We have successfully built and operated a source deployment system for the KamLAND detector. This system was used to position radioactive sources throughout the delicate 1-kton liquid scintillator volume, while meeting stringent material cleanliness, material compatibility, and safety requirements. The calibration data obtained with this device were used to fully characterize detector position and energy reconstruction biases. As a result, the uncertainty in the size of the detector fiducial volume was reduced by a factor of two. Prior to calibration with this system, the fiducial volume was the largest source of systematic uncertainty in measuring the number of antineutrinos detected by KamLAND. This paper describes the design, operation and performance of this unique calibration system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma gradient controlled injection and postacceleration of high quality electron bunches

Plasma density gradient control of wake phase velocity and trapping threshold in a laser wakefield accelerator produced electron bunches with absolute longitudinal and transverse momentum spreads more than ten times lower than in previous experiments (0.17 and 0.02 MeV/c FWHM, respectively) and with central momenta of 0.76{+-}0.02 MeV/c, stable over a week of operation. Simulations validated against diagnostics show that use of such bunches as a wakefield accelerator injector can produce stable beams with 0.2 MeV/c-class momentum spread at high energies. Preservation of bunch momentum spread requires high simulation momentum accuracy, and related self-trapped simulations showed that high order particle weight effectively suppresses simulation momentum errors allowing design of low emittance stages.

43 PARTICLE ACCELERATORS↗

Analysis of Capillary Guided Laser Plasma Accelerator Experiments at LBNL

Laser wakefield acceleration experiments were carried out by using a hydrogen-filled capillary discharge waveguide. For a 15 mm long, 200 {mu}m diameter capillary, quasi-monoenergetic e-beams up to 300 MeV were observed. By de-tuning discharge delay from optimum guiding performance, self-trapping was found to be stabilized. For a 33 mm long, 300 {mu}m capillary, a parameter regime with high energy electron beams, up to 1 GeV, was found. In this regime, the electron beam peak energy was correlated with the amount of trapped electrons.

43 PARTICLE ACCELERATORS↗

Staging Laser Plasma Accelerators for Increased Beam Energy

Staging laser plasma accelerators is an efficient way of mitigating laser pump depletion in laser driven accelerators and necessary for reaching high energies with compact laser systems. The concept of staging includes coupling of additional laser energy and transporting the electron beam from one accelerating module to another. Due to laser damage threshold constraints, in-coupling laser energy with conventional optics requires distances between the accelerating modules of the order of 10 m, resulting in decreased average accelerating gradient and complicated e-beam transport. In this paper we use basic scaling laws to show that the total length of future laser plasma accelerators will be determined by staging technology. We also propose using a liquid jet plasma mirror for in-coupling the laser beam and show that it has the potential to reduce distance between stages to the cm-scale.

43 PARTICLE ACCELERATORS↗

Free-electron laser driven by the LBNL laser-plasma accelerator

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by a high-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source ({approx}10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (> or approx.10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10{sup 13} photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

43 PARTICLE ACCELERATORS↗

Desulfurization of Thiophene on Au/TiC(001): Au−C Interactions and Charge Polarization

Photoemission and first-principles DF calculations were used to study the interaction of thiophene with TiC(001) and Au/TiC(001) surfaces. The adsorption strength of thiophene on TiC(001) is weak, and the molecule desorbs at temperatures below 200 K. The molecule binds to Ti centers of TiC(001) through its sulfur atom with negligible structural perturbations. In spite of the very poor desulfurization performance of TiC(001) or Au(111), a Au/TiC(001) system displays a hydrodesulfurization activity higher than that of conventional Ni/MoS{sub x} catalysts. The Au?TiC(001) interactions induce a polarization of electron density around Au which substantially increases the chemical reactivity of this metal. Au nanoparticles drastically increase the hydrodesulfurization activity of TiC(001) by enhancing the bonding energy of thiophene and by helping in the dissociation of H{sub 2} to produce the hydrogen necessary for the hydrogenolysis of C-S bonds and the removal of sulfur. H{sub 2} spontaneously dissociates on small two-dimensional clusters of gold in contact with TiC(001). On these systems, the adsorption energy of thiophene is 0.45-0.65 eV larger than that on TiC(001) or Au(111). Thiophene binds in a ?5 configuration with a large elongation ({approx}0.2 {angstrom}) of the C-S bonds.

08 HYDROGEN↗