Engineering Papers⌕ Search

Engineering topics

Murphy, Mark K

Publications and source records attributed to Murphy, Mark K.

Gamma Radiation Effects on Physical, Optical, and Structural Properties of Binary As-S glasses

Gamma radiation induces changes in physical, optical, and structural properties in chalcogenide glasses., Previous research has focused on As{sub 2}S{sub 3} and families of glasses containing Ge. For the first time, we present composition and dose dependent data on the As-S binary glass series. Binary As{sub x}S{sub 100-x} (x = 30, 33, 36, 40, and 42) glasses were irradiated with gamma radiation using a {sup 60}Co source at 2.8 Gy/s to accumulated doses of 1, 2, 3, and 4 MGy. The irradiated samples were characterized at each dose level for density, refractive index, x-ray diffraction, and Raman spectrum. These results are compared to those of as-made and 1 year aged samples. We report an initial increase in density followed by a decrease as a function of dose that contradicts the expected compositional dependence of molar volume of these glasses. This unusual behavior is explained based on microvoid formation and nanoscale phase-separation induced by the irradiation in these glasses. XRD, Raman, and EPR data provide supporting evidence, underscoring the importance of optimally- or overly-constrained structures for stability under aging or irradiation.

36 MATERIALS SCIENCE↗

INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS

Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125°C and a more stable peak around 225°C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry–the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an interrogation tool to provide enhanced pathway information on interdicted or newly discovered waste containers of unknown origin or history by considering the total absorbed dose received by a container in tandem with the physical characteristics of the radioactive material housed within that container. One hypothetical scenario is presented to illustrate the application of intrinsic dosimetry to waste management and nuclear forensics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Intrinsic dosimetry of glass containers used to transport nuclear materials: Potential implications to the fields of waste management and nuclear forensics

Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 min to w60 days following exposure to a dose of up to 100 Gy. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 0.5 and 1 Gy. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and no significant variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of 3.3 Gy, a 100 Gy dose would still be detected 2.7E3 years after exposure. Here, we introduce the concept of intrinsic dosimetry, the measurement of the total absorbed dose received by the walls of a container containing radioactive material. The foreseen advantage of intrinsic dosimetry comes from considering the measured absorbed dose received by containers in concert with the characteristics (amount, type) of the source of that dose, the radioactive material contained within the walls of the container, in order to provide enhanced information about the history of an unknown sample in question. Three hypothetical scenarios are presented to introduce this method and to illustrate how intrinsic dosimetry might benefit the fields of nuclear forensics and waste management.

glass↗

INTRINSIC DOSIMETRY OF GLASS CONTAINERS USED TO TRANSPORT NUCLEAR MATERIALS: Potential Implications to the Field of Nuclear Forensics

Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to ~60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110oC, 205oC, and 225oC. The intensity of the 205oC peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205oC peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of 330 Rad, a 10,000 Rad dose would still be detected 2.7E3 years after exposure. This paper introduces the concept of intrinsic dosimetry, the consideration of a measured dose received to container walls in concert with the physical characteristics of the radioactive material contained inside those walls, as a method for gathering rather unique pathway information about the history of that sample. Three hypothetical scenarios are presented to introduce this method and to illustrate how intrinsic dosimetry might benefit the fields of nuclear forensics and waste management.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Exposure Facility Technical Description

The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."

07 ISOTOPE AND RADIATION SOURCES↗