Engineering Papers⌕ Search

Engineering topics

Muscatello, C. M.

Publications and source records attributed to Muscatello, C. M..

Numerical modeling of pedestal stability and broadband turbulence of wide-pedestal QH-mode plasmas on DIII-D

The wide-pedestal quiescent high confinement mode discovered on DIII-D in recent years is a stationary and quiescent H-mode (QH-mode) with the pedestal width exceeding EPED prediction by at least 25%. Its characteristics, such as low rotation, high energy confinement and edge localized mode-free operation, make it an attractive operation mode for future reactors. Linear and nonlinear simulations using BOUT++ reduced two fluid MHD models and awere carried out to investigate the bursty broadband turbulence often observed in the edge of wide-pedestal QH-mode plasmas. Two kinds of MHD-scale instabilities in different spatial locations within the pedestal were found in the simulations: one mild peeling–ballooning (PB) mode γ PB < 0.04ω A ) located near the minimum in E r</:sub> well propagating in ion diamagnetic drift direction; and one drift-Alfvén wave locates at smaller radius compared to E r</:sub> well propagating in the electron diamagnetic drift direction and unstable only when the parallel electron dynamics is included in the simulation. The coupling between drift wave and shear Alfvén wave provides a possible cause of the experimentally observed local profile flattening in the upper-pedestal. The rotation direction, mode location, as well as the wavenumber of these two modes from BOUT++ simulations agree reasonably well with the experimental measurements, while the lack of quantitative agreement is likely due to the lack of trapped electron physics in current fluid model. This work presents improved physics understanding of the pedestal stability and turbulence dynamics for wide-pedestal QH-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast wave interferometer for ion density measurement on DIII-D

=A fast wave interferometer (FWI), which can measure ion mass density, has been developed on DIII-D for its use on future fusion reactors, as well as for the study of ion behavior in current plasma devices. The frequency of the fast waves used for the FWI is around 60 MHz, and require antennas and coaxial cables or waveguides, which, unlike traditional mirror-based optical interferometers, are less susceptible to neutron/gamma-ray radiation and are relatively immune to impurity deposition and erosion as well as alignment issues. The bulk ion density evaluated using FWI show good agreement with that derived from CO 2 interferometry within about 15%. When the ion mass density measurement by FWI is combined with an electron density measurement from CO 2 interferometry, Z eff measurements are also enabled and are in agreement with those from visible Bremsstrahlung measurements. Additionally, large-bandwidth FWI measurements clearly resolve 10–100 kHz coherent modes and demonstrate its potential as a core fluctuation diagnostic, sensitive to both magnetic and ion density perturbations.

Instruments & Instrumentation↗

Development of a narrow stopband filter for spectroscopic fast ion deuterium-alpha measurements

A new technique to attenuate the unshifted deuterium Balmer-alpha (D-alpha) emission is developed and tested for the fast ion D-alpha (FIDA) diagnostic. The unshifted D-alpha emission, at λ = 656.1 nm, is around three orders of magnitude higher than the desired FIDA emission. Blocking the strong emission feature is essential to prevent blooming and light smearing on the CCD chip and scattered light contamination. The new method is a notch filter approach that utilizes the reflection from ultra-narrow bandpass filters to block the saturating signal before it enters the spectrometer. Collimated light from the fibers is reflected off the filter at a 15° angle of incidence. Measurements show that a center wavelength transmission of 0.006 and a blocking full width at half maximum of ~ 1 nm are achieved by using a 200 μm fiber and a 20 mm focal length collimator with two filters.

47 OTHER INSTRUMENTATION↗

Performance demonstration of vacuum microwave components critical for the operation of the ITER low-field side reflectometer

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

47 OTHER INSTRUMENTATION↗